Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.6 CrAccepted-AOC SAHNEWAL DEHLON ROAD VILL PADDI LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | ₹18.6 Cr | L-1 | Accepted-AOC Lowest |
| 2 | L-2₹19.0 CrRejected-AOC 208 L MODEL TOWN LUDHIANA | LUDHIANA | PUNJAB | 141001 | ₹19.0 Cr | L-2 | Rejected-AOC Highest |
| 3 | L-3₹19.2 CrRejected-AOC 472 D MODEL TOWN EXTENSION LUDHIANA | ₹19.2 Cr | L-3 | Rejected-AOC Highest |
| 4 | L-4₹20.3 CrRejected-AOC | ₹20.3 Cr | L-4 | Rejected-AOC Highest |
| 5 | L-5₹21.8 CrRejected-AOC 140 H SBS NAGAR LUDHIANA | LUDHIANA | ₹21.8 Cr | L-5 | Rejected-AOC Highest |
Updated dates
Tender Value
₹23.7 Cr
EMD Value
₹47.4 L
Closing Date
30 Dec 2025, 12:00 pmClosed
Executive Engineer Provincial Division PWD LDH
Executive Engineer Provincial Division PWD LDH
Upgradation of Plan Road Kohara Machhiwara, Bhaini Sahib, Ramgarh, GGS Marg, Gounsgarh Road under Head Special Assistance 5054 RB 10 Scheme including Maintenance of Road for 5 Year One year Defects Liability Period plus Four Year L 31.50 KM
2025_CEPW_154317_1
Bid No.44 dated 21.11.2025 (D)
Open Tender
Civil Works - Roads
270 days
Ludhiana
Please refer Tender documents.
23 documents required · 23 mandatory
₹50,000
₹47.4 L
Executive Engineer Provincial Division PWD LDH
13 Mar 2026
24 Nov 2025
30 Dec 2025
24 Nov 2025
30 Dec 2025
24 Nov 2025
5 Dec 2025
Dismantling of flexible pavements thickness above 50mm by mechanical means an
d disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications
Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications.
Dismantaling of brick work /tile masonary or tile lining. (i) Dismantaling of dry brick work
(-) D/d Credit of old useful serviceable materials like Brick Bats & Bricks which obtained from Dismantling of existing brick edging
(i) Brick Bat
(ii) Bricks
Scarifying the existing Bituminous road surface to a depth of 50mm and disposal of scarified material with in all lifts and lead upto 1000 meters
Relaying of recovered material obtained from dismantling of road crust as construction of granular sub-base by providing coarse graded matereal grading-II spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achive the desired density, complete as per technical clause 401 of MORT&H specifications.
Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications
Providing and laying of Brick on end edging 6.83cm wide, 11.11cm long and 22.86cm high half brick deep including excavation, refilling and disposal of surplus earth up to 50mtr complete as per Punjab PWD specifications
Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications
Providing, laying, spreading and compacting stone aggregates of Grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications
Providing and applying tack coat with penetration grade bitumen VG- 10 using bitumen pressure distributor @ of 0.40 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications
Providing and laying patch work with bituminous macadam 50mm to 75mm thick using crushed stone aggregates of specified grading premixed with bituminous binder VG-30 @ 3.4% in Continuous type hot mix plant, carriage of mixed material to site of work, laid after trimming the pot hole, removal of failed material, laying by suitable means and rolling with a smooth wheeled roller to match the adjoining surface complete as per technical clause 504 of MORT&H specifications
NOTES : - I. The actual volume of the aggregate to be paid for shall be computed after deducting the specified percentage from the volume computed by stacks measurement as per MORT & H specifications (addendum to latest revision) for the purpose of secured advance." II. The final grading for the aggregates required for bitumenious macadam course Grading 2 for 75 mm / 50 mm thickness of each layer conforming to table 500-7 of M.O.R.T. & H specifications (addendum to latest rivision) shall be determined after getting the bitumenious macadam grading-2 designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60 % of material. The design mix so finally approved by shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set fourth in table 500-6 (addendum to latest revision). III. The mix shall exhibit the following details: a) Binder expressed as a percentage by weight of total mix. b) Coarse aggregate of 26.5 mm gauge expressed as percentage by weight of total mix. c) Crushed Bajri of 11.2 mm size expressed as percentage by weight of total mix. d) Fine aggregates 4.75 mm below expressed as percentage by weight of total mix. e) A single definite percentage passing each sieve for mixed aggregates. f) Density of Bitumensious macadam (75 mm/ 50mm thick after compaction) shall be minimum 2.2 gms/C.C & nothing extra shall be payable if higher density is achieved at site. IV) The Contractor thereafter, shall be required to complete the supply of various ingradients or Bituminous macadam as per proportions stipulated in the approved mix. V) Rate of B.M shall be quoted by the contractor with respect to binder content percentage by weight of mix being 3.4 % if Laboratory designs a mix with different percentage then the difference shall be payable / recoverable.
Providing and laying dense graded bituminous macadam 50-75mm thick with batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications NOTES:- (i) Job mix formula for the dense bituminous macadam shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research Laboratory Patiala before adoption at site for execution. (ii) The specification of this item for analytic purpose is kept with bitumen content @ 4.50% weight of mix variation as compared with job mix formula shall be paid/ deducted accordingly. The limits of variation shall be worked out with the approved formula. TECHNICAL NOTE:- I.) Apart from the conformity with the grading and quantity requirement of individual ingredients exhibited above the mix aggregate i.e. coarse and fine aggregate for dense bituminous concrete shall meet all requirements set forth clause 505 of MORT&H specifications. II.) The final grading for the aggregates required for dense bituminous macadam confirming to table 500.10 of MORT&H specifications shall be determined after getting the dense bituminous macadam designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60% of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set forth in table 500-6 (addendum to latest revision). III.) The approved mix shall exhibit the following details source and location of all material:- (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix. (e) A single definite percentage passing each sieve for mixed aggregates. (f) Density of dense bituminous macadam after compaction will be not less than 2.30 gm/CC
Providing and laying bituminous concrete 30-45mm thick with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.4%, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 507 of MORT&H specifications NOTES:- (i) Job mix formula for the bituminous concrete shall be provided by the agency and shall be got approved from Punjab PWD, B&R Research laboratory Patiala before adoption at site for execution. (ii) The specifications of this item for analytic purpose is kept with bitumen content @ 5.4% weight of mix variation as compared with job mix formula shall be paid/ deducted accordingly. The limits of variations shall be worked out with the approved formula. TECHNICAL NOTE:- i.) Apart from the conformity with the grading and quantity requirement of individual ingredients exhibited above the mix aggregate i.e. coarse and fine aggregate for bituminous concrete shall meet all requirements set forth clause 507 of MORT&H specifications. ii.) The final grading for the aggregates required for bituminous concrete confirming to table 500.17 of MORT&H specifications shall be determined after getting the bituminous concrete designed from Punjab PWD, B&R Research Laboratory Patiala after obtaining 60% of material. The design mix so finally approved shall be termed as the approved mix. The aggregates shall be hydrophobic and of low porosity. The aggregates shall satisfy the physical requirement set forth in table 500-6 (addendum to latest revision). iii.) The approved mix shall exhibit the following details, source and location of all material:- (a) Binder expressed as percentage by weight of total mix. (b) Course expressed as percentage by weight of total mix. (c) Crushed bajri expressed as percentage by weight of total mix. (d) Fine aggregate expressed as percentage by weight of total mix. (e) A single definite percentage passing each sieve for mixed aggregates (f) Density of bituminous concrete after compaction will be not less than 2.35 gm/CC.
Providing and laying surface dressing in single coat using crushed stone aggregates of specified size on a layer of bituminous binder VG-10 @ 1kg per sqm laid on prepared surface after cleaning the road surface and rolling with 8-10 tonne smooth wheeled steel roller complete as per technical clause 509 of MORT&H specifications.
Construction of Shoulder with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement as per Clause 3003 of MORT&H specification.
Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications
Crack Prevention Courses (Stress Absorbing Membrane crack width 6mm to 9mm) Laying of a stress absorbing membrane over a cracked road surface after cleaning the road surface, using modified binder CRMB-55 complying with clause 517 @ 1.1kg per sqm and crushed stone aggregates of specified grading, spraying binder and spreading crushed stone aggregates, sweeping the surface for uniform spread of aggregates complete as per technical clause 517 of MORT&H specifications
Crack Prevention Courses (Stress Absorbing Membrane crack width less than 6mm) Laying of a stress absorbing membrane over a cracked road surface after cleaning the road surface, using modified binder CRMB-55 complying with clause 517 @ 0.90kg per sqm and crushed stone aggregates of specified grading, spraying binder and spreading crushed stone aggregates, sweeping the surface for uniform spread of aggregates complete as per technical clause 517 of MORT&H specifications
Reinforced cement concrete M-15 grade ordinary kilometer stone of standard design as per IRC 8- 1980 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications
Providing and making rumble strips 15-20mm high at centre, 250mm wide placed at 1m centre to centre over freshly laid bituminous layer by using close graded premix surfacing material type B at approved locations to control speed and marked with 100mm wide white strips of thermoplastic road marking paint. The close graded premix surfacing material type B shall conform to technical clause 512 and thermoplastic road marking paint shall conform to technical clause 803 of MORT&H specifications
Reinforced cement concrete M-15 grade boundary pillars of standard design as per IRC 25-1967 fixing in position including painting and printing etc. complete as per technical clause 806 of MORT&H specifications
Reinforced cement concrete M-15 grade village board of standard design fixing in position including painting and printing etc. complete as per PWD specifications
Providing and laying 80 mm thick factory made cement concrete interlocking Paving blocks of M-40 grade machine made rubbder moulded smooth finish with strong vibratory process and approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge.
Construction of side Drain Size 12"x12" complete in all respects
Construction of 1'-6" Hume Pipe Culvert complete in all respects
Reinforced cement concrete M-15 grade 200 meter stone of standard design as per IRC 26- 1967 fixing in position including painting and printing etc. complete as per technical clause 804 of MORT&H specifications
Construction of 2' Span Slab Type Culvert complete in all respects
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminum Composite material (ACM) sheeting having aluminum skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminum alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012
Mandatory sign board 900mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67- 2012 . Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012
Raising of Manhole Cover and Frame including Slab complete in all respects
Advance Direction sign board 1200x900mm rectangular Type IV per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. grade sheeting fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test lab
Heritage & Culture Cess @ 1.00%
Cancer Cess @ 1.00%
Routine Maintenance of construction work as per periodicity to routine maintenance mentioned in the technical specifications. (For 2nd Year)
Routine Maintenance of construction work as per periodicity to routine maintenance mentioned in the technical specifications. (For 3rd Year)
Routine Maintenance of construction work as per periodicity to routine maintenance mentioned in the technical specifications. (For 4th Year)
Routine Maintenance of construction work as per periodicity to routine maintenance mentioned in the technical specifications. (For 5th Year)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 12.03 MB
Tendernotice_2.pdf
PDF • 2.85 MB
Tendernotice_3.pdf
PDF • 1.83 MB
BOQ_312870.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid