| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-AOC Lowest Tender | |
| 2 | L2₹47.0 L+₹1.5 L (3.27%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance Other then lowest bidder | |
| 3 | L3₹47.9 L+₹2.4 L (5.26%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-Finance Other then lowest bidder | |
| 4 | L4₹51.9 L+₹6.4 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Other then lowest bidder | |
| 5 | L5₹53.3 L+₹7.8 L (17.2%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-Finance Other then lowest bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
1 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
PROVN OF ENHANCEMENT OF CMD BY GEB FOR ELECTRIC SUPPLY FROM 300 KW TO 450 KW AT WADSAR UNDER GE AF CHILODA
2023_MES_630673_1
82175/CHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chiloda
As per tender document
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹99,000
Yes
12 Feb 2024
1 Dec 2023
8 Jan 2024
1 Dec 2023
1 Jan 2024
18 Dec 2023
2 Dec 2023 - 15 Dec 2023
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed.
Removal of excavated material at a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point in soft / loose soil complete all as directed.
M&L Providing PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation for erection of poles/ stay assembly complete all as specified and as directed by Engineer-in-Charge.
M&L Providing PCC 1:3:6, type C-1 using 20 mm graded stone aggregate as in coping to pole etc., including necessary form work complete all as specified and as directed by Engineer-in-Charge.
M & L Brickwork with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified
Renewing cement concrete tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete
M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including demolition complete all as specified
M&L Cement concrete tiles with grey cement and pigment 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished including demolition complete all as specified
M & L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces
M& L GI Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed .
S&F Disc type insulator, porcelain, vitreous 150 mm high and 150 mm dia ball and socket type, white, brown or green 'Two in series' assembly for tension with tension clamps for conductors, suitable for working pressure 11000 volts grade complete all as specified and directed by Engineer-in-Charge.
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade complete all as specified and directed by Engr-in-Charge.
S&F HT 11 KV Air break switch, gang operated and drop out fuse unit of 6 insulators complete with all accessories, mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 400 Amps including GI pipe of suitable size, clamps, nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge.
S&F 11 KV Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified
S&F Cable jointing kit for 11 KV grade In door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured , aluminium conductor cable of size 120 sqmm complete all as specified.
S&F Cable jointing kit for 11 KV grade out door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE , armoured , aluminium conductor cable of size 120 sqmm complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.complete all as specified
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with standard aluminium conductor of,size 16 sq mm 2 core complete all as specified
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with standard aluminium conductor of,size 16 sq mm 4 core complete all as specified
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with standard aluminium conductor of size 25 sq mm 2 core complete all as specified
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with standard aluminium conductor ofsize 25 sq mm 3.5 core complete all as specified
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with standard aluminium conductor of size 3.5 core 150 sq mm complete all as specified
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 3.5 core 300 sq mm complete all as specified
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm complete all as specified
M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth strip 32 x 6mm by means of bolts, nuts check nuts and washers of galvanised iron earth strip protection by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . Any variation in length shall be adjusted through deviation order (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper strip 32x 6 mm complete all as specified
M&L Coarse aggregates, Grading l, 90 to 40 mm size or grading 3, 50 to 20 mm size granite for spreading on ground for Four/Two pole structure.complete all as specified
M&L Taking down of existing RMU and removing the same to the MES yard as directed by Engr in Charge
Supply, install, testing and commissioning of HT 11 KV, 3 Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Indoor LHS Extensible Fixed Type , RMU (Ring Main Unit) 4-way comprising of 02 Nos 630 Amps, manually operated Load Break Switch & 02 Nos. manual charging fixed-type Vacuum Circuit Breaker, inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min. thickness 2.5 mm with IP 67 Degree of Protection and enhanced BIL of 75kVp internally to manage voltage surges. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFL 21kA/1 sec for tank as per IEC62271-200. RMU shall have on-iterepairability features such as site replaceable bushing/coupling/mechanism and gas refilling at site. The earthing busbar shall be provided inside each cable compartment for solid earthing of Cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fitting as required at site. 02 Nos. Incoming and Outgoing Load Break Switch module consisting of following accessories : 11kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 21kA/3-sec, Making Capacity - 52kAp Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 No.for Incoming LBS Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future.
Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live-condition, Right angle boots (push on type) Suitable site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 02 Nos. Outgoing Breaker module consisting of following accessories :11kV, 630A fixed-type Vacuum Circuit Breaker module for making and breaking of fault current along with disconnector +Earth Switch of full making capacityShort time current - 21KA/ 3 sec, Making Capacity - 52kApAuxiliary contacts - 1NO + 1NCStored Enegry mechanism with manual spring-charging, associated closing/tripping coils, integrated non removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism Interlocked Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3X). Safety interlocked to prevent access to cable termination in live condition.Right angle boots (push on type)Numerical based self-powered OC+EF Protection Relay, providing Over Current (min. setting 20%), Earth-Fault (min. setting: 10%)03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc.Cl.5P10), installed away from bushings to prevent saturation of core.Suitable site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for
installation/testing/replacement purposes.Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCBCapacitive voltage indication fixed type systemMechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged i Capacitive voltage indication fixed type VPIS 9-15 kV ii Necessary interlocking arrangement for safety and operations iii One No. Operation Handle for Manual Operation and one no. manometer iv Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. v Above switchgear shall confirm to all relevant IEC/IS Standards. vi Vacuum interrupter should be of same make as RMU vii Cable bushing should be replaceable at site. viii Minimum 5 module should accommodate in one tank to avoid multiple coupling at site.
Supply, install, testing and commissioning of HT 11 KV, 3 Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Outdoor LHS Extensible Fixed Type (IP54), RMU (Ring main unit) 4-way comprising of 02 Nos 630 Amps, manually operated Load Break Switch & 02 Nos. manual charging fixed-type Vacuum Circuit Breaker, inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having min. thickness 2.5 mm with IP 67 Degree of Protection and enhanced BIL of 75kVp internally to manage voltage surges. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFL 21kA/1 sec for tank as per IEC62271-200. RMU shall have on-iterepairability features such as site replaceable bushing/coupling/mechanism and gas refilling at site. The earthing busbar shall be provided inside each cable compartment for solid earthing of Cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fitting as required at site. 02 Nos. Incoming and Outgoing Load Break Switch module consisting of following accessories : 11kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 21kA/3-sec, Making Capacity - 52kAp Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 No.for Incoming LBS Spring-assisted snap-action mechanism driven via shaft that remains un-inhibited after motorization, if required in future.
Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live-condition, Right angle boots (push on type) Suitable site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. Cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 02 Nos. Outgoing Breaker module consisting of following accessories :11kV, 630A fixed-type Vaccum Circuit Breaker module for making and breaking of fault current along with disconnector+Earth Switch of full making capacityShort time current - 21KA/ 3 sec, Making Capacity - 52kApAuxiliary contacts - 1NO + 1NCStored Enegry mechanism with manual spring-charging, associated closing/tripping coils, integrated non removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism Interlocked Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3X). Safety interlocked to prevent access to cable termination in live condition.Right angle boots (push on type)Numerical based self-powered OC+EF Protection Relay, providing Over Current (min. setting 20%), Earth-Fault (min. setting: 10%)03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc.Cl.5P10), installed away from bushings to prevent saturation of core.Suitable site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for
installation/testing/replacement purposes.Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCBCapacitive voltage indication fixed type systemMechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged i Capacitive voltage indication fixed type VPIS 9-15 kV ii Necessary interlocking arrangement for safety and operations iii One No. Operation Handle for Manual Operation and one no. manometer iv Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. v Above switchgear shall confirm to all relevant IEC/IS Standards. vi Vacuum interrupter should be of same make as RMU vii Cable bushing shall replaceable at site. viii Minimum 5 module should accommodate in one tank to avoid multiple coupling at site.
Supply and laying of DWC HDPE pipe of SN4 category conforming to IS (Latest version) including accessories like HDPE snap fit coupler with neaoprene 'O' ring complete of size100 mm inner dia ( for protection of 300 sqmm LT and 120 sqmm HT cable all as specified Make : ALOM POLY EXTRUSIONS LTD (TELECORR) or equivalent make as approved by GE
Supply and laying of DWC HDPE pipe of SN4 category conforming to IS (Latest version) including accessories like HDPE snap fit coupler with neaoprene 'O' ring complete of size 63 mm inner dia ( for protection of 150/120 sqmm UG cable all as specified Make : ALOM POLY EXTRUSIONS LTD (TELECORR) or equivalent make as approved by GE
Supply and laying of DWC HDPE pipe of SN4 category conforming to IS (Latest Version) including accessories like HDPE snap fit coupler with neaoprene 'O' ring complete of size 38 mm inner dia ( for protection of 25/16 sqmm UG cable all as specified Make : ALOM POLY EXTRUSIONS LTD (TELECORR) or equivalent make as approved by GE
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps.
M&L Taking down of 2 pole structure and associated items
Supply & erect RSJ pole 100 x 116 mm 11 meter approx weight 200 kg , 85 micron GI coating consisting of pole with , PCC foundation & cross arms etc to construct two/four pole structure for installation GOD,CT,LA,DO fuse etc complete with drilled necessary holes/ fabrication all specified and directed . Note - Excavation, PCC ,cross arms, GOD,LA DO Fuse shall be paid separately under respective item.
S&F Cable looping box for street light / flood lights/security camera complete with enclosure and bus-bar.
M & L Boring of holes up to 80 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique/manual complete all as directed by Engineer-in- Charge. Note:- Pipe for protection of cable shall be measured and paid separatelyunder respective item
M/s SK Traders
Abhishek Enterprises
Sukhi Electricals
ALBA AC AND REF SERVICES
M/s Matadeen Ramchandra Agarwal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .