| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Tender | |
| 2 | L2₹46.8 L+₹1.1 L (2.38%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST TENDER | |
| 3 | L3₹47.0 L+₹1.3 L (2.81%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Rejected-Finance NOT LOWEST TENDER | |
| 4 | L4₹47.0 L+₹1.3 L (2.85%)Rejected-Finance 10 67 1 CHINNAMUSHIDIWADA PENDURTHI VISAKHAPATNAM ANDHRA PRADESH 530051 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530051 | L4 | Rejected-Finance NOT LOWEST TENDER | |
| 5 | L5₹47.2 L+₹1.5 L (3.29%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L5 | Rejected-Finance NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | GVR ENGINEERING WORKS L2 | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L8 | RATNA ENTERPRISES L9 | MSN ENGINEERING WORKS L3 | SAI ENGINEERING WORKS L1 | VENKATESWARA ENGINEERS AND CONTRACTORS L6 | M/S CHANDRA ENGINEERS AND CONTRACTORS L5 | SIVA MARUTHI ENTERPRISES L4 | Prasad and Suresh Constructions L10 | SVG SUPPLIES L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE (a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after. (b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE | |||||||||||||
| 1.01NOTES(Contd---) (e)The breakdown/Leakeges should be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues: Size of Pipe Time limit to attend Breakdown & Completion Upto 50mm 6 Hrs 50mm-100mm 8 Hrs More than 100mm 12 Hrs (f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement. (g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multi-storyed Buildings under AoR of GE (U-II). | |||||||||||||
| 2.00 | Taking down carefully the existing pump motor set of capacity 20 HP to 60 HP from foundation by putting dummy plate at suction and delivery line properly, making good the foundation by PCC as required and shift to MES store yard, complete all as specified and directed. | 4 | Each | 4,500 ₹18,000 | 6,000 ₹24,000 | 5,000 ₹20,000 | 4,000 ₹16,000 Lowest | 5,500 ₹22,000 | 5,500 ₹22,000 | 4,500 ₹18,000 | 5,000 ₹20,000 | 5,000 ₹20,000 | 5,500 ₹22,000 |
| 3.00 | Taking down carefully the existing pump motor set of capacity 20 HP to 30 HP from foundation by putting dummy plate at suction and delivery line properly, making good the foundation by PCC as required including shifting to new location, installation, testing with all fittings, flange, nuts, bolts etc, complete all as specified and directed. | 2 | Each | 8,500 ₹17,000 | 9,500 ₹19,000 | 9,000 ₹18,000 | 6,000 ₹12,000 Lowest | 10,000 ₹20,000 | 9,500 ₹19,000 | 8,500 ₹17,000 | 9,000 ₹18,000 | 9,000 ₹18,000 | 10,000 ₹20,000 |
| 4.00Taking down carefully the existing motor of the following capacities of pump sets from foundation bed for servicing by removing the coupling, cleaning the motor & starter body with cleaning agent, varnishing, improving the insulation values, reassembling and re-installing the motor with necessary bolts, nuts and washers and connecting the pump set, complete all as specified and directed:- Note :- Bearings shall be measured and paid separately under relevant item of BOQ. | |||||||||||||
| 4.01 | Up to 5 HP | 3 | Each Job | 2,500 ₹7,500 Lowest | 2,700 ₹8,100 | 2,500 ₹7,500 Lowest | 3,000 ₹9,000 | 3,500 ₹10,500 | 2,700 ₹8,100 | 2,500 ₹7,500 Lowest | 2,500 ₹7,500 Lowest | 2,500 ₹7,500 Lowest | 3,500 ₹10,500 |
| 4.02 | 7.5 to 10 HP | 2 | Each Job | 4,300 ₹8,600 Lowest | 4,300 ₹8,600 Lowest | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,300 ₹8,600 Lowest | 4,300 ₹8,600 Lowest | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,500 ₹9,000 |
| 4.03 | 12.5 to 30 HP | 2 | Each Job | 4,700 ₹9,400 Lowest | 4,700 ₹9,400 Lowest | 4,700 ₹9,400 Lowest | 8,000 ₹16,000 | 9,500 ₹19,000 | 4,700 ₹9,400 Lowest | 4,700 ₹9,400 Lowest | 4,700 ₹9,400 Lowest | 4,700 ₹9,400 Lowest | 9,500 ₹19,000 |
| 4.04 | 40 to 75 HP | 4 | Each Job | 7,500 ₹30,000 | 7,500 ₹30,000 | 8,000 ₹32,000 | 6,000 ₹24,000 Lowest | 10,000 ₹40,000 | 7,500 ₹30,000 | 7,500 ₹30,000 | 8,000 ₹32,000 | 8,000 ₹32,000 | 10,000 ₹40,000 |
| 4.05 | 100 to 170 HP | 3 | Each Job | 10,000 ₹30,000 | 10,000 ₹30,000 | 10,000 ₹30,000 | 12,000 ₹36,000 | 15,000 ₹45,000 | 8,500 ₹25,500 Lowest | 10,000 ₹30,000 | 10,000 ₹30,000 | 10,000 ₹30,000 | 15,000 ₹45,000 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
10 Sept 2025, 6:00 pmClosed
Garrison Engineer Utility-II Visakhapatnam
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
REPAIRS/ MAINTENANCE AND REWINDING OF MOTOR/PUMPS AT M-GEDDA FILTRATION PLANT, 104 BPH, MEGHADRIPETA AREA AND OTHER CONNECTED MICS WORKS UNDER GE (U-II) VISAKHAPATNAM
2025_MES_726472_1
8105(A)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-II Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Utility-II
₹88,000
Yes
11 Oct 2025
19 Aug 2025
11 Sept 2025
19 Aug 2025
10 Sept 2025
5 Sept 2025
19 Aug 2025 - 26 Aug 2025
Amount
NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE (a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after. (b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE
NOTES(Contd---) (e)The breakdown/Leakeges should be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues: Size of Pipe Time limit to attend Breakdown & Completion Upto 50mm 6 Hrs 50mm-100mm 8 Hrs More than 100mm 12 Hrs (f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement. (g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multi-storyed Buildings under AoR of GE (U-II).
Taking down carefully the existing pump motor set of capacity 20 HP to 60 HP from foundation by putting dummy plate at suction and delivery line properly, making good the foundation by PCC as required and shift to MES store yard, complete all as specified and directed.
Taking down carefully the existing pump motor set of capacity 20 HP to 30 HP from foundation by putting dummy plate at suction and delivery line properly, making good the foundation by PCC as required including shifting to new location, installation, testing with all fittings, flange, nuts, bolts etc, complete all as specified and directed.
Taking down carefully the existing motor of the following capacities of pump sets from foundation bed for servicing by removing the coupling, cleaning the motor & starter body with cleaning agent, varnishing, improving the insulation values, reassembling and re-installing the motor with necessary bolts, nuts and washers and connecting the pump set, complete all as specified and directed:- Note :- Bearings shall be measured and paid separately under relevant item of BOQ.
Up to 5 HP
M&L for disconnecting and removing the existing defective Mono block / centrifugal pump/Submercible set motor of any make of following capacity from the installed position by putting dummy plate to suction and delivery removing the burnt out winding and re-winding the same with super enamelled copper wire of same gauge and same number of turns of existing make insulating winding with existing class of insulation varnishing baking up including replacement of base foundation nuts, bolts and re-installation of pump, testing to satisfactory performance, complete all as specified and directed:- Note :- Bearings, CI gland plates, Terminal block, shaft shall be measured and paid separately under relavent items of BOQ
Up to 5 HP
M&L for dismantling centrifugal pump coupled with electric motor 3 phase 415 volt, 50 Hz of following capacities from the foundation bed for repairs by removing the coupling and foundation bolts etc. dismantling the complete pump and separate the serviceable and unserviceable parts & replace the unserviceable parts/spares, reassembling and reinstall the pump with necessary bolts nuts and washers including cleaning and removing the scales and replacement of spare parts like impeller nut, keys, lock washer, gasket and greasing, reassembling coupling in position testing and commissioning in the pump set up to satisfaction level, complete all as specified and directed:- Note :- Supply Only Spare parts shall be measured and paid separately under relevant items of BOQ
Up to 5 HP
Taking down carefully existing motor and pump set of following capacities from the unserviceable bed and taking up the complete MS bed from the PCC and cleaning and levelling the bed including new PCC work including with fabrication of new MS bed by using new MS work with foundation bolts and nuts suitable for mounting/re-erecting the pump and motor after necessary minor repairs complete with two coats of existing colour painting over a coat of red oxide including testing and commissioning up to satisfaction level, complete all as specified and directed:-
Up to 5 HP
Supply only ball bearings suitable for Centrifugal and Monoblock pumps sets motors as existing at site, complete all as specified and directed:-
Up to 5 HP
Supply only CI gland plate high tension studs for Centrifugal / mono block pumps for the following capacity, complete all as specified and directed:-
Up to 5 HP
Supply only CI impeller suitable for centrifugal / mono block pumps for the following capacities, complete all as specified and directed:-
Up to 5 HP
Supply and fix 3 pole power contactor of existing model for AC 415 Volts, 50 Hz, 3 Phase suitable for electric motor of following capacity including removing existing unserviceable one from star delta starter, complete all as specified and directed:-
100 to 170 HP capacity.
50 to 75 HP capacity.
30 to 50 HP capacity.
20 to 30 HP capacity.
10 to 15 HP capacity.
Supply and replace burnt bimetal over load relay suitable for the following capacity of motor starters as existing at site, complete all as specified and directed:-
100 to 170 HP capacity (relay range 180-300 Amps)
40 to 75 HP capacity (relay range 45-75 Amps)
10 to 30 HP capacity (relay range 20-33 Amps)
Supply and replace Pump Shafts as per existing Model with necessary metal filling and machine suitable for the following capacity of pump sets, complete all as specified and directed:-
Upto to 5.0 HP capacity
7.5 to 10 HP capacity
12.5 to 20 HP capacity
25 to 35 HP capacity
40 to 60 HP capacity
75 to 110 HP capacity
120 to 170 HP capacity
Supply and replace Casing ring for Centrifugal / mono block pumps for the following capacity, complete all as specified and directed:-
10 to 15 HP capacity
25 to 35 HP capacity
40 to 60 HP capacity
75 to 100 HP capacity
110 to 170 HP capacity
Supply and fix in repairs terminal block of 6 terminals of the following capacities, complete all as specified and directed:-
Up to 7.5 HP Motor
10 to 15 HP Motor
20 to 40 HP Motor
50 to 75 HP Motor
100 to 170 HP Motor
Supply and fix in repair tapper roller bearing suitable for 50 HP to 75 HP Capacity, complete all as specified and directed.
Supply and fix in repair tapper roller bearing suitable for 100 HP to 120 HP Capacity, complete all as specified and directed.
Supply and fix in repair tapper roller bearing suitable for 150 HP to 170 HP Capacity, complete all as specified and directed.
Supply and fix in repairs pump set Star coupling made out of mild steel including drilling holes and suitable size of nuts, bolts for the following capacities of motors, complete all as specified and directed:-
Up to 5 HP
Supply and replace pump set rubber coupling complete for the following capacities of motors, complete all as specified and directed:-
Up to 5 HP
Taking down carefully the existing motor from the bed and taking up the VT pump by split opening the pump by removing coupling, line shaft and pump set and identifying the defects and replacing the worn-out parts as required and cleaning & over hauling the pump and commissioning, testing after repairs carry out & re-erecting complete Pump set for satisfactory performance, complete all as specified and directed. Note :- Supply only spare parts shall be measured and paid separately under relevant items of this schedule
Supply only following spare parts suitable for 30/ 40/50 HP VT water lubricated pump, complete all as specified and directed:-
Head shaft
Bearing holder assembly
Head shaft coupling
Stuffing box with bush complete
Line shaft bearing
M&L for Damaged column pipe by removing and cutting, welding & Threading and making leak proof repair, complete all as specified and directed.
Supply and fix MS ERW pipe heavy grade pipe on wall/ floor/ in ground of following sizes, complete all as specified and directed:-
300 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Supply and fix GI tubing medium grade of following sizes, complete all as specified and directed:- Note:- The Quoted rates shall be deemed to inclusive of all GI fittings like bends, sockets, unions, reducers and elbows etc., as required at site.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe of following size including dismantling the old one, complete all as specified and directed:-
20 mm dia bore
25 mm dia bore
40 mm dia bore
50 mm dia bore
80 mm dia bore
M & L for Construction of valves pit chamber having intermal dimention 120 cm x 120cm x 120 cm (internal height) using PCC (1:4:8) 40mm graded stone aggregate for foundation 15 cms. Thick, 23 cm tick wall in CM (1:4), 10mm tick rendering all around the brick work with 1:6 cement mortar, PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm tick MS top sheet cover with locking arrangement painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surpuls soil to a distance not exceeding 50 mtrs all as specified and includung demolition/ dismantling of existing valve chamber, complete all as specified and directed.
All as per Srl Item No. 27 of the above but dimention of 90cm x 90cm x 90cm complete.
M&L replacement of unserviceable sluice valve, spindle, and check nut by un screwing nut and bolts, gasket stuffing box and taking upper portion of sluice valve taking out u/s spindle check nut, cutting turning, polishing and preparing new SS spindle and check nut from the solid single SS piece of same length, dia of u/s spindle and check nut fixing the new spindle and check nut re assembling sluice valve replacement of u/s gasket nut and bolts and testing for the following bore sizes of sluice valve, complete all as specified and directed:-
Taking out sluice valve stuffing box and re-packing stuffing box of sluice valve of following sizes including taking apart & assembling & refixing it into its original position & replacement of rubber gasket and nut & bolts, complete all as specified and directed:-
80/100 mm dia
150/200 mm dia
250/300 mm bore
Supply and fix in repair CI sluice valves of following sizes having PN 1.6, conforming to IS -14846 Flanged end complete with iron wheel head and stainless steel spindle including flanged joints, replacement of perished nuts, bolts washers and rubber gasket etc, complete all as specified and directed:-
450/400 mm dia
300 mm dia
200 mm dia
150 mm dia
100 mm dia
80 mm dia
M&L for jointing flanged pipe and fittings including provn of rubber or fibre board gaskets and washers required for jointing including taking out fibre gaskets and nuts & bolts for the following sizes, complete all as specified and directed:-
80 mm Dia
100 mm dia
150mm bore
200mm bore
M&L cutting the road hard standing for laying of pipeline including filling& making good surface with PCC 1:3:6 C-1 Type using 20 mm graded stone aggregate & removing the debris to distance n.exe 50mtr, complete all as specified and directed.
Material and labour for taking down defective foot valves of following sizes from UG Sump, scraping the corroded footvalves and painting with one coat of red oxide along with black enamel paint, replacing rubber gaskets, bottom rubber with spring complete with replacement of necessary bolts, nuts, washers, complete all as specified and directed:-
150 / 200 mm dia
80 / 100 mm dia
Supply and fix in repair CI non return valve of 250/200mm dia size with by pass arrangement and necessary rubber gasket, nuts, bolts, and washers etc, complete all as specified and directed.
All as per Srl Item No. 35 of the above but size of 150 mm dia.
All as per Srl Item No. 35 of the above but size of 100 mm dia.
Supply and replacement of CI foot valve 250 mm bore, complete all as specified and directed by Engr-in-Charge.
All as per Sl. item No. 38 above but 200 mm bore.
All as per Sl. item No. 38 above but 150 mm bore.
All as per Sl. item No. 38 above but 100 mm bore.
All as per Sl. item No. 38 above but 80 mm bore.
Supply and fixing in repair cast iron air release valve with two air outlets, 80/100 mm dia bore with isolating sluice valve and fixing up in water supply mains including necessary addition / alternation to DI pipe 150/200/250 mm dia bore with all necessary fittings, complete all as specified and as directed.
Supply and replace Pressure gauge dial of 4" dia, 0-14 kgs/cm2 ratings suitable to the existing water pipe lines including suitable fixing lines with necessary fixing arrangement, complete all as specified and directed.
Supply and replace Electronic digital multifunction meter 415 V, 3 phase including CT, complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed.
S & F in repair of Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 ltrs hoisted and fixed in position incl dismantling of old water tanks, complete all as specified and directed.
All as per Srl Item No. 47 of the above but of capacity 1000 ltrs.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in conduit pipe of 20/25 mm size complete with PVC rectangular block with 3mm thick for mounting switch/ sockets regulators etc.and with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light/ fan point controlled by one switch including taking down of old wiring, complete all as specified and as directed by Engineer-in-Charge.
All as per Srl item No. 49 above but for 3 pin socket outlet point controlled by one, one way switch on the same board.
All as per Srl item No. 49 above but for one 3 pin switch socket combination of 5 Amp capacity on independent board.
All as per Srl item No. 49 above but for 3 pin switch socket combination of 15 Amp on independent board with cable 4 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano type 5 Amp single pole one way complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 2 in 1 , 3 pin 5 Amp flush type complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stepped type, electronic ceiling fan regulator complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminal complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way DB double door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
All as per Serial item No. 59 above but for 08 Way DB.
Supply and fix in repair 3 core 1.5sqmm PVC copper cable multi stranded drawn through inside pole from the bottom connector to fitting including providing necessary lugs complete incl taking down the existing wire, complete all as specified and directed.
Supply and fix of travel gear box assembly for SCADA operated of 250/300/400/450 dia sluice/ butter fly valve, complete all as specified and directed
Supply only DPF (Diesel Particulate Filter) oil, complete all as specified and directed.
Material & Labour for painting to old painted steel surfaces of Centrifugal/ monoblock Pump sets including painting of suction and delivery line inside and outside pump house uptp 6 mtr of following capacity with one coat of synthetic enamel paint including cleaning, scraping foreign material and degreasing surfaces, complete all as specified and directed:-
Up to 5 HP
M&L for disconnecting / removing the old unserviceable starters from the panel and supply and fix DOL/ starter Delta Starter for AC, 415V 50 Hz 3 phase suitable for following capacity of electric motor, complete all as specified and directed:-
Up to 5 HP
Supply and fixing in repair the MCCB of 630 Amps, 4 pole, breaking capacity 36 KA with continuously adjustable electronic release including taking down of the old unserviceable MCCB, complete all as specified and directed.
All as per Srl Item No. 66 of the above but 400 Amps, 4 pole, 36 KA.
All as per Srl Item No. 66 of the above but 200 Amps, 4 pole, 36 KA.
All as per Srl Item No. 66 of the above but 160 Amps, 4 pole, 36 KA.
All as per Srl Item No. 66 of the above but 125 Amps, 4 pole, 16 KA.
All as per Srl Item No. 66 of the above but 63 to 100 Amps, 4 pole, 16 KA.
Supply, fixing and testing of soft starter 415 Volts suitable for Pump of capacity 30 to 50 HP in existing LT panel with necessary fixing arrangements including taking down existing unserviceable one, complete all as specified and as directed by Engr-in-Charge
All as per Srl Item No. 72 of the above but of capacity 60 HP to 120 HP.
All as per Srl Item No. 72 of the above but of capacity 150 HP to 170 HP.
Supply and replace gland packing rope of 8/10/12/12.5/14/16mm sizes to pump sets of different sizes and capacities, complete all as specified and directed.
Supply and replace unserviceable brass air cock of suitable size to pump sets, complete all as specified and directed.
Servicing of soft starter 415 Volts suitable off size of different capacity installed at various location, dismantling the existing soft starter, servicing the same, replacing the defective spare parts and refixing it at the original place, complete all as specified and as directed by Engr-in-Charge
Supply and replace PVC cooling fan suitable for the existing motors of various capacity, complete all as specified and directed.
Supply and fix in repair Chlorination Plant gravity feed type of capacity 0-10 Kg/ hrs consisting of panel board with copper tube, primary filter, pressure releasing valve, connection pipe including all necessary connected items, complete all as specified and directed.
Supply and replace PVC Pipe of High Grade Flexible type of 20/25 mm for Chlorine gas outlet pipe, complete all as specified and directed.
M & L for preparation of steel surfaces of pipe of any dia (out side surfaces) and priming with red oxide primer and applying synthetic enamel paint with existing colour, complete all as specified and directed.
Supply and fixing in repairs digital water level indicator with ultrasonic sensor, display of P10 LED module (16X64 Red) aluminium frame encloser (wall mounted) with regulated power supply of 250V/5V with complete fixing arrangement like wiring, PCB and connectors to take reading upto 6 mtr on time from overhead/UG/Semi UG sump storage tanks as per IS and including cutting the RCC slab, and making good the slab, complete all as specified and directed.
Supply and fixing in repairs of carbon steel body electromagnetic flow meter of size 300 mm Dia/DN 300 complete with normal pressure 16 Bar, accuracy +/- 5% of reading, medium temperature -20 to 120 degree celcious, velocity 0.5 to 5 m/s, with internal digital LCD display (Flow rate and totalizer), output singnal 4-20mA lulse, communication RS485, IP65, liner material PTFE, measured tube electrode material SS304, SS316L and continousaly power supply to 230 volts, 50 Hz, complete all as specified and directed. Note :- The quoted rates shall deemed to be inclusive of cutting of existing pipe and putting of flanges, fittings if required, bolts and nuts, gasket complete.
Supply only chlorine gas in 100 Kgs cylinders to gravity feed gaseous chloronome plant, complete all as specified and directed. Note :- Testing the cylinder and repairs to outlet valve of cylinders shall be the responsibility of the contractors and cost for applying mineral jelly to parts etc, deemed to be included in the quoted rate.
Supply only CHLORINE 65%-70%(Calcium based granular disinfectant for water treatment more stable for water treatment than chlorine gas and stronger than bleaching powder and sodium hypochlorite) in 45 Kg drums, complete all as specified and as directed.
Supply only stable bleaching powder (SBP) (Calcium hypochlorite) Grade 1 , Availability Chlorine 34% Min, Stability 1/15 Max , Moisture 0.3% Max , Confirming to IS -1065, in 25 kg bag, complete all as specified and directed.
Supply, laying in trenches or fixing on wall or passing through pipe or in cable ducts, XLPE insulated PVC screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of 3.5 core 95 sqmm size including taking out old un-serviceable cable, complete all as specified and directed.
All as per Srl item no. 87 but for 3.5 core 120 Sq mm size complete.
All as per Srl item no. 87 but for 3.5 core 150 Sq mm soize complete
M&L for Synthetic mat (rubber matting) suitable for 11000 Volts electrical grade 2mx1mx19mm thick chequered top, ISI marked to be laid in front of LT panel board, complete all as specified and directed.
Supply and replace LED tube light fitting alongwith with fixture 22 Watts complete all as specified and directed.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
M& L for servicing of LT panels of any size by cleaning the panel, bus bar chamber with CTC solution, and welding the door using arc welding and fixing hinges, necessary nut and bolts, washers and made it completely functional for open/ close including painting of panel by spraying with two coats of epoxy based paint over a coat of red oxide primer, after cleaning of rusty panel surface both inside/ outside by emery paper and necessary preparation of smooth surface suitable for painting and including checking of incoming and outgoing connections, Re-fixing of existing ACBs & MCCBs, testing & commissioning, connected PCC & frame works, rewiring of control and power wiring with suitable size of FRLS copper cable but not less than 1.5 Sqmm, replacing of various unserviceable ON/ OFF switches, lugs etc making the panel fully functional, complete all as specified and as directed.
M&L for earthing complete incl necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip of size 32 x 6mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc., complete all as specified and directed. NOTE : (i) The conctrete pit shall be PCC 1:3:6 tye C -1 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protectio of earth wire. (iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pipt itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length earth lead wire.
M & L for cleaning of jungle/ vegetation by using excavator or manually for removing bushes / thick vegetation around the pump house, installations, levelling the area without damaging the pipelines / Cable network / Pedestals of pipelines / buildings including disposal of the vegetation / debris material up to a distance not exceeding 100 m of below mentioned area, complete all as specified and directed by Engineer-in-Charge.
Booster pump house 104 area old pump house approx 1000 sqm
Booster pump house 104 area new pump house approx 1200 sqm
Booster pump house Meghadripeta approx 2000 sqm
SCHEDULE OF CREDIT Note :- Amount of Rs. 1,83,545.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
GVR ENGINEERING WORKS (BID ID -3417473)
MSN ENGINEERING WORKS (BID ID -3418247)
SIVA MARUTHI ENTERPRISES (BID ID -3420908)
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3419107)
VENKATESWARA ENGINEERS AND CONTRACTORS (BID ID -3418326)
SVG SUPPLIES (BID ID -3418427)
M/S SRI VENKATA BHAVANI CONSTRUCTIONS (BID ID -3417609)
RATNA ENTERPRISES (BID ID -3417980)
Prasad and Suresh Constructions (BID ID -3418191)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .