Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance | ₹9.9 L | L1 | Accepted-Finance Accepted L-1 |
| 2 | L2₹9.9 LRejected-Finance BHANIYAWALA 248140 DISTRICT DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | ₹9.9 L | L2 | Rejected-Finance Accepted L-1 |
| 3 | L3₹9.9 LRejected-Finance 288 RANIPUR MORE HARIDWAR 249401 | HARIDWAR | UTTARAKHAND | 249401 | ₹9.9 L | L3 | Rejected-Finance Accepted L-1 |
| Sl No | Description | Qty | Unit | United Engineers L3 | NANO TECHNOLOGY L1 | LIV TECHNOLOGY L2 |
|---|---|---|---|---|---|---|
| 1.00 | Rectification of wiring of 220 KV earth switch / isolator / circuit breaker (all R, Y, B phase) to make it electrically operated. Following work is to be carried out-
a) Check the old wiring and change the damage old / damaged wiring as per connection diagram.
b) Checking the all contactor & connector and replacement of faulty contactor & connector with new one.
c) Checking of the motor of earth switch / isolator / circuit breaker and rewinding of the winding of burn motor.
d) Enable the all indication of C&R panel i.e. open / close / spring charge / semaphore etc. and replacement of defective indication if required.
e) Testing of successfully operation of 220 KV earth switch / isolator / circuit breaker by local / remote. | 22 | Job. | 44,950 ₹9.9 L | 44,800 ₹9.9 L | 44,900 ₹9.9 L |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
6 Jan 2026, 1:00 pmClosed
Superintending Engineer
SE, O and M Circle, PTCUL ,26-Civil Lines, Roorkee.
Work of rectification of electrical wiring and removed the fault of control wiring for electrically operation of 220 KV bay equipments at 220 KV Substation SIDCUL Haridwar.
2025_PTCUX_89620_1
T-30/SE(OandM)CR/2025-26
Open Tender
Electrical Works
60 days
SIDCUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
SE O and M PTCUL Roorkee
₹30,000
Yes
5 Jun 2026
6 Dec 2025
7 Jan 2026
7 Dec 2025
6 Jan 2026
7 Dec 2025
Rectification of wiring of 220 KV earth switch / isolator / circuit breaker (all R, Y, B phase) to make it electrically operated. Following work is to be carried out- a) Check the old wiring and change the damage old / damaged wiring as per connection diagram. b) Checking the all contactor & connector and replacement of faulty contactor & connector with new one. c) Checking of the motor of earth switch / isolator / circuit breaker and rewinding of the winding of burn motor. d) Enable the all indication of C&R panel i.e. open / close / spring charge / semaphore etc. and replacement of defective indication if required. e) Testing of successfully operation of 220 KV earth switch / isolator / circuit breaker by local / remote.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
T30DOC.pdf
Tender Documents • 1.09 MB
BOQ_106258.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid