Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹20.1 L+₹4.9 L (32.2%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹21.2 L+₹6.0 L (39.2%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) JODHPUR
GE (AF) JODHPUR
CERTAIN MISC BR AND EM REPAIR WORK IN TECH AREA AT AF STN UNDER GE AF JODHPUR
2023_MES_605840_1
8583/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE (AF) JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JODHPUR
₹36,000
Yes
21 Aug 2023
27 Jun 2023
26 Jul 2023
27 Jun 2023
24 Jul 2023
11 Jul 2023
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and disposing off debris properly outside MD land complete all as specified and as directed.
Excavation over areas n.exc 1.5 m deep and getting out in hard / dense soil complete all as specified and directed.
Removing excavated materials/ demolished material of outside MOD Land and depositing/ dumping at a place identified by the contractor at his own cost and arrangement complete all as specified and directed.
M& L for rolling and consolidation of formation surface with 8 to 12 tonnes power roller complete all as specified and directed.
M&L for hardcore of gauge exc. 63mm but n. exc. 100mm deposited spread and levelled in layers n. exc. 15cm thick, watered and rolled and rammed to a true surface with broken stone or boulders as in hardstanding complete all as specified and directed.
M&L for 150mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in sub base complete all as specified and as directed.
M&L for sand filling under floor or below interlocking tiles including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 80mm thickness , M-35 Grade set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sqm and removing from site complete all as specified and as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded completed all as specified and directed.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples completed all as specified and directed.
S&F sheet glass 4 mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane completed all as specified & directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
S&F in repairs 8 mm thick calcium silicate boards of size 600 mm x 600 mm in false ceiling complete all as specified and as directed .
M&L for welding in repairs of metal steel plates/ section /angles thickness exc 9mm but n exc 20mm complete all as specified and directed.
M&L for 150 mm thk cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) for sub base flooring complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth complete all as specifed and directed.
M&L for complete removal of existing treatment from surfaces of Walls, including rubbing the surface with steel wire brush or grinder and finally with fine sand paper and applying one coat of white cement base wall care putty as directed, finish the surface even and smooth with fine sand paper and applying two coats of oil bound distemper over and including a coat of primer, including cleaning of windows, doors, internal fittings & any other surfaces by removing splashes / spots after finishing the job and leaving premises, clean and tidy, complete all as specified and as directed .
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but n. exc 4 sqm each and removing from site complete all as specified and as directed.
S&F rolled mild steel for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, confirming to Fe 290 (Gde E-165) complete all as specified and as directed.
S&F Mild steel, plain, black 1.00 mm thick sheet in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. required complete all as specified & directed.
M&L for preparation of new or previously untreated steel surfaces exc 10 cm in width or girth and applying two coats of fire resistant paint over and including a coat of red oxide primer complete all as specified and as directed.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit rotory compressor 2 Tonne capacity, single phase, 230 volt of including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure testing, leakage, rectification and supply & fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed.
Material & labour for WATER JET servicing of SPLIT TYPE AC's of 1.5/2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil, condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstalling at the same location complete all as specified & directed. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
Supply & fixing in replacement complete Indoor unit with remote of Split AC capacity 2 Ton of existing make complete all as specified & directed.
Supply & fixing in replacement complete outdoor unitof Split AC capacity 2 Ton of existing make complete all as specified & directed.
Material & labour for sub main wiring with two run of 6.0 Sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including metallic steel surface conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all on wall and surface on ceiling and including one run of 6.0 Sqmm FRLS cable multistranded copper conductors 1100 volt grade earth continuity conductor complete including taking down existing sub main wiring all as specified and directed by Engineer in charge. (Note : Two runs of main cable and one run of earth wire including one run of metallic steel surface conduit pipe shall be measured and paid as one unit.)
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply & fixing in repairs condenser coil for split type AC 1.5/2.0 Tonne capacity of any make including charging of gas R-22/R407C complete all as specified & directed.
Supply & fixing in repairs sheet metal enclosure SPN with two pin and earth plug socket with & including 20Amps MCB 'C' curve single pole 240 Volt AC complete all as specified & directed.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 ton and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge.
Material & labour for filling of Refrigerant R-22 complete all as specified & directed.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ⅝" dia of split type AC's any capacity complete all as specified & directed.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size¼" dia of split type AC's any capacity complete all as specified & directed.
Supply & fixing in repairs flexible drain pipe ( PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 50 MFD 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 2.5 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 4 MFD, 230 volts, 50 Hz.suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 6 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan motor of capacity 1.5/2.0Tonne for split type AC's single phase, AC 230 volts, 50 Hz of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs AC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/2.0 Ton Split type AC's complete all as specified & directed by the Engineer-in-Charge.
S&F in repairs MCB 6 to 32 Amps SP ,240 V ,10 KA 'C' curve,IP 20 complete all as specified and directed.
Supply & fixing in repairs MCB SP 40 Amp, ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
S&F in repairs MCB 40 to 63 Amps SPN ,240 V C curve 10 KA,IP 20 complete all as specified and directed.
Material & labour for reparing of PCB control card suitable for 1.5/2.0 Tonne capacity split type AC/window ac, single phase and make the PCB control card functional complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs capillary copper tube (ISI Marked) of split /window type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
S & F in replacement PCB control card suitable for 1.5/2.0 Tonne capacity split type AC/window ac, single phase and make the PCB control card functional complete all as specified & directed by the Engineer-in-Charge.
Disconnecting, taking down flame proof exhaust fan/air circulator of any make any size as existing at site, dismantaling blades etc, opening of fan motor, cleaning of fan body and blades using detergent including striping, cutting the existing copper winding wire of ceiling fan and Material and Labour for rewinding the same with heavy duty super enamelled copper wire /winding of existing gauge size, same No of turns, wound with machine, providing insulation material of E-grading, varnishing with insulation material, and reassembling the fan motor, oiling & greasing the same after repair ,including painting to ceiling fan with Spray painting with super enameled heat resistant synthetic enamel white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape and refixing the ceiling fan with screw, nut bolts washer and locking arrangement, flexible electric copper wire connection complete works etc and testing after repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix single pointed air termination aluminium rod 12mm dia 300mm long in replacement.
S&F in replacement aluminium strip 25x3.15 mm complete with saddles and fixing screw for fitting the strip complete all as specified and as directed.
S&F in replacement copper strip 20mmx3mm complete with,protection sleeves, saddles, seprator and fixing screws at surrounding inside and outside the building complete all as specified and as directed.
S&F in replacement galvanised iron pipe 40mm dia medium grade with all fittings for cable protection laid in trenches or sufaces to wall complete all as specified and directed.
S&F in replacement of seprator U type made of porcelene used for earth strip mounting with all nut bolts and connecting accessories directed.
S&F in replacement test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw as required with accessories complete all as specified and directed
S&F in replacment of kota stone earth pit cover (2x2 feet) including removing old broken stone cover complete all as directed.
Dismantling of old unserviceable PCC earthing chamber, and Material & Labour for construction of PCC chamber made out of PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate and cover shall be 40mm thick RCC Pit cover made of precast cement concrete cover slab type B-1 (PCC 1:2:4) using 20 mm graded crushed stone aggregate , reinforced with mild steel XPM weighing not less than 4 kg/ Sqm, including necessary form work & surfaces of PCC Chamber Shall be finished smooth without using extra cement , Exposed surfaces shall be given three coats of white wash complete, minimum dimention of PCC Chamber shall not be less than as specified & shown on Plate No 3 of SSR Part I (2009) complete all as specified and directed. Note : The rate quoted for this item also includes necessary excavation and earth work, disposal of surplus soil/material to a distance not exc. 50 metres complete.
M&L in replacement for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 20 mm X 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe up to 7.5m complete all as specified and directed by the Engineer-in-Charge NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately.
M & L in replacement for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
Supply only of Potassium Nitrate (commercial name kalmi shora) in the earthing chambers for improvement of the existing earthing resistence complete all as specified and directed.
S&F in replacment of 35 sqmm multistranded flexible copper conductor cable single core fixed on wall sufaces with suitable mounting accessories of non conductive material complete all as specified and directed.
S&F in repairs copper lugs suitable for cables of size 36 sqmm complete all as directed.
S&F in repairs HDPE pipe of 50mm dia complete with all accessories complete all as specified and directed.
M&L for painting of existing steel tubular pole with two coats of aluminium paint after srapping old surface making clean as directed by Engineer in charge.
Savitri Enterprises
M/S SUA DEVI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .