Executive Engineer (Electrical)
4th Floor, Poura Bhavan, Bidhannagar Municipal Corporation
Emergent work for restoration of damage cable and damage steel tubular poles at CD Block and adjacent area within Ward no 40 under BMC.
2026_MAD_1013143_1
NIT No 33/PHE(EM)/BMC (1st Call) Dated - 23-02-2026
Open Tender
ELECTRICAL WORKS M/R
Percentage
10 days
Bidhannagar Municipal Corporation
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹15,270
13 Mar 2026
23 Feb 2026
13 Mar 2026
24 Feb 2026
11 Mar 2026
25 Feb 2026
Particulars
Supply & Delivery of the following sizes 1.1KV grade XLPE insulated aluminium conductor armoured cable as per IS 7098 (Part-I) 1988 with up to date ammendments. (a) 4 core 16 sq.mm cable.
Supply & Delivery of the following sizes 1.1KV grade XLPE insulated aluminium conductor armoured cable as per IS 7098 (Part-I) 1988 with up to date ammendments. (a) 4 core 10 sq.mm cable.
Micro-tunnelling including supply of HDPE pipe 40 mm dia. As per appropriate specification in single length for each indivisiual tunnel.
Laying of one No cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth , with brick protection on the top of the cable with 8(Eight) no of bricks per metre, including filling the space between the brick and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Dismantling of steel tublar pole /C.I Pole in C.C foundation including excavated filling of holes restoring surface lading at site and unloading another site and caring thr same for shifting of existing pole as per direction of EIC.(Including dismantling of LED fittings)
Repairing the existing steel tubular pole at the bottom portion by insertion of M.S. Pipe sleeve uptodia 165mm length 762mm. of 5-6mm. thickness to match the original pole by means of electric welding including painting the repaired portion with red oxide including of all tools & _ tackles as per direction of E.I.C.
Erection of single steel tubular pole 9 mtr, length with base plate on C.C foundation having 600 x 600 x 150 mm thick base block below base plate with hard jhamaincluding c.c. by (6:3: 1 of 0.6 x 0.6 x 1.70) mtr. Below G.L. and net cement complete and providing G.I. earth bolt of 2.7 mtr. From bore including carriage of pole (pole will be supplied departmentally).
S & F sintex make SMC/FRP waterproof type looping cable box on newly erected pole and in place of damaged pole boxes having size 240 x 130 lace of damaged pole boxes having size 240 x 130 x 95 mm depth, hinged front cover & kit –Kat fuse unit 1 no. NL, on insulator, 1 no. 4 Way bacelite connector, provision for 2 nos. compression brass gland for upto 3 core 16 sq.mm PVC, AI cable and having lined with rubber gasket front cover with brass machine screw, etc. earthing terminal with log on steel tubular pole near base including supply & fixing suitable pole near base including supply & fixing suitable MS clamps with nuts & bolts etc. complete in all respect as per direction of E.I.C
Wiring in 1.1 KV grade single core standerd 'FR' PVC insulated & unsheathed copper wire ( Brand approved by EIC) of following sizes in 25mm PVC casing -capping(Precision make) incl. necy.PVC clips, Fittings etc. 2x22/0.3 (1.5 sqmm)
Earthing the steel tubular pole with 19 mm dia x 1.0 mtr length G. I rod and 1 no 4swgGl wire up to 4 mtr length 15 mm x 65 mm long Gloat with double nuts and washers including supply. Of all required materials as per direction of E.I.C.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC Armoured cables as below. For 4 core 16 Sq.mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc. and making connection to switch, BDB and BBC etc. 4 core 16 sqmm cable
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. (a) Up to 9 Mtr. Long pole (i) 1st coat of aluminium paint over 1 coat of RO priming.
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tendernotice_2.pdf
PDF • 1.22 MB
BOQ_2488667.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .