Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹3,862
Closing Date
17 Nov 2023, 6:55 pmClosed
Executive Engineer Mech. Irrig. Div. Baramulla
Mech. Irrig. Div. Baramulla
Repairs to 100kva electric substation at Lift irrigation cum dewatering scheme Magraypora 1st of MISD Pattan.
2023_IFC_234153_2
e NIT 19 of 2023-24
Open Tender
Repair and Maintenance Works
Item Rate
7 days
Pattan
Please refer Tender documents.
7 documents required · 7 mandatory
₹100
Yes
Executive Engineer Mech. Irrig. Div. Baramulla
₹3,862
Yes
20 Nov 2023
2 Nov 2023
18 Nov 2023
2 Nov 2023
17 Nov 2023
2 Nov 2023
Amount
Providing and erection of steel tubular poles 09 m long (410-SP-33) with base plate 350mm×350mm×05 mm eight feet apart for mounting of 100 KVA substation and tapping of HT line.
Cement bottoming of electric Poles 3ft below ground level and 1 ft above ground level and 2feet dia in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). Approx. qty 0.5 cum per pole including, excavation, centering, shuttering, curing, carriage, etc. complete job.
Painting of pole with one coat of Red-oxide and two coats of Aluminium paint (including cost of paint).
Providing and fixing of Guy wire 7/2.15mm including guy insulators, guy rods with guy assembly complete.
Providing and fitting of ISMC 75, 8rft in length each (05 no). The nut and bolts required for fitting of channels shall be provided the firm. The channels are required for fitting of link set and drop out set on the poles.
Providing and fitting of ISMC 100, 8rft in length each (02 no). The nut, bolts, clamps required for fitting of channels shall be provided by the firm. The channels are required for placing of transformer.
Tapping of HT line by way providing and fitting of channel iron cross arms 03 feet long fabricated out of ISMC-75 (02 no.) and angle iron braces 03 feet long fabricated out of ISA 40x40x5 mm (02 no.) including nuts and bolts.
Providing, installation and fixing of 11 KV link set and dropout set with nuts, bolts, washer, clamps as per the latest specifications and site requirements.
Providing and fitting of heavy duty post type lightening arrestor set.
Providing and installation of Maintenance free Chemical Earthing using Electrode of size 25mm dia, 02.50 meter long connected with 25X5mm GI connection strip of 4m length from the electrode upto plant room complete with excavation, civil works, inspection chamber in brick work with cast iron cover of 12" x 12", chemical earthing compound, GI nuts bolts etc. Complete job as per the latest relevant IS code. The voltage between Neutral & Earth not to exceed 0 volts & IR value less than 1 ohm.
Providing and fitting of GI earthing strip of size 25 mm X5 mm including installation for connecting various electrical equipments of the pump station to earthing electrode including GI nuts bolt set. Complete job.
Providing and fitting of 11kva Pin insulator.
Providing and fitting of 0.03 ACSR conductor on the HT poles from existing HT line to the newly created substation.
Providing, laying and fitting of 1.1 KV, 120 mm2 , 3.5 core Aluminum XLPE insulated armoured cable of reputed make from substation to MCCB with each terminal of cable duly thimbled, crimped and properly insulated using heat shrink sleeves and suitable sized Al thimbles. The cable is to be laid underground in PVC pipe by way of earth excavation using manual labour and then refilling of trench after laying of cable.
Shifting of 100 KVA HT transformer from the dilapidated sub-station to newly created substation. The job also includes P/f of transformer belt (clamped).
Providing and fitting of 7.5 HP DOL starter of L&T/Bentex/Kilburn make.
Providing, installation, testing and commissioning of 80HP (L&T/Bentex/Kilburn make). OISD Starter, mechanically operated, working on 450±10% AC voltage supply, 50HZ, working on star delta principle. The starter shall be fitted with heavy duty copper bush rods 6 nos. 3 for incoming and 3 no’s for outgoing, and auto tripping system. The starter shall be fitted with heavy duty copper points, both moving and fixed. The complete assembly shall be housed in a suitable container fabricated out of 14 gauge MS sheet with easy inspection cover. The starter shall be first filled with starter oil (upto required level) of high grade and low viscosity. The starter shall be mounted with nuts and bolts for proper fixing on panel board and tested on full load at site.
Providing and fitting of 20W Led light with IP 65 rating. The Job includes wiring of the light with 1sqmm FRLS copper wire and 6A MCB with gang box for ON and OFF operation.
Providing of LED Lantern with Twin Charging mode – Charging Cable or Solar Panel (inclusive of panel) (Syska/ Havells/ Andslite/ Philips)
Providing of HT rubber gloves pair, HT link rod.
Providing and fitting of Analogue voltmeter (0-500V) of AE/Rishab make.
Providing and fitting of Ammeter (0-200 A) with CT coils.
Providing and fitting of ISA 25x25x3 required for urgent repairs to CGI pump shed.
Providing and fitting of 26 gauge colored galvanized CGI Ridge 10 feet long.
Providing and fitting of fitting of 26 gauge CGI sheet.
The firm has to get the inspection certificate from inspection division (if demanded by the PDD) and the work should be carried out as per the relevant guidelines.
SUNRISE TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .