Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC M/S Krishna Construction Company is the Lowest Bidder, hence accepted | |
| 2 | L2₹10.8 L+₹66,800 (6.61%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹12.0 L+₹1.8 L (18.2%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹13.8 L+₹3.7 L (36.2%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
4 Jul 2024, 6:00 pmClosed
Sh Nitish Pathak, EE
GE (AF) Phalodi
REPAIRS/REPLACEMENT AND CLEANING OF WATER TANKS AND CONNECTED ACCESSORIES IN DOMESTIC AREA AT AF STN PHALODI
2024_MES_657951_1
8563/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Station Phalodi
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹30,000
Yes
31 Aug 2024
5 Jun 2024
11 Jul 2024
5 Jun 2024
4 Jul 2024
21 Jun 2024
Amount
Dismantling of water tank exc 250 litres & n. exc 500 litres capacity complete all as specified and directed.
Dismantling of water tank exc 500 litres & n. exc 1000 litres capacity complete all as specified and directed.
Dismantling of water tank exc 1000 litres & n. exc 2000 litres capacity complete all as specified and directed.
M&L for cleaning and removing all scale and dirt , etc from tank of capacity exc 250 & n. exc 500 any type including cleaning using bleanching powder or any other tank cleaning agent and mouths of circulating pipes etc complete all as specified and directed.
M&L for cleaning and removing all scale and dirt , etc from tank of capacity exc 500 & n. exc 1000 any type including cleaning using bleanching powder or any other tank cleaning agent and mouths of circulating pipes etc complete all as specified and directed.
M&L for cleaning and removing all scale and dirt , etc from tank of capacity exc 1000 & n. exc 2000 any type including cleaning using bleanching powder or any other tank cleaning agent and mouths of circulating pipes etc complete all as specified and directed.
Disconnecting existing exc 250 litres & n. exc 500 litres capacity water tanks, setting aside (or lowering , if required) for repairs, cleaning , etc and hoisting if required reconnecting and refixing in position , complete all as specified and directed.
Disconnecting existing exc 500 liters & n. exc 1000 litres capacity water tanks, setting aside (or lowering , if required) for repairs, cleaning , etc and hoisting if required reconnecting and refixing in position , complete all as specified and directed.
S&F rotational moulded polythylene 500 litres capacity liters water storage tanks tripple layer (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR Part -I complete all as specified and directed.
S&F rotational moulded polythylene 750 capacity liters water storage tanks tripple layer (cylindrical verical with closed top ) hoisted and fixed in position all as specified in SSR Part -I complete all as specified and directed.
S&F rotational moulded polythylene 1000 capacity liters water storage tanks tripple layer (cylindrical verical with closed top ) hoisted and fixed in position all as specified in SSR Part -I complete all as specified and directed.
S&F rotational moulded polythylene 2000 capacity liters water storage tanks tripple layer (cylindrical verical with closed top ) hoisted and fixed in position all as specified in SSR Part -I complete all as specified and directed.
S&F 25 mm bore brass ball valves high pressure with polythene float any flynut complete , screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 25 mm bore brass ball valves high pressure with polythene float any flynut complete , screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F 20 mm bore brass ball valves high pressure with polythene float any flynut complete , screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 20 mm bore brass ball valves high pressure with polythene float any flynut complete , screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store , complete all as specified and directed.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed.
S&F 15 mm bore Galvanized Steel tubes, medium grade with all fittings ,fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm bore Galvanized Steel tubes, medium grade with all fittings fixed to walls and ceilings or laid in floors, complete all as specified and directed.
S&F 25 mm bore Galvanized Steel tubes, medium grade with all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and directed.
Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.) including cleaning 15 mm nominal bore complete all as specified and directed.
Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.) including cleaning 20 mm nominal bore complete all as specified and directed.
Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.) including cleaning 25 mm nominal bore complete all as specified and directed.
S&F in repair PVC water tank cover with fittings , suitable for tanks of capacity for tank 500 ltr to 1000 liter including hinging device complete all as specified and directed.
S&F in repairs 20 mm bore dia Gun-metal, globe or gate valves cast copper , with iron whees head , screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repairs 25 mm bore dia Gun-metal, globe or gate valves cast copper , with iron whees head , screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repairs 25 mm bore dia of pipe PTMT nipple suitable for HDPE water tank .(Minimum Wt 65 gms) complete all as specified and directed.
S&F in repairs 20 mm bore dia of pipe PTMT nipple suitable for HDPE water tank .(Minimum Wt 45 gms) complete all as specified and directed.
M&L for cleaning of non accessible roof surfaces by brooming , scraping and picking off the dust and dirt, removing leaves, removing plant roots including ensuring drainage system is free flowing and making good disturbed surfaces with cement mortar (1:3) complete all as specified and directed. Note: (i) Cost of necessary tools, saftey belts and ladders etc shall be deemed to be included in the unit rate quoted. (ii) Removing of all debris shall be disposed outside MOD land
Aggarwal brothers and company
M/S Balkishan Panwar Construction
M/S VISHNOI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .