Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹28.6 L
EMD Value
₹57,300
Closing Date
9 Aug 2021, 6:00 pmClosed
GARRISON ENGINEER ARMY UTILITY JODHPUR
GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR
REPAIR / MAINTENANCE OF SEWAGE PUMPS AND PANELS AND CLEANING OF SEWAGE UG SUMPS AND INSTALLATIONS AND ALLIED WORKS IN ARMY AREA JODHPUR
2021_MES_449354_1
8981/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER ARMY UTILITY MULTAN LINE JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER ARMY UTILITY JODHPUR
₹57,300
Yes
24 Aug 2021
7 Jun 2021
16 Aug 2021
7 Jun 2021
9 Aug 2021
22 Jun 2021
Amount
Lifting/ lowering of non clog sewage submersible pump set of the capacity 225 cum/hr, head 20 meter speed 1450 RPM Model No KRTK 150-315/234 UG1-S make KSB from the Raw Sewage sump of depth 40 feet Lifting : Disconnection of outgoing delivery mains and eletrical connection from the panel and dewatering the STP main receiving sump with in the time period for easy working and should be provide suitable pumps for lifting of raw sewage water from 40 ft depth, pumps out let should be connected with existing header, after dewatering, lifting of unserviceable non clog sewage submersible pump set of any depth alongwith column pipe/ without column pipe, SWR rope including existing submersible cable and check the unserviceability,remove the sludge/ poly bags/ cement bags/any solid items from inside the pump bowel/impellor and make good working condition with all safetyes etc complete all as directed. Lowering :- Lowering the non clog sewage submersible pump after making operational condition alongwith column pipe/ without column pipe, SWR rope including existing submersible cable and all respective items here-in- above lifting and installation of pump motor in its original position, connections as well as delivery main including electrical connectiion of both end i.e. with starter and motor terminals. Note :- (a) Rate quoted against items deemed to be included for lifting /lowering. (b) lifting equipments like crane/Chain pulley block/fork lift etc will be used according to the load of pump alongwith column pipe and connected items. (c) Any damages to equipment due to negligence of contractor employees during lifting/lowering to be born by contractor at this own risk & cost as per direction of Engr-in- Charge.(d) Pumping shall be continued till the main pumps installed in sewage sump is cleared for carrying out repair work.(e) rates are deemed to main holes blocking/diverting as desired. (f) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative.(g) Necessary man power to operate the pump set are deemed to be included in the rate. (h) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set.(j) Rate quoted is deemed to included for transportation of pump set from site to authorised work shop and back.(k) Contractor should be provide all safety equipments ie life jocket, oxigen cylinder with breathing apparatus shouit, helmet, shoe, hand glouse, safety belt etc and aplicable of all safety features during this job without any extra cost of Govt.(l) new submersible cable and SWR rope shall be measured and paid separately under relevant item of BOQ.(m) Maint/break down work should be rectify at the earliest otherwise delay may be penalised @ Rs:1000/- per/Hour.
Material and Labour for repairing and servicing /cleaning complete of non clog sewage submersible pump set of the capacity 225 cum/hr, head 20 meter, speed 1450 RPM Model No KRTK 150-315/234 UG1-S make KSB with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories such as nut, bolts, washers etc. Installation with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-charge. Note:- All spare parts as required for repair/overhauling shall be measured and paid separately under relevant item of BOQ and the spares should be suitable to as per above refered model No & make of KSB.
(i) M & L Cutting and taking out existing burnt out/unserviceable copper winding from the stator unit of non clog sewage submersible pump set Cleaning of slots and complete stator unit with using carbon tetra chloride (CTC Solution)/standers cleaner Material and labour for rewinding the motor with 'F' class super enamelled copper wire of existing size/gauge including providing bi-metallic thermal overload protection and all necessary insulating materials such as varnish, insulating paper, sleev etc for 28 HP motor. Note : - Labour for replacement/ fixing the following items i.e. 2.02 to 2.09 is deemed to be included in the quoted rate of item No. 2.01
(ii) Supply only bearing to above make motor & pump
(iii) Supply only Oil seal
(iv) Supply only Impeller stainless steel
(v) Supply only Bearing sleeve
(vi)Supply only Hexagon head bolt
(vii) Supply only Cable duct
(viii) Supply only Screw and Head bolt
(ix) Cooling Oil for Motor (ISO VG 68)
Lifting/ lowering of non clog sewage submersible pump set of the capacity 3,5.5,7.5, 10 & 12.5 HP from the sewage pump houses Lifting : Disconnection of outgoing delivery mains and eletrical connection from the panel and lifting of unserviceable non clog sewage submersible pump set of any depth alongwith column pipe, SWR rope including existing submersible cable and check the unserviceability,remove the sludge/ poly bags/ cement bags/any solid items from inside the pump bowel/impellor and make good working condition with all safetyes etc complete all as directed. Lowering :- Lowering the non clog sewage submersible pump after making operational condition alongwith column pipe, SWR rope including existing submersible cable and all respective items here-in- above lifting and installation of pump motor in its original position, connections the as well as delivery main including electrical connectiion of both end i.e. with starter and motor terminals. Note :- (a) Rate quoted against items deemed to be included for lifting /lowering. (b) lifting equipments like crane/Chain pulley block/fork lift etc will be used according to the load of pump alongwith column pipe and connected items. (c) Any damages to equipment due to negligence of contractor employees during lifting/lowering to be born by contractor at this own risk & cost as per direction of Engr-in- Charge.(d) Pumping shall be continued till the main pumps installed in sewage sump is cleared for carrying out repair work.(e) rates are deemed to main holes blocking/diverting as desired. (f) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative.(g) Necessary man power to operate the pump set are deemed to be included in the rate. (h) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set.(j) Rate are included for transportation of pump set from site to authorised work shop and back.(k) Contractor should be provide all safety equipments ie life jocket, oxigen cylinder with breathing apparatus shouit, helmet, shoe, hand glouse, safety belt etc and aplicable of all safety features during this job without any extra cost of Govt.(l) new submersible cable and SWR rope shall be measured and paid separately under relevant item of BOQ (m) Maint/break down work should be rectify at the earliest otherwise delay may be penalised Rs: 1000/- per/hour.
Material and Labour for repairing and servicing /cleaning complete of non clog sewage submersible pump set of the capacity 3.0,7.5 ,10.0 &12.5 HP make KSB with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories such as nut, bolts, washers etc. Installation with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-charge. Note:- All spare parts as required for repair/overhauling shall be measured and paid separately under relevant item of BOQ and the spares should be suitable to as per above refered model No & make of KSB labour for replacement of items mentioned at ser No 4.05 to 4.11 is included in this item i.e item No 4.00.
M & L cutting and taking out existing burnt out/unserviceable copper winding from the stator unit of non clog sewage submersible pump set Cleaning of slots and complete stator unit with using carbon tetra chloride (CTC Solution). Material and labour for rewinding the motor with 'F' class super enamelled copper wire of existing size/gauge including providing bi-metallic thermal overload protection and all necessary insulating materials such as varnish, insulating paper, sleeve etc for the following capacity of 7.5 HP motor. Note for ser. item No 4.01, 4.02,4.03 : - Labour for replacement of items mentioned at ser. item No. 4.05 to 4.11 as applicable for respective items as mentioned in note is included in the items 4.01, 4.02,4.03 respectively
All as per item No. 4.01 but capacity of 10 HP Motor -ditto-
All as per item No. 4.01 but capacity of 12.5 HP Motor -ditto-
Supply only Bearing suitable to above make pump & motor
Supply only Oil seal
Supply only Impeller stainless steel
Supply only Impeller wear ring
Supply only Bearing sleeve
Supply only Cable duct
Cooling oil for Motor (ISO VG 68)
Taking out old unserviceable centrifugal pump and motor of any make any type from the chamber at sewage pump house and Material and labour for replacement of suitable impeller, bearings and rewinding comprising disconnection/ isolation of electric motor and transporting from site to repair work shop, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with super enamelled copper winding wire of appropriate gauge including all necessary insulation material class-I, varnishing and heating as per requirment. Re-installing in position and reassembling the same after complete repair with accessories such as nut, bolts, washers etc. Installation with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-charge for the following capacity of (a) 2/3 HP electric motors 440 V 3 phase.
All as per item No 5.00 but 5/7.5/10.0 HP Motor -ditto-
Taking out Air cooled twin lobe type UR-1150H V- belt driven air compressors complete with electric motor of capacity 60 HP from the foundation, opening of suction filter , suction silencer, V-pulley for machine, V-pulley for electric motor, V- belts, V- belts guard, safety valve (spring loaded type), NRV and pressure gauge etc and taking aside for carrying out servicing to the blowers, pump with motor by shifting the same to authorised repair workshop of pump make USHA and motor make : ABB. Draining out old used compressor oil cleaning of oil sump properly and replacement of the following items complete all as directed by Engineer Incharge :- (i) suction filter (ii) suction silencer (iii) Pulley for machine (iv) V- belts guard (v) Safety valve (spring loaded type) (vi) NRV (vii) pressure gauge (viii)Compressor oil No 320-06 Ltr.(ix) Set of V-belt ser No SPC-3350-04 Nos each. (x) Replacement of bearings as per existing type and size. (xi) Star plate -01 No.(xii ) Cleaning of pressure line to FAB 1 to FAB4 and Clarifier settling tank replacement of nozzles to ensure proper pressure test in the FABS.(xiii) Carrying out noise level test max allowable as per BI. (xiv) Painting of blower as per existing colour with smoke grey, red and blue where ever marked all as directed.
All as per item No. 6 here in before but capacity of electric motor 7.5 HP -ditto-
Taking out old unserviceable compressor motor of any make any type from sewage pump house and Material and labour for replacement of suitable bearings and rewinding comprising disconnection/ isolation of electric motor and transporting from site to repair work shop, dismantling, stripping out and removing old burnt winding wire, cleaning of slots etc. Rewinding complete with super enamelled copper winding wire of appropriate gauge including all necessary insulation material class-I, varnishing and heating as per requirment. Re-installing in position and reassembling the same after complete repair with accessories such as nut, bolts, washers etc. Installation with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-charge for the following capacity of (a) 60 HP electric motors 440 V 3 phase.
All as per item No 8 but 7.5 HP Motor 440 V 3 phase -ditto-
M & L for taking up raising/ delivery CI/DI/MS/GI water mains (including all fittings), with flanged or spigot and socket ends and lead / flanged joints and nut bolts of any size all as specified and dirercted by Engr-in-Charge of following sizes :-. ( a) 100 mm bore.
( b) 150 mm bore.
(c) 200 mm bore.
Supply and lay DI pipe centrifugally cast of class K-7 with flanged ends including rubber gasket nut bolts for the following sizes. (a) 250 mm bore
(b) 200 mm bore
Material and labour for fixing DI specials such as bends(any type, radius and angle),tappers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps & plugs of size 150 mm bore upto 300mm bore .
Taking out old and Supply and fixing, welding (whereever required, made to shape in existing position vertical), connecting flanged end in length of 3 mtr/6 mtr, MS pipe heavy duty testing after connecting by inserting of new tees, branches etc all as directed of following sizes :- Note:- (Tee, joints shall be inclusive in the cost ). (a) 150 mm bore.
(b ) 100 mm bore.
Taking out old leakage/unserviceable butterfly valves of size 40mm, 50mm, 80 mm, 100mm, 150mm ,200mm and 250 mm from various location in Sewage Treatment plant, Sewage pump houses complete all as directed by EIC.
Supply and fix butterfly valve with standard case flanged type confirming to IS-13095 complete for the following sizes: (a) 50 mm dia
(b) butterfly valve size 80 mm.
(c) Butterfly valve size 100mm.
(d) Butterfly valve size 150 mm
(e) Butterfly valve size 200mm
(f) Butterfly valve size 250mm
Dismantling of unserviceable valves from different locations at sewage plant and Supply, installation, connecting and testing sluice valve 100 mm dia, cast iron body (Long Body) Class PN-1.6 with flanged ends drilled suitable for the following bore of pipes, ISI marked (IS : 14846 : 2000), having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket, etc all as specified and directed.
(a) All as per above item No.15 but size150 mm dia
(b) All as per above item No.15 but size250 mm dia
(c ) All as per above item No.15 but size 300 mm dia
Taking out unserviceable non return valves from the pumping/distribution of raw/treated water line and removing from the site. Supply, fixing and testing Non return valve/reflux valve of 15 Kg/Cm2 body pressure and 10 kg/cm2 seat pressure suitable for 100 mm dia flanged type all as directed.
(a) All as per above item No.16 but 150 mm dia.
(b) All as per above item No.16 but 250 mm dia.
M & L for taking down old unserviceable of LT UG cable of any size and supply, laying, fixing and testing XLPE cable insulated screened PVC bedded copper conductor , galvanised iron strip or wire armoured underground cable of size (a) 10 Sqmm 4 core.
(b) All as per above item No.17 but 16 sqmm 4 core
(c ) All as per above item No.17 but 35 sqmm 4 core
(d) All as per above item No.17 but 50 sqmm 4 core
M & L for taking down existing old unserviceable cable of any size and Supply laying flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable,1100 volts grade 10 Sqmm 3 core including jointing material and connection work. Make : Polycab/Finolex/Havells.
(b) All as per above item No.18 but 6 Sqmm 3 core Make : Polycab/Finolex/Havells.
(c ) All as per above item No.18 but 4 Sqmm 3 core Make : Polycab/Finolex/Havells.
S & F round strand steel wire rope RHO/LHO/RHL/LHL conforming to IS: 2266/02 dia 18/20 mm 1770 N/mm² tensile and connected clamp nut bolts fixed complete all as per directed.Make: BWR/SINTEX/RICHO
M & L for taking down old unserviceable MCCB of rating 32 Amp to 200 Amps,415 Volt. ,3 & 4 pole,415Volt, 25 KA including alluminium cable lugs from existing LT panel of any size and all complete all as directed by EIC. Make :- L & T/SCHNEIDER/LEGRAND/C & S ELECTRIC
Supply and fixing for MCCB, 4 pole,415Volt, 25 KA including cable lugs of suitable size Make: L &T/ Schneider/Legrand,/ C & S electric/Havells complete testing, commissioning complete to the entire satisfaction of Engr-in-charge, the following capacity of (a) 32 Amps.
(b) 40 Amps
(c ) 63 Amps
(d ) 100 Amps
(e ) 125 Amps
(f ) 160 Amps
(g ) 200 Amps
M & L for taking down old unserviceable power contactor of rating MCX 32Amps to 95 Amps,415 Volt. , 4 pole,415Volt, including copper/alluminium cable, lugs of any size complete all as directed by EIC.
Supply and fixing for Power contactor of ,415 Volt. , 4 pole, Make:ABB/Legrand/Havells, including copper control cable for internal wiring with pintype/u type/ring type lugs of suitable size,including operating relays to match the operational function of the contactor of the same all as directed and testing on completion of the work complete all as directed by EIC, the following capacity of Power contactor: (a) 32 Amp up to 40 Amps
(b ) 40 Amp up to 120 Amps
Taking out old unserviceable relays from the existing LT Panel and removing from the site. Supply and fix relay model and make VMR -3P(Relay) Model No PR-07
Taking out old unserviceable pressure gauges with syphon from the pumping/distribution line at various location of sewage treatment plant. Supply and fixing pressure gauge mechanical type of 0 to 100, 0-4 Kg/Cm2 size Make : Hariom, JACOB, H-Guru.
Taking out rusted steel sections from the FAB / Clarifier tube settler tanks by removing dual media filters , cutting the existing corroded, weaken portion from the existing welded structure and removing from the site incuding. Supply, fabrication and connecting cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of water proofing paint coat to the steel surface complete all as directed.
M&L galvanised iron pipe 50mm bore medium grade with and including medium grade (ISI marked) fitting concealed or fixed to walls, ceiling or laid in floors including chase cuttings , making good to disturbed surfaces,complete all as directed and specified with all fittings including taking down old unserviceable pipes..
All as per item No-27 above but size 20 mm bore -ditto-
Taking out existing unservicable LED street light fittings of any shape, size,capacity & position and removing from the site. Material & Labour for replacement/repair of unserviceble items/fittings ie LED individual optical lens, electronic driver etc and controling cable for on/off from light to switch point, suitable existing LED street lights 230 V, 50 Hz. After repair testing,comissioning and same will be fixing in old position complete all as directed by EIC.
Taking out old unserviceable security/street light fittings of any shape and size and removing from the site . Supply and fixing LED street light fitting, 45 Watts, 230 V, 50 HZ, suitable for operation over voltage range of 140 V to 270 V, duly housed in pressure die cast aluminium housing, compressing of LED with individual optical lens, electronic driver with THD <10%, efficiency >85% and PF more than 0.90, confirming to IP65, rendering color index of 75 with cool day light output. MAKE :- Philips/Wipro/C & S electric
Taking out old submersible cable of any shape from the sewage pump to the LT panels and removing from the site. Supply and fixing submersible cable PVC insulated and PVC sheathed multistranded flat copper conductor 7 core 4.0 Sqmm. Make : Havells, Finolex, Paragon, Polycab.
Taking out old submersible cable of any shape from the sewage pump to the LT panels and removing from the site. Supply and fixing submersible cable PVC insulated and PVC sheathed multistranded flat copper conductor 7 core 6.0 Sqmm. Make : Havells, Finolex, Paragon, Polycab.
Dewatering and taking out inside sludge stainers sweeping and taking out sludge in consolidated position from calorifoculater sumps upto depth exceeding 15 mtr including cleaning of internal wall surface and floor throughly to made it free from dirt by scrubbing and washing accumulated materials with water, including cleaning of floculator and sewage raw water chanels, suction discharge lines. After cleaning the following repair works (i) repair/ replacement/welding of damaged scrapper unit and water flow chanels with connected item works. (ii) repair/ replacement of damaged centre flow drum with connected item . (iii) repair of bridge rail leveling, gear box service , oil changing, replace of bearings and V belt as per site required and electric cable connection & functioning. (iv) Painting two coat synthetic enamel painting of complete iron items (v) replace & fixing of new tube settler media (vi) after complete of job testing and commissioning should be done to satisfaction of EIC. Note : (a) the contractor should be responsibulity of all safety features during the work ie hand gloves, mask, belt with rope etc and the Job should be done with in sepervision of contractor/ superviser of the contractor. (b) Any kind of risk during this job Govt/ Depratment should not be held responsible. (c ) Iron & tube settler media is not deemed in the cost and to be measured seperately in relevent of BOQ item.
Dewatering and taking out inside sludge stainers sweeping and taking out sludge in consolidated position from sludge thickner sump upto depth not exceeding 15 mtr including cleaning of internal wall surface and floor throughly to made it free from dirt by scrubbing and washing accumulated materials with water, including cleaning of floculator and sewage raw water chanels, suction discharge lines. After cleaning the following repair works should be done (i) repair/ replacement/welding of damaged scrapper unit and water flow chanels with connected item works. (ii) repair/ replacement of damaged centre flow drum with connected item . (iii) repair of bridge rail leveling, gear box service , oil changing, replace of bearings and V belt as per site required and electric cable connection & functioning. (iv) Panting two coat synthetic painting of complete iron items (v) replace & fixing of new tube settler media (vi) after complete of job testing and commissioning should be done to satisfaction of EIC. Note : (a) the contractor should be responsible for all safety features during the work ie hand gloves, mask, belt with rope etc and the Job should be done with in sepervision of contractor/ superviser of the contractor. (b) Any kind of risk during this job Govt/ Deptt. should not be held responsible. (c ) Iron & tube settler media is not deemed in the cost and is measured seperately in relevent BOQ item..
Dewatering ,sweeping and taking out sludge in consolidated position from under ground sumps upto depth not exceeding 15 mtr including cleaning of internal wall surface and floor throughly to made it free from dirt by scrubbing and washing accumulated materials with water, including cleaning of suction lines inside wet sump and removing from site etc complete all as directed at site. Note : (a) the contractor should be responsibulity of all safety features during the work ie hand gloves, mask, belt with rope etc and the Job should be done with in sepervision of contractor/ superviser of the contractor. (b) Any kind of risk during this job Govt/Deptt. should not be held responsible.
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed of following sizes incl taking down old unserviceable and removal from site:- (a) 15 mm dia
(b) 20 mm dia
(c ) 25 mm dia.
Supply and fix in replacement of timer for motor starter 0-30 sec./3-30 Sec making all incoming and outgoing electric connection complete all as directed by Engr-in-Charge. Make : Cat No-800 SD Make : Selec or equivalent in BCH /L & T/ ABB / LEGRAND/HAVELLS
Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground eath (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanized iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvnised iron or steel all as specified & shown in electrical plate No.5 of MES SSR part-I connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe & watering pipe shall be 20 mm bore medium grade including excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including charcoal , salt funnel GI pipe 40 mm dia light grade up to to 7.5 mtr length ,all as directed at site.
Material and labour for Earthing strip , galvanised iron strip 30 x 6 mm , burried in ground or fixed to pole/ wall with saddles etc all as specified and directed by Engr-in-Charge. Earth work if required shall be measured and paid against respective item of BOQ.
Taking out u/s tube light fittings at various sewage installations and S & F wall/ceiling mounting luminaries LED tube light fitting 1x 28 W 230V Energy effecient T5 box type epoxy powder coated CRCA sheet with electronic ballast bi-pin holder internally prewired complete with all accessories and 1 x 28 watt LED tube light (Make :wipro/ Surya/Havells/Syska/Phillips)
Dismantling of stone massonary valve chamber of any size and pattern and at any position and construction of valve chamber with PCC foundation 1:4:8 type D2 using 40mm graded stone aggregate R. R stone massonary built in cement mortar 1:6, plastering with cement mortar 1:4, 15mm thickness internally and externally above and below ground level with PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping, including frame made of angles iron of size 40x40x5mm matches with the internal size of the valve chamber and chamber cover made of 3mm thick MS Sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer to steel surface incl necessary earth work, excavation etc all as specified and directed by Engr-in-Charge for size 900mm x 800mm x 1200mm.
Taking out Unserviceable chlorine/ polyelectrolite dozing machines from STP at any position & any make and transport to authorised civil workshop, dismantling, take out unserviceable items and refixing new items as suitable for existing make and refixing the same at original position and testing & commissioning after repair complete all as directed by EIC.
M & L for Excavation in trenches not exc 1.5m width and n. exc 1.5m in depth and getting out for laying of pipes etc in any type of soil.
M & L for Returning filling in incl spreading levelling watering and well ramming in layers n.exc 25cm in any type of soil.
M & L for Removing excavated material n.exc 50m and depositing where directed at a level n. exc 1.5m above starting point.
M&L PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation of pillar complete all as directed.
M&L PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in coping on brick masonry or pillar and like complete all as directed by EIC.
M&L brick work in cement mortor (1:6) as in brick pillar for testing of CI pipe line complete all as directed.
M&L 15 mm thick cement plaster in cement mortor (1:6) on brick surface fair and even complete all as directed
M&L for sand cushioning with layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable, in trenches complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection all as directed by Engr-in-Charge.
M & L for surface dressing including uprooting bushes/ grass etc all as directed by Engineer Incharge.
Taking out unservieable/ burning out soft starter to authorised work shop and material and Labour for repairing and servicing /cleaning of Soft starter as per existing capacity/model/make at 9.5 MLD STP with replacement of worn out /unserviceable parts and reassembling the same after complete repair with suitable accessories. Installation with proper alignment including testing, commissioning complete to the entire satisfaction of Engr-in-charge. Note:- (a) the cost of all spare parts & repair/overhauling is deemed in this item rete. (b) the spares should be suitable to as per existing model & make. (c) Contractor will provide alternate starter for functioning of motor/pump till starter is repaired & re- installed, the rates deemed to be included in quoted rates.
Supply and laying PVC pipe for cable protction size of 40 mm outer dia with all fittings and fixtures required complete all as directed by Engr-in- charge.
Disconnecting and taking down old unserviveable star-delta starter from existing panel and removal from the site complete all as directed by Engr- In Charge.
Supply, Installation and commissioning of digital soft starter suitable for 60/50 HP(44/37 KW) having motor protection with built in by pass on PSTB,inside delta connection, Coated PCBs, Display and keypad, Torque control/ Pump control,Settable current limit function, Electronic motor overload protection, locked rotor protection, Thyristor over temprature protection, Under load protection and Anlog out put complete and suitable to fix in existing panel with external Contactor,MCCB 4 Pole, safety fusing system of suitable rating to take load of pump motor,including MCB SP of rating 6 Amps, 240 Volt , "C" curve and suitable control transformer including panel internal wiring as per requirement complete all as directed by Engr- In-Charge at site.Make: ABB /Siemens/ L & T. Complete all as directed by Engr-in-charge.
Lifting/ lowering of submersible pump set of the capacity 55 LPS, head 45 mtr make KSB from the UG sump/open well of depth 30 feet . Lifting : Disconnection of outgoing delivery mains and eletrical connection from the panel and lifting of unserviceable sewage submersible pump set of any depth alongwith column pipe, SWR rope including existing submersible cable and check the unserviceability,remove the sludge/any solid items from inside the pump bowel/impellor and make good working condition with all safetyes etc complete all as directed. Lowering :- Lowering the submersible pump after making operational condition alongwith column pipe, SWR rope including existing submersible cable and all respective items here-in- above lifting and installation of pump motor in its original position, connections the as well as delivery main including electrical connectiion of both end i.e. with starter and motor terminals. Note :- (a) Rate quoted against items deemed to be included for lifting /lowering.
Material and Labour for repairing and servicing /cleaning complete of submersible pump set of the capacity 55 LPS, head 45 meter, speed 1450 RPM,Make KSB with replacement of worn out /unserviceable parts and reassembling the same after complete repair with accessories such as nut, bolts, washers etc. Installation with proper alignment including testing, commissioning and painting with two coats of synthetic enamel paint complete to the entire satisfaction of Engr-in-charge. Note:- All spare parts as required for repair/overhauling shall be measured and paid separately under relevant item of BOQ and the spares should be suitable to as per above refered model & make of KSB.
Cutting and taking out existing burnt out/unserviceable copper winding from the stator unit of submersible pump set Cleaning of slots and complete stator unit with using carbon tetra chloride (CTC Solution). Material and labour for rewinding the motor with 'F' class super enamelled copper wire of existing size/gauge including providing bi-metallic thermal overload protection and all necessary insulating materials such as varnish, insulating paper, sleev etc for 50 HP motor including replacement of unservicable spares like suction cover, half coupling pump SS shaft , neck ring, SS sleeves, SHAFT key, bowl bush, discharge outlet, impelleer, NRV, Pump bowel etc as required for installation and testing complete all as directed by Engineer Incharge.
Lifting/ lowering aerators with horizontal submersible pump set of the capacity 10/12.5 HP from the Eco lake Lifting : Disconnection of eletrical connection from the panel and lifting of unserviceable aeraor with centrifugal submersible pump set of any depth alongwith, nylon rope, including existing submersible cable and check the unserviceability,remove the sludge/ poly bags/ any solid items from inside the pump bowel/impellor and make good working condition with all safetyes etc complete all as directed. Lowering :- Lowering the aerator with centrifugal submersible pump after making operational condition alongwith nylon rope including existing submersible cable and all respective items here-in- above lifting and installation of aerator in its original position, connections the as well as delivery main including electrical connectiion of both end i.e. with starter and motor terminals. Note :- (a) Rate quoted against items deemed to be included for lifting /lowering. (b) Bouat/Hydra plant will be used for liftin/lowering according to the load of aerator alongwith connected items. (c) Any damages to equipment due to negligence of contract during lifting/lowering to be born by contractor at this own risk & cost as per direction of Engr-in- Charge.(e) Necessary man power to lifting/lowering are deemed to be included in the rate. (f) Rate quoted is deemed to including testing of aerator.(g) Rate included for transportation of pump set from site to authorised work shop and back.(k) Contractor should be provide all safety equipments ie life jocket, oxigen shouit, helmet, shoe, hand glouse, safety belt etc and aplicable of all safety features during this job without any extra cost of Govt.
M & L for repair/replacement/maintenance of sluice valves of size from 100mm dia upto 300 mm dia, complete all way keep in no leakage condition including i.e. excavation,removal and refilling of trenches). Pumpimg out water from the ditch and rectify the deffects by taking out of existing spares ie rubber gasket / fibre sheet, nut & bolt etc and rejoining the same by using new one incl testing, commissioning of valve complete all as directed at site and complete all as directed by Engr-in-charge. Note:- All spare parts shall be measured and paid separately under relevant item of BOQ and the spares should be suitable to as per above refered model/make .and record shall be maintained in register & put up fortnightly to Engr-in-charge labour for replacement of the items mentioned at ser 61.01 to 61.07 deemed to be included in the rates quoted of item no 61.
(i) Gland Cup
(ii) Rubber Gasket
(iii) Spindle brass
(iv) Lock nut
(v) Brass rings
(vi) Butterfly valve flap with rubber gasket inner and outer set.
(vii) Nut bolts & wahsers of different sizes.
Cutting and taking out existing bunt out/unserviceable copper winding from the stator unit of centrifugal submersible pump set of capacity 10/12.5 HP motor, cleaning of slots and complete stator unit with using carbon tera chloride (CTC solution). M & L for rewinding the motor with 'F' class super enameled copper wire of existing size/gauge including providing bi-metallic thermal overload protection and all necessary insulating materials such as varnish, insulating paper, sleeve etc including repalacement of U/S parts,i.e O rings, oil seal, impeller, bearing seal, mechanical seal, radial/ball bearing etc including testing and commissioning complete all as directed by Engineer incharge.
Shri Ram Traders Co
vijay enterprises
Shri Electrical Enterprises
Siddharth Constructions
M/s Vishaka Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .