Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.9 L+₹3.2 L (22.1%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L2 | Rejected-AOC Not Lowest |
Tender Value
₹19.3 L
EMD Value
₹38,600
Closing Date
18 Mar 2024, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE Hills Dehradun Mall road Dehradun Cantt-248003
COMPLETION OF INCOMPLETE WORK FOR SPECIAL REPAIR TO BLDG No 41 CIV MD ACCN AT 433 I SUP PL ASC AT LANSDOWNE
2024_MES_642334_1
87189/LDN/E8
Open Tender
Civil Works
Item Rate
150 days
AGE (I) LANSDOWNE
Class E Cat a i
6 documents required · 6 mandatory
₹500
Yes
AGE I LANSDOWNE
₹38,600
Yes
3 May 2024
14 Feb 2024
26 Mar 2024
14 Feb 2024
18 Mar 2024
29 Feb 2024
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickess including Nainital or similar pattern roofs covering including ridge, gutters, wind ties etc. complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, hips, valley, gutter, flashings etc and the like, fixed with self tapping screws as specified, complete all as specified and directed.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;complete all as specified and directed.
S&F for mild steel work as in bands, straps, hold fasts, clamps and similar small articles including cutting to shape as directed, drilling holes etc. conforming to Fe- 290.Gde-E-165 complete all as specified and directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed.
M&L for `E' board Classic ceiling, 4 mm thick with GI frame work of size main 'T' 24 x 28.5 mm made out of PGI sheet 0.30 mm thick doubled at web and single at flange, with powder coated sheet 0.25 mm thick and angles 24 x 24 x 0.3 mm covered with powder coated sheet 0.25 mm thick for ceiling boards 60 cm x 60 cm x 4.00 mm thick suspended with GI wire 2 mm dia & upto 2 mtr long with adjustable @ 1200mm c/c bothway complete incl plugging in brick walls with steel rawl plugs @ 600 c/c and applying two coats of distemper oil emulsion on ceiling board, complete all as specified and directed. (Note - Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides)
Dismantling boarding of any desciption, fixed in postion with nails complete all as specified and directed.
M&L 20 mm thick wooden boarding (2nd class hard wood) as in ceiling planed one side, with butt joints and fixed with nails including cutting out, piecing heading joints etc. matching the existing & polishing the same complete all as specified & directed.
Dismantling of timber scantling 40 Sqcm and above in section in any position, unframed work complete all as specified and directed.
M&L for second class hardwood as in scantling 40 Sqcm and above as in , clean sawn, timber unframed complete all as specified and directed.
Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with one coat of creosote oil complete all as specified and directed.
M&L raised pointing to random rubble or polygonal masonry masonry in Cement Mortar 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in cills, steps, parapets, bond stone, holdfast, coping, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work, complete all as specified and directed.
Taking down cement or cement plaster, any description onbrick wall or ceiling any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces in cement mortar 1:6 including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces in cement mortar 1:6 including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of cement base paint on new previously untreated plastered surfaces of walls including preparation of surface complete all as specified and directed.
M&L two coats of oil emulsion distempering on walls over a coat of primer after preparation of new plastered surfaces, complete all as specified and directed.
M&L applying three coats of white wash after preparation of new plastered surfaces of walls complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) exc. 1.50 Sqm and n. exc. 4.00 Sqm each complete all as specified and directed.
M&L for 2nd class hard wood (Sal) plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered put together with glue, pinned at joints, supplied and fixed, complete all as specified and directed.
M&L 35 mm thick Factory Made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, 2nd class HW rail and style, complete all as specified and directed.
M&L 35 mm thick Glazed and skeleton shutters, IInd class hard wood , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbersof shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M&L 30 mm thick Glazed and skeleton shutters, IInd class hard wood , open rebated and prepared to receive glass, gauze, etc.divided into squares, with plain, chamfered or rounded,mitred and rebated sash bars, any numbers ,any edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbersof shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed.
S&F 100 mm long mild steel cold rolled med weight butt hinges, fixed with MS screws, complete all as specified and directed.
S&F 75 mm long mild steel cold rolled med weight butt hinges, fixed with MS screws, complete all as specified and directed.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 100 mm aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 125 mm size aluminium handles, cast type, anodised, complete all as specified and directed.
S&F 100 mm size aluminium handles, cast type, anodised, complete all as specified and directed.
S&F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165. complete all as specified & directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F for 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane from wooden frames glazed with putty or fixed with beadscomplete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed
M & L for preparation of new or previously untreated wooden surfaces not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed
S& F in repairs 25 mm Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc Complete all as specified and directed
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern complete all as specified and directed.
S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action push type with inlet ball valve and float complete all as specified and directed
S&F PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers, complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 15 mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including cleaning for refixing and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
S&F 15 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
S&F 20 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
S&F in repair bib taps, brass, cast copper alloy CP with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair stop valves 15 mm nominal bore, cast copper alloy , fancy type, chromium plated , screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenchs complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bend 110 mm dia, any radius fitted with oval access door complete all as required and as directed.
S&F in repair PVC (SWR) vent cowl 110 mm bore, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bend 75 mm dia, any radius fitted with oval access door complete all as required and as directed.
S&F in repair 75 mm dia PVC (SWR) multi floor trap, with CP grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in soft/loose soil for foundation, etc. or for shafts, wells, cesspits, manholes, pierholes, etc. and getting out complete all as specified and directed.
Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated material (Soils) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed
M & L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
M&L for concrete bed in PCC 1:4:8 type D-2 ( using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
S&F in repair 150mm internal dia of pipe salt glazed stoneware drain pipes, laid in trenches and jointed in cement & sand mortar 1:1, complete all as specified and directed.
Demolition of cement concrete (reinforced) such as roofs, floors (other than ground floors), beams, stair cases, landing, chhajjas and other similar works and removing rubbish from premises, complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in landings, cover slabs (for manholes etc), chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary form work, set in CM 1:4, complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landing balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L for use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
M&L TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.11Sqm but not exceeding 0.18 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L for Glazed coloured ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and over and including 10 mm thick backiing coat of rendering of brick work or concrete surfaces in CM 1:4 complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floor and paving not exceeding 15 cm thickness below or above ground floors), complete all as specified and directed.
M&L PCC 1:3:6 type C-1 using 20 mm graded stone agg as plinth protection and floor, 75 mm thick , surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 mix, type B-2 (using 40mm graded stone agg) as in path/hard standing etc, finishing surfaces even and smooth without using extra cement and making impressions of expended metal whilst concrete is green, complete all as specified and directed.
M&L Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound,Grade ‘A’ for 75 /100 mm thick complete all as specified and directed.
M&L Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed.
M&L 60 mm thick rubber moulded Machine pressed cement concrete Interlocking coloured designer pavers block , M-35 grade any shape and size conforming to IS 15658-2006, manufactured by automatic compression with high compression stength any size, shape and pattern, with grey cement and pigment, laid in any pattern as approved over and including cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in path/sub base etc, laid in panels, finishing the surface even and rough to receive the top layer over 30mm thick (compacted thickness) sand cushion with joint filled with sand as approved complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channels and drains or benching of manholes including necessary formwork complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girths in cement concrete using extra cement incl forms, moulds, mitered/stopped ends etc, complete all as specified and directed.
Disconnecting existing water tank of capacity exc. 500 ltr but not exc. 1000 ltr, setting aside (or lowering of required) for repairs to roofs etc,cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and refixing in position on roof complete all as specified and directed.
Disconnecting water tank of capacity exc. 250 ltr but not exc. 500 ltr,and removing to store yard complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete with and including 20mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or for brass ferrule complete all as specified & directed.
M & L for point wiring with PVC insulated unsheathed (FR) stranded copper conductor of size 1.5 Sqmm (nominal cross sectional area) single core cable of 1100 volts grade in and including rigid non metallic PVC conduit 20 mm or higher size medium grade ISI marked complete with all PVC Conduit provided in concealed manner as directed at site including new pressed mild steel terminal sunken box made out of 1.2 mm thick sheet covered with & including new 3 mm thick plastic laminated hard glossy surface sheet top cover concealed in wall with brass screws & brass cup washers including continuous earth wire of green colour PVC insulated unsheathed 1100 volts grade single core cable, 1.50 Sqmm stranded copper conductor, connected to all fittings, sunk boxes, earth pointing sockets, connected to common earth, earth dolly complete all as specified & directed for the One light /fan /bell /exhaust fan point controlled by one, one way 5/6 switch or bell push one way 5/6 Amp.
All as per item No.83 above but One 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
All as per item No.83 above but One 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
M & L for point wiring with PVC insulated unsheathed (FRLS) stranded copper conductor of size 2.5 Sqmm (nominal cross sectional area) single core cable of 1100 volts grade in and including rigid non metallic PVC conduit 20 mm or higher size medium grade ISI marked complete with all PVC Conduit provided in concealed manner as directed at site including new pressed mild steel terminal sunken box made out of 1.2 mm thick sheet covered with & including new 3 mm thick plastic laminated hard glossy surface sheet top cover concealed in wall with brass screws & brass cup washers including continuous earth wire of green colour PVC insulated unsheathed 1100 volts grade single core cable, 1.5 Sqmm stranded copper conductor, connected to all fittings, sunk boxes, earth pointing sockets, connected to common earth, earth dolly complete all as specified & directed for One 6 Pin, 15/16 amps socket outlet point on independent board, controlled by one, one way 15/16 Amp switch.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S &F 5 pin socket outlet, 2 pin 5/6 Amps & 3 pin 5/6 Amps, flush type, ISI marked, complete all as specified and directed
S&F switch piano flush type 15/16 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
S &F 6 pin socket outlet, 3 pin 5/6 Amps & 3 pin 15/16 Amps,230 V flush type, ISI marked, complete all as specified and directed
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 20mm, 3 terminals, complete all as specified & directed.
S&F bell push flush type 5 Amps complete all as specified & directed.
S&F bell ding doll AC 230 volt single pole complete all as specified & directed.
S&F LED bulk head light fittings, with 9 watt LED bulb and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F batten lamp holder PVC/Polycarbonate type insulated with back plate suitable for PVC fittings with fixed on PVC block of 10x10x5 cm depth with LED bulb 9 watt complete all as specified & directed.
S&F MAXOLED BATTEN for T8 LED retetrofit Lamp (G13) Lamp holder Havells Cat Part NoLHFXCEP1TN1W020 of cap 20 watt including LED tube and 20 watt Havells Cat Part NoLHEXCEP7UN1W020 or equivalent in Phlips , Crompton Greaves and connected from ceiling rose /connector with and including suitable size flexible copper conductor PVC insulated sheathed cord, complete all as specified & directed.
S&F sheet metal enclosure for DB,single pole and neutral 8 way double door with 200 amps rated bus bar, 240 volts, suitable for housing MCB's and isolators, complete all as specified and directed.
S&F sheet metal enclosure for MCB DB, single pole and neutral 4 way double door with 200 amps rated bus bar, 240 volts, suitable for housing MCB's and isolators, complete all as specified and directed.
S&F AC single Phase static energy meter of accuracy class 1.00,240 volt ,50HZ with backlite LCD display of rating 5-30 Amps (measures and displays KWH , current 1, KW,pf, last month, history of KWH, MD in KW) with special features like TOD, temper logging , optical communication port display in abscence of power with transparent hinge type box complete all as specified and directed.
S&F MCB single pole 240 volt, 10 KA, 6 to 32 Amp, 'B' series conforming to IS 8828 of 1996 complete all as specified and directed.
S&F MCB single pole and neutral 240 volt, 10 KA, 32-63 Amp, 'C' series conforming to IS 8828 of 1996, complete all as specified and directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor cable of size 4.00 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia (Medium grade) PVC non metallic concealed conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 2.5 Sqmm single core multistranded copper conductor with sutable lungs made of copper cable green colour as earth continuity conductor. NOTE:- (i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. (ii) Cable required for connection to DBs shall deemed to be included and shall not be measured separately. (iii) Earth wire shall run inside the PVC conduit complete all as specified and directed.
S&F LED Street light 30W IP 65 including bracket made out of 25 mm dia light grade pipe of requird length not less than 1.20 mtr mounting bracket made out of mild steel FI 50x6 mm of required shape (two nos) duly fitted with mild steel nuts, 150 mm long, 12 mm dia bolts and washers and painting with two coats of synthetics enamelled paint over a one coat of red oxide Zink primer including connection wit 03 single core cable 23/.0076, PVC insulated copper conductor multistardad cable of required length complete all as specified & directed.
Supplying and fixing 1100 volts grade heavy duty cable of size 16 Sqmm standard aluminium conductor PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular complete all as specified & directed.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of the plate not less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 25x4mm GI strip welded and rivetted to earth plate at one end connected to main DBs of Bldg at another end GI earth strip encased in and including 32mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm dia GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 and precast RCC pit cover 50mm thick in RCC 1;2;4 type B-I duly reinforeced with MS bars 8mm dia @ 150 MM C/C with both wayswith lifting handle including excavation & earth work in any type of soil & removal of surplus soil upto 50 mtr complete all as shown in electrical plate no 5 of SSR part-I (2009) complete all as specified and as directed. Notes :- (1) Earth lead and GI pipe light grade 32 mm dia for protection against mechanical damage beyond 7.5 mtr from electrode to earth terminal point/main switch board etc shall be measured separately. (2) On testing, after completion of Job , if desired earth resistance is not obtained, the earthing shall be redone at no extra cost to Govt.
PIONEER REFRIGERATION AND ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .