| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹44.9 L+₹4.4 L (11.0%)Rejected-AOC | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹45.6 L+₹5.1 L (12.7%)Rejected-AOC | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | Rejected-Technical 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | - | Rejected-Technical Unenlisted contractor having nearly twice the work load limit |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
18 Apr 2022, 6:00 pmClosed
G
Garrison Engineer Military engineer services Roorkee
PROVN OF OPEN PARKING SHED FOR 30 SCOOTERS AT MAIN ENTRANCE OFFICE AND SPL REP TO PLASTERING FLOORING ROOF DOORS WINDOWS AND ELECTRIC POINTS IN BLDG NO. 11 1-10 OF JUBLI MANDI AT A LINE AT RTS AND DEPOT SHARANPUR UNDER GE ROORKEE
2022_MES_510431_2
8392/116/E8
Open Tender
Civil Works
Item Rate
180 days
Saharanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (MES) Roorkee
₹97,000
Yes
1 Jun 2022
28 Mar 2022
20 Apr 2022
29 Mar 2022
18 Apr 2022
5 Apr 2022
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m deep for foundations etc or for shafts, wells, cesspits, manholes, pier holes, laying of pipe line etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone agregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) in foundation, footing, plinth beam, bases of columns and similar works complete all as specified and directed.
Use and waste formwork to sides of concrete foundation, footing, bases of columns, sides and soffits (if any) of plinth beams and similar work (vertical or to batter) for rough finished flat concrete surfaces complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in Columns, pillars, piers and similar works complete all as specified and directed.
Use and waste formwork to sides of posts, struts, piers, columns and similar work (vertical or to batter) for rough finished flat concrete surfaces complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L mild steel TMT bars 6 to 8mm dia as in stirrups and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and directed .
M&L for brick work with old size sub class 'B' bricks in cement mortar (1:6), straight or curved on plan exc 6m mean radius complete all as specified and directed.
All as per item No. 11.00 above but except bricks Note:- Serviceable bricks retrieved from demolition to be reused
M&L for 40mm thick damp proof course in cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) mixed with and including water proofing compound @ 3% by weight of cement, laid to horizontal or vertical surfaces including necessary form work complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm with soft lose soil obtained from excavation complete all as specified and directed.
Removing excavated surplus soil at a distance n.ex5 50 m and deposting where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base, sub floor and the like complete all as specified and directed.
Taking down cement or cement lime plaster on brick walls or concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 12mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete work surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of colour wash over one coat of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats cement based paint over one coat alkali resistant priming paint complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings nexc 15 cm thickness (below or above GL) complete all as specified and directed.
M&L for non-skid ceramic joint free coloured (Digital colour) tiles 7 to 8 mm thick, area of each tile exc 0.11 Sqm and n.exc 0.18 Sqm, laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) as in flooring, set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
ML for plain cement concrete (1:2:4) type B-1 (using 20 mm grade stone aggregate) as in cills, copings, bed blocks and the like, weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, laid in panels and finished even & smooth without using extra cement complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4) type B2 (using 40 mm graded stone aggregte) as in flooring, hardstanding and the like, laid in alternate bays, finished even and smooth without using extra cement with spike rolling to surfaces or making impresson of expended metal while the concerete is green complete all as specified and directed.
M&L for 75mm thick PCC (1:2:4) type B2 (using 40 mm graded stone aggregte) as in flooring, hardstanding and the like, laid in alternate bays, finished even and smooth without using extra cement with spike rolling to surfaces or making impresson of expended metal while the concerete is green complete all as specified and directed.
S&F rolled mild steel work as in tubular trusses, purlins, rafters etc including special shaped washers using ERW or induction butt welded tubes conforming to IS:1161- 1979 grade St-240 complete all as specified and directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour, having tensile strength 550 Mpa, laid and fixed in roof covering /wall cladding with self tapping screws as per manufacturer's instructions complete all as specified and directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheet of any colour, having tensile strength 550 Mpa, laid and fixed in roof covering /wall cladding, ridges and the like with self tapping screws as per manufacturer's instructions complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in sub base, sub floor for hardstanding and the like complete all as specified and directed.
M&L for 60 mm thick precast machine pressed cement concrete interlocking paver blocks of any shape and size, conforming to IS 15658-2006 using M-35 grade cement concrete with grey cement and pigment, laid dry over and including a layer of 25 mm thick of fine dry sand cushioning complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in kerbs, rounded or chamefered on edges including necessary form work complete all as specified and directed.
Dismantling/taking down asbestos (corrugated, semi-corrugated etc) sheets in roof covering including ridges of any description complete all as specified and directed.
Taking down wall/ceiling boards of any thickness and description incluing cover fillets complete all as specified and dirrected by Engineer-in-Charge.
Dismantling timber scnatlings in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section complete all as specified and directed.
S&F mild steel work as in purlins, rafters, wind ties, fixed independently for roof including securing bolts, flat iron fillets (for securing weather boarding with screws or bolts and nuts) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F 0.63 mm thick corrugated galvanised iron sheeting with two corrugations side lap, fixed with coach screws and washers in roofs, walls etc with grade of zinc coating 275 complete all as specified and directed.
S&F 0.63 mm thick plain galvanised iron sheeting, fixed as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified and directed.
S&F powder coated everest ceiling grid system of grid size 600x600 mm, fixed to walls with rawl plugs and screws or hanged to roof members with 3 mm dia GI wire comprising main tee of size 38 mm x 24 mm x 0.30 mm, cross tee of size 28 mm x 24 mm x 0.40 mm including S&F calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (fixed with staples to snap grid as in ceiling complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frame) n.exc 1.5 Sqm each complete all as specified and directed.
M&L factory made for pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
M&L for factory made pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed.
S&F mild steel work as in bands, straps, stays, hold fasts, supports, clamps, wall ties hooks including nut and bolts etc, conforming to Fe-290 Gde E-165 including welding etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in levelling course to receive floor finishes, filling in pressed steel frames and similar work including necessary form work complete all as specified and directed.
S&F factory made 30 mm thick flush shutters, solid core construction with block board core and plywood face panels, water / weather proof type on both sides complete all as specified and directed.
S&F factory made 35 mm thick IInd har wood plain framed, panelled shutters (two panels) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rails and stiles as per IS 1003 (Part I ), kiln seasoned and chemically pressure treated and fitted to chowkat complete all as specified and directed.
S&F factory made 35mm thick IInd class hard wood glazed or skeleton door shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, sizes of members of shutter as specified in SSR Part-I, Section 8, clause 8.20(a) complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, medium weight cold rolled (ISI marked), fixed to wooden door chowkat with screws complete all as specified and directed.
S&F 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 200mm size aluminium anodised barrel tower bolt of extruded section, fixed in position with screws complete all as specified and directed.
S&F 150mm size extruded aluminium alloy hanldes fabricated type, fixed in position with screws complete all as specified and directed.
S&F factory made steel windows with side hung shutters including frame, box type hinges, steel handles and steel peg stay with glazing bars dovetailed or welded complete all as specified and directed.
S&F factory made steel windows with side hung shutters including frame, box type hinges, steel handles and steel peg stay without glazing bars complete all as specified and directed.
S&F MS framed work such as grills, gratings with ends of bars shouldered and or riveted or forged into spikes, framed guard bar, barred iron door, ladders, hold fast, framed balusters, walk ways, railings, frame work of water tank and similar work conforming to Fe 290 Gde E165 complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality, fixed to steel frame with oil putty and glazing pins/spring clips in square n.exc 0.5m each pane complete all as specified and directed.
S&F galvanized mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking down old unserviceable point wiring of any type and description including all fittings and fixtures such as switches, sockets, holders, ceiling rose, fan regulator etc and making good disturbed surfaces to match the existing surfaces complete all as specified and directed.
M&L for Point wiring concealed type with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area, drawn through & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) and 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes of 1.6 mm thick (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including plastic laminated bakelite sheet cover of hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screws, washers etc for the following:-
One light point controlled by one, one way switch
One fan point controlled by one, one way switch
One 3/5 pin socket outlet 5 Amp on the same board with other switches.
One 3/5 pin 5 Amps socket outlet on indepandent board.
All as per item No 64.00 above but with 2.5 Sqmm (nominal area) FRLS cable PVC for 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor of green colour for earth continuity.
S&F LED tube light fitting 1x18/20 Watt box type with bipin holders connector block complete with all accessories internally prewired including connecting up with three core single wire and 01 No. 18/20 watt LED tube rod complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
S&F Ceiling rose 3 phase/PVC/polycarbonate, insulated body complete all as specified and directed.
S&F stepped type electrronic fan regulator flush type complete all as specified and directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with and including 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
Taking down old sub main wiring of any description and S&F new sub main wiring with two runs of single core (FRLS) PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 Sqmm LT, 1100Volt grade, drawn through and including PVC non metallic conduit of 20mm dia or other appropriate dia with all accessories and fittings and one run of 4.0 Sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall be deemed to be included in quoted rates and shall not be measured separately complete all as specified and directed. Note :- (i) Two runs of 4 Sqmm cable & one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. (ii) Cable required for connection to DBs shall be deemed to be included in unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit pipe. (iv) Extra length of cable required for connection to MCBs shall be deemed to be included in unit rate.
S&F new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting suitable for 25 watt capacity LED lamp with and including all accessories duly pre-wired, fixing bracket made out of GI pipe medium grade 1.20 m long of suitable dia bent to shape with suitable size mild steel clamps (Two Nos.) of flat iron 50 X 6 mm with nut, bolts & washers as required at site for fixing of street light on LT pole / wall complete all as specified and directed.
Taking down old unserviceable building security light fitting of any description and S&F new building security light fitting with new generation energy saving environment friendly long life versatile pressure die-cast aluminium IP5 roadway luminaire with high power LEDs as light source and exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 25 watt capacity LED including all accessories duly pre-wired and fixing on existing bracket with nuts, bolts and washers as required at site for fixing on LT pole//wall and connecting up with & including flexible wire of suitable size complete all as spd and directed.
Taking down old unserviceable bulk head light fitting of any description and S&F new bulk head fittings IP-65, surface mounted comprising LED luminaire 6.5W of high brightness complete all as specified and directed.
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral conforming to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed.
Taking down old unserviceale main switches, distribution boards of any description including MCBs etc and S&F new double door MCB distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 12 way IP 43 with 200 Amps rated copper bus bar neutral bar, earth bar, triple pole and neutral confirming to IS : 13032-1991DB, 415 volts, flush to wall complete all as specified and directed.
Taking down old unserviceale main switches, distribution boards of any description including MCBs etc and S&F new double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral 4 way conforming to IS:13032-1991DB, 240 Volts 200 amps rated busbar complete all as specified and directed.
S&F MCB single pole 6 to 32 Amps 240 Volt 'B' curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area including suitable size copper lugs complete all as specified and directed.
S&F MCB double pole 40 Amps 240 Volt, 50 Hz, 'B' curve with breaking capacity 10 KA including suitable size copper lugs complete all as specified and directed.
S&F MCB four pole 63 Amps, 415 Volts, 'B' curve, breaking capacity 10 KA, IP 20 transparent label holder fully insulated safety shutters suitable for cable upto 35 Sqmm cross sectional area including suitable size copper lugs complete all as specified and directed.
Dismantling of old unserviceable earthing of any description and making good the disturbed surfaces of soil and M&L for providing new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically in pit of depth not less than 2.25 meter below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C-1 for chamber of internal size not less than 300x300x300mm with cover made of RCC (1:2:4) type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways and MS frame of angle iron 40x40x5mm complete all as specified and directed. Note: The unit rate includes earth strip and protection pipe up to (maximum 7.5 meter from earth plate) earth point/test point.
BLANK
Taking down/up of existing un-serviceable UG cable of 25 Sqmm size of any description and Supply and laying cable PVC insulated aluminium multistranded sheathed 1100 volts grade armoured heavy duty of size 25 sqmm 3.5 core complete all as specified and directed and directed.
Supply and laying cable PVC insulated aluminium multistranded sheathed 1100 volts grade Armoured heavy duty of size 16 sqmm 2 core complete all as specified and directed.
M&L for dry clean sand filling in trenches around underground cables for cushioning, complete all as specified and directed. Note: Depth of sand shall be measured after punning complete all as specified and directed.
Supply and laying old size sub class 'B' bricks as in cable protection, laid dry, flat, perpendicular across the cable in trenches complete all as specified and as directed.
Supply and laying 40mm dia GI tubing, light grade with all fittings for cable protection including GI clamps, nut & bolts and washer etc complete all as specified and directed.
Removal of house service bracket from the wall with nuts, bolts and clamps and making good the surfaces to match the existing surfaces complete all as specified and directed.
RAM PRAKASH AND ASSOCIATES
M/s Inderlal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .