Annual Comprehensive Maintenance contract CMC and Operation 24.7 for 33.11.440 KV HT Panel and Transformers existing at SLBSGMC and H Nerchowk in District Mandi HP
2026_PWD_141849_2
No.2026-3925-36 dated-13.08.2026
Open Tender
Electrical Works
Percentage
365 days
Nerchowk Distt- Mandi
As per SBD
14 documents required · 14 mandatory
₹2,000
₹66,630
19 Sept 2026
8 Sept 2026
14 Sept 2026
8 Sept 2026
13 Sept 2026
8 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Annual Comprehansive Maintenance Contract (CMC)&Operation 24/7 for 33/11/.440kv HT Panel and Transformer's existing at SLBS.Govt Medical Collage& Hospital Nerchowk in Distt. Mandi (HP) Make:-E Square Switchgears. | 1 | Per Job | 33,31,174 | ₹33,31,174 |
| 1.01 | SCOPE OF WORK | - | - | - | - |
| 1.02 | Round the clock operation routine maintence and troubleshooting if any fault occur of three number main Panel receiving 33/KV &11KV Indoor substation consisting of the following | - | - | - | - |
| 1.03 | Supervision of all function of Vacuum Circuit Breaker's and its IR Value | - | - | - | - |
| 1.04 | Providing lubricants and proper cleaning with blower on moveable parts time to time | - | - | - | - |
| 1.05 | Testing of relay through secondary injection | - | - | - | - |
| 1.06 | Tripping testing of Breaker through over current and earth fault relay | - | - | - | - |
| 1.07 | Daily Check control wiring, TNC Switch and indicator lamp annunciator panel,Master tripe relay,REJ 601 relay in all respect. | - | - | - | - |
| 1.08 | Testing of IR value of Breaker's | - | - | - | - |
| 1.09 | Setting/Programming of protection relay in/c relay co-ordination as per load and also checking of relay characterictics and operating time. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
SBD.pdf
Tender Documents • 3.19 MB
BOQ_212369.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .