Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Garrison Engineer Utility-II Visakhapatnam
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
SPECIAL REPAIRS TO EXTERNAL WATER SUPPLY SYSTEM AT MEGADRIPETA COLONY UNDER GE (U-II) VISAKHAPATNAM
2026_MES_797062_1
8220(A)
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility-II
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility-II
₹96,000
Yes
3 Nov 2026
3 Nov 2026
25 Nov 2026
3 Nov 2026
24 Nov 2026
18 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, laying, jointing, testing and commissioning of 200mm dia, class K-7, Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete including taking down of old existing CI pipe with fittings of any description, complete all as specified and as directed by Engineer-in-Charge. | 69.6 | RM | 1.25 | ₹87 |
| - | Supplying, laying, jointing, testing and commissioning of 150mm dia, class K-7, Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete including taking down of old existing CI pipe with fittings of any description, complete all as specified and as directed by Engineer-in-Charge. | 667.1 | RM | - | - |
| - | Supplying, laying, jointing, testing and commissioning of 100mm dia, class K-7, Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete including taking down of old existing CI pipe with fittings of any description, complete all as specified and as directed by Engineer-in-Charge. | 297.3 | RM | 100 | ₹29,730 |
| - | Material and Labour for DI fittings (Class K-12) suitable for DI spigot and socketed pipe of size from 100 mm to 200 mm bore and any type such as MJ Collar, Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket/flanged etc), Tee pieces (single branch, "Y" junction, double branch, cross etc), collars, caps and plugs etc, complete all as specified and directed by Engineer-in-Charge. | 500 | KG | 53 | ₹26,500 |
| - | Material and Labour for GI pipe 80 mm dia bore, medium grade with all fittings such as flanged/ Sockets, Reducers, Unions, Tees, Nipples, Bends etc laid in trenches, complete all as specified and directed | 465.7 | RM | 10 | ₹4,657 |
| - | Supply and laying/fixing of 3 layer (inner antimicrobial, outer UV stablised) ISI marked, IS 15801, PP-R pipes SDR 7.4 (PN-16) including PP-R plain/brass fittings in trenches/walls/ceiling or laying in floors complete of size outer dia 25 mm including taking down of old existing GI pipe 20 mm dia and fittings, complete all as specified and directed by Engr-in-Charge | 2,000 | RM | 11 | ₹22,000 |
| - | Supply and laying/fixing of 3 layer (inner antimicrobial, outer UV stablised) ISI marked, IS 15801, PP-R pipes SDR 7.4 (PN-16) including PP-R plain/brass fittings in trenches/walls/ceiling or laying in floors complete of size outer dia 50 mm including taking down of old existing GI pipe 40 mm dia and fittings complete all as specified and directed by Engr-in-Charge | 40.1 | RM | 11 | ₹441.1 |
| - | Supply and laying/fixing of 3 layer (inner antimicrobial, outer UV stablised) ISI marked, IS 15801, PP-R pipes SDR 7.4 (PN-16) including PP-R plain fittings in trenches/walls/ceiling or laying in floors complete of size outer dia 63 mm including taking down of old existing GI pipe 50 mm dia and fittings complete all as specified and directed by Engr-in-Charge | 713 | RM | 10 | ₹7,130 |
| - | Supply and fix Cast Iron Sluice Valve of size 80 mm nominal bore, PN 1.6, as per IS:14846 with flanged ends, hand wheel operated, stainless steel stem including necessary packing material, GI bolts, nuts and washers etc complete including taking down old existing sluice valve all as specified and directed by Engineer-in-Charge. | 9 | Each | 100 | ₹900 |
| - | Supply and fix Cast Iron Sluice Valve of size 100 mm nominal bore, PN 1.6, as per IS:14846 with flanged ends, hand wheel operated, stainless steel stem including necessary packing material, GI bolts, nuts and washers etc complete including taking down old existing sluice valve all as specified and directed by Engineer-in-Charge. | 2 | Each | 53 | ₹106 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_894051.xls
BOQ • 0.27 MB
8220_Tender.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .