Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.8 LAccepted-AOC 3RD CROSS 44 AND 97A ELECTRONIC CITY BENGALURU KARNATAKA INDIA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | ₹23.8 L | L-1 | Accepted-AOC Lowest Bid |
| 2 | L-2₹24.1 L+₹23,310 (0.98%)Rejected-Finance | ₹24.1 L+₹23,310 (0.98%) | L-2 | Rejected-Finance higher Bid |
| 3 | Not Admitted-PreQual/Technical 411 D JEEWAN PURAM BISHT DHARA BITHORIYA NO 1 HALDWANI HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | - | - | Not Admitted-PreQual/Technical Others-Not meet TQR |
| Sl No | Description | Qty | Unit | Infosys Technologies L1 | Manvi Traders L2 |
|---|---|---|---|---|---|
| 1.00 | Providing, fixing and installation of Linear Heat Detection System for cable trenches in 220 kV switchyard at 400 kV Substation Rishikesh; UL listedwith fixed alarm temperature and trigger the alarm single at factory set temperature of 70/ 90 deg as per, 35mtrs one zone will be install complete in all respect.area of all trenchs in switchyard including switchyard to control room.
• The Digital LHDC construction should be suitable for use in a harsh environment.
• The Digital LHDC shall comprise of a twin core cable twisted under tension. and have a special heat reactive .polymer insulation.
• The Digital LHDC shall have an overall protective sheath which is resistant to Hydrocarbons, Chemicals, and be UV resistant.
• The Digital LHDC shall have a maximum conductor resistance of 100Ω/km (at 20°C).
• Final installation shall ensure that the Digital LHDC is not in contact with any heat sink material which may delay the sensing process.
• The Digital LHDC shall be terminated with manufacturers’ Industrial grade junction boxes.
• The Digital LHDC shall have a fixed alarm temperature of 70/90 deg or and be capable of installation where intrinsically safe configurations in hazardous areas are required.
• The Digital LHDC shall be UL approval and be Certified.Alarm : Technical Specifications:
Temperature: 700-070 = 70°C 700-090 = 90°C 700-180 = 180°C Max Ambient Temperature: 700-070 = 45°C
700-090 = 70°C 700-180 = 150°C Min Operating Temperature: -65°C Min Installation Temp: -40°C Outer Sheath: Nylon (70°C & 90°C - Black)* Hytrel (180°C - Violet)* Stainless Steel Armour Option* UV & Chemical Resistant
Voltage Rating: 150Vdc (Dielectric Test 500Vdc) Outer Diameter: (Maximum) 4.0mm ± 0.3mm Stainless Steel Armour 4.5 ± 0.3m | 950 | mtrs | 934 ₹8,87,300 Lowest | 950 ₹9,02,500 |
| 2.00 | Providing, fixing and installation of LHDC Controller Logic module Panel DXc1/4007ES or compatible addressable fire alarm Control panel LPCB approved support up to 1-5 loop intelligent single loop addressable panel 6#40 characters ,blue liquid crystal display panel inbuilt sound 105 db operational environment 2 degree centigrate to 80 degree configuration by keyoad and PC the panel is compatible with add on feature. as per site requirment/instruction of site engineer complete in all respect.
• Expandable Logic module 230 VAC input,
• Data logging
• AC 230 V
• Relay, max. 10 A,
• Maximum configuration 24DI/20DO/8AI/8AO,
• Power supply AC/DC 115/230V, incl. clock,
• Noise emission limit class B group 1,
• Ambient temperature 0 to 55°C | 2 | Nos | 1,63,500 ₹3,27,000 Lowest | 1,67,400 ₹3,34,800 |
| 3.00 | Providing, fixing and installation of Manual Call Point to report the fire in case of Digital LHDC fire incident is visually reported. | 6 | Nos | 17,340 ₹1,04,040 | 15,000 ₹90,000 Lowest |
| 4.00 | Providing, fixing and installation of Flameproof Outdoor Hooters cum Strobe to trigger the alarm in case of Digital LHDC fire incident including T&P and all. | 5 | Nos | 11,950 ₹59,750 | 11,500 ₹57,500 Lowest |
| 5.00 | Providing, fixing and installation of Monitor module with termination 4090-9001 for zone control and required to operate the LHS. | 14 | Nos | 35,000 ₹4,90,000 Lowest | 36,500 ₹5,11,000 |
| 6.00 | Back box with accessories with EOL Register, glander, termination block, wheatherproof junction box, Pvc pipe, support wire as per site requirment including T&P and all. | 2 | Job | 46,750 ₹93,500 | 43,500 ₹87,000 Lowest |
| 7.00 | FDA System Programming Commissioning and Gateway Programming with testing and handover for LHS only | 2 | Job | 1,14,200 ₹2,28,400 Lowest | 1,19,000 ₹2,38,000 |
| 8.00 | Providing, laying and connections of 2 core, 1.5 Sqmm, FRLS, Armored signal cable for LHS interfacing with FDA loop as per site requirment. | 2 | Job | 35,000 ₹70,000 | 32,000 ₹64,000 Lowest |
| 9.00 | Miscellaneous work like Power point arrgement ,laying of power cable at different locations including other electrical work as per requirment, Power arragemaent of all panels open and close the trench of switchyard, civil work if required, fabrication work if any for cable hanging and clearing of grass, bushes in trench as per required for strengthing of LHS system as per instruction of site engineer. | 3 | Job | 41,500 ₹1,24,500 | 41,000 ₹1,23,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
13 Jan 2025, 3:00 pmClosed
Chief Engineer O and M Garhwal Zone Roorkee
Chief Engineer O and M Garhwal Zone PTCUL 26 Civil lines Roorkee
Strengthening of safety system of power cables in trenches and associated work with digital liner heat detection cable system LHDC in 220 kV Switch yard at 400 kV Substation, Rishikesh
2024_PTCUX_78755_1
CE/GZR-17/2024-25
Open Tender
Electrical Works
Item Wise
90 days
Rishikesh
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,360
SE Oand M Transmission Circle Roorkee
₹85,000
30 Jun 2026
13 Dec 2024
14 Jan 2025
13 Dec 2024
13 Jan 2025
13 Dec 2024
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .