RequiredExperience with Government
RequiredOEM Authorization Certificate Bid to RA enabled No Product Maintenance Service For EPABX ( 6 ) Technical Specifications Specification Values Type of Service Comprehensive Vintage 4-7 Years Product Type Similar Specification Specification Name Value EXTENSION AND TRUNK JUNCTION EPABX system Implementation Technology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Number of Analogue Extensions FXS Ports 192 Expandable Upto (TDM/FSX Ports) 1296 Number of Digital Extensions 32 1/8 Number of Analogue Junction/FXO ports 16 Number of SIP Extensions NA SIP Extensions expandable upto 512 Number of SIP Trunks NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 600 Integrated Protection Module(IPM) No If YES
Requirednumber of Integrated Protection Module(IPMs) NA CARDS CARDS Type of Cards Supported BRI
RequiredPRI
RequiredE1
RequiredE&M
RequiredRadio Interface
RequiredGSM
RequiredNA Number of Ports per Card Supported NA GATEWAYS Type of Gateways Supported Universal Gateway
RequiredSIP
RequiredFXO
RequiredFXS
RequiredPRI Number of Ports per Gateway Supported 1 CONSOLE Type of Operator Console Key phone based Number of Operator Console 1 SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA "Number of Hot Standby Servers out of Total Servers
Requiredincluded in the Scope of Supply" 0 Server Form Factor NA Rack Size (RU)/Space Required for each Server NA Processor Make NA Processor Configuration & Description QORIQ P1015 533MHz 1332.5 DMIPS
RequiredPCB/GLOBAL DATA BUS (RD1
RequiredRD2
RequiredWR3 ACCESS PARALLEL MOVEMENT 14.2 GBps) SYSTEM BUS 266MHz 128 BITS 5.7GBps Total Number of processor NA Number of Redundant Processors Included in the Total Number of Processor NA Number of Cores per Processor NA Type of RAM NA RAM Size (in GB) NA T ype of Hard Disk Drive NA 2/8 Capacity of Hard Disk Drive (in TB) NA Hot Swap Components NA Network Interface NA SOFTWARES Applcation Software Type Capabilities Call Server Software Type of Licence Perpetual Name of Softwares Call Server Software Name of the OEM NEC OEM Model/Part Number SV 9100 Software Description Voice Mail 10
RequiredSoftware Version r8 Date of Launch of Version 15.02.2018 Free supports/updates during validity of license NA SOFTWARE FEATURES Analog Extention/FXS ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK JUNCTION"" ) YES "Digital Extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES "Analog Junction/FXO ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES "SIP extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NO "SIP trunk ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO 3/8 "PRI Trunk ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES "Radio Interface ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO "GSM ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO "E1 Trunk ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO "E&M ( If Yes
RequiredNumber of Software/Licences shall be Commensurate/Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 32 Number of Direct Station Selection Keys per Console 24 Number of Media Channel/Ports Supported 256 Number of IP-TDM Concurrent Calls(2 users per call) Supported 256 Call Buffer Memory System Yes If Call Buffer Memory Available
RequiredNumber of Records 2000 Hot Standby Redundant CPU No If YES
RequiredNumber of Hot Standby CPU Cards NA Hot Standby Redundant PSU (Power Supply Unit) No If YES
RequiredNumber of Hot Standby Redundant PSU Cards NA 4/8 Inbuilt Voice Mail for EPABX System Yes If Voice Mail Available
RequiredNumber of Voice Mail Channels 8 Available for Voice Mail
RequiredNumber of Hours of Recording 8 Auto Attendant Facility Yes If Available
RequiredNumber of Auto Attendant Channels 4 ASMDR/CDR Yes Voice Logger NA If YES
RequiredNumber of Simultaneous Calls that can be Recorded in Voice Logger NA Security Feature(for server based) NA Supported Functionalities (for server based) NA Supported Codecs G711
RequiredG729
RequiredG723 Any other features pc console SYSTEM/EXTENSION/ATTENDAN T CONSOLE FEATURES System Features Automatic Route Selection facility
RequiredDID facility(Direct inward dialing)
RequiredDOD facility(Direct outward dialing)
RequiredDISA facility(Direct inward station access)
RequiredDOSA facility(Direct outwards station access)
RequiredMulti Level Voice DISA facility
RequiredPrivacy of Call
RequiredFacility for connecting recorded voice a nswering
RequiredASMDR/CDR
RequiredProgram mable class of service for (STD/ISD/LOCAL) dialing as per need
RequiredCaller ID information for both internal and external callers (over Analogue
RequiredISDN PRI)
Requiredunique authorization codes for every users
RequiredAutomatic call back
RequiredCall waiting
RequiredMusic-on-hold facility
RequiredCall budgeting
RequiredLeast cost routing
RequiredMix-mode dialing
RequiredProvision for remote logins
RequiredInteractive Voice Response System(IVRS)
RequiredExtension to Extension dialing Extension Features Call forwarding
RequiredConsultation Hold
RequiredBrokers Call
RequiredAutomatic call transfer
RequiredConference call
RequiredCall pick up
RequiredCall re routing
RequiredAuto call 5/8 disconnection
RequiredDynamic STD Lock
RequiredPaging on key phone
RequiredBackground music
RequiredPassword control
RequiredVirtual Telephony
RequiredHowler Tone
RequiredCall parking
RequiredAuto answer/Auto off
RequiredEmergency call facility
RequiredMissed/Dialed/Received Call Lists
RequiredLast Caller Call back
RequiredPassword display suppression
RequiredPersonal Identification Number
RequiredHotline
RequiredPreset Conference Calls
RequiredDirect Call billing in rupees
RequiredCall billing printout
RequiredCalling line identification(CLI)
RequiredRemote Maintenance
RequiredOther Extension features Attendant Console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Voice Prompts and Announcement Yes If yes
RequiredNumber of Levels of IVRS 4 POWER SOURCE Supply Voltage 230V AC
Required50HZ Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup NA FCBC NO If YES
Requiredminimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA Protection against over current and accidental reversal of polarity on the input side and against over current
Requiredover voltage on the output side NA OPERATING CONDITIONS Minimum Operating Temperature (Degree C) -10 Maximum Operating Temperature (Degree C) 45 Operating Humidity (RH) (% ) 90 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES TEC approval Certificate TEC/NR/I/PBX-04/02/103.SEP 15 6/8 number Availability of the test report from Central Government NABL/ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence Yes Test Report Number and date (not a part of biddable parameter) ENV/G.0166/0476/2018 DATED 31.03.2018 Name and Address of the Test lab(not a part of biddable parameter) ELECTRONICS AND QUALITY DEVELOPMENT CENTRE
RequiredGANDHINAGAR
RequiredGUJRAT Test reports consist of verification of all the features & functional parameters & environmental tests Yes conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/section-5/1977 latest Yes conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/section-4/1977 latest Yes conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/section-1/1991 latest Yes INSTALLATION AND MAINTENANCE Installation and Commissioning With Chemical Earthing to achieve resistance No Recommendation/Information regarding Supporting Hardware Required to meet the Performance/Capabilities of the System with OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES Operation & Maintenance terminal Provided 7/8 Training provided to buyers Yes If YES
RequiredDetails of training On site training for 3 days Packing List yes SERVICES Warranty 1 Recommendation/Information regarding Supporting Hardware Required to meet the Performance/Capabilities of the System
Required1 year Compliance to STC of the Product Yes