Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.2 L
EMD Value
₹2,300
Closing Date
13 Nov 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Construction /Remodelling of Washroom /Toilet Blocks for Judiciary/Court Complexes Kashmir Division (Munsif Court Beerwah) B.W.O Internal electrification
2025_PWDJK_292977_1
NIT No.157/2025-26 Dt/23/10/2025
Open Tender
Electrical Works
Percentage
Beerwah
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹2,300
23 Oct 2025
23 Oct 2025
14 Nov 2025
23 Oct 2025
13 Nov 2025
24 Oct 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex /Havells /Salzar/Anchor /Rhein make in recessed medium class PVC conduit (Including cutting of walls and refacing of same ) , with 6Amps modular switch, modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand /Havels make , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for lightl power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit (Including cutting of walls and refacing of same ) alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab /Finolex /Anchor /havells/Salzar /Rhein make.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recessed medium class PVC conduit (Including cutting of walls and refacing of same ) as required. of Polycab / Finolex /Anchor / havells/Salzar /Rhein make.
2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire
2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Schneider /ABB /L&T /Legrand /Simens make )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 6 Amp modular socket outlet and 6 Amp modular switch, connections etc. as required. ( Schneider /ABB /L&T /Legrand /Simens make )
Supply, Installation testing and commissioning of 200mm- 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's /Orient /Helonix make incl making of necessary connections and making of necessary space in walls / Windows as per site.The Job includes providing and fixing of Hylum sheet of required Size for exhaust fan. The job further encompasses providing and fixing 3-way ceiling rose.
Supply ,installation ,Testing and Commissioning of 10-12 Watts ,2 ft long LED tube light fitting having PVC Body (Commercial type) of standard make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job.The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit initial system lumen output of 1400 lumens with minimum system efficacy of 120 lumen/watt. The luminaire shall comply to lifetime of 50000Hrs @ L70B50 with design ambient temp 45°C. The electronic driver used shall have a power factor ≥0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, THD≤10%, Current Ripple ≤5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I. The luminaire should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions of the batten shall be 44mm X 51mm X 1157mm. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Approved make Helonix /Wipro / Bajaj / Crompton make (to be approved before installation)
Supply and fixing of 12-15 Watts LED surface /recess (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminium. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. Approved make Helonix /Wipro / Bajaj / Crompton or any other make as approved by department (to be approved before installation)
Supply ,Installation ,Testing and Commissioning of IP66 , 45-50 Watt LED Flood light Luminaries having Aluminium body of of standard make dully isi marked ,to be fitted on walls / poles with necessary cliffs /Clamps with nuts and bolts complete job.The system efficacy of the luminaire shall be ≥120lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire. The maximum dimensions of the luminaire shall be, L: 264M, Depth: 52MM & height without cradle: 203MM. The nominal weight of the luminaire shall be maximum 2.4KGs. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Approved make Helonix /Wipro / Bajaj / Crompton or any other make as approved by department (to be approved before installation)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) of Legrend /L&T /ABB /Simens /Schinder make
16 way, Double door
Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make
Supply,Laying,Testing & Commissioning of 10 sq.mm 2- core -armored Al Cable XLPE/ PVC Insulated and of Havells/paramount /KEI make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections. The cable is to be laid partially under ground including execuation and refilling back after cable laying and partially above ground including clipps etc.
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required including 8 No G.I wire from earthing electrode to controlling unit through PVC Conduit in One run.The job includes providing and fixing of main hole PVC Chamber with its cover complete job
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.08 MB
BOQ_945989.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .