Executive Engineer,Sauni Yojana Division,Rajkot
Engineering, procurement and construction (EPC) contract Supply Water from Machhu -1 Dam to Triveni Thanga Reservoir and Various Villages of Wankaner and Chotila Taluka, with Operation and Maintenance of the commissioned project for 10 Years
273080
2025-2026
Open
Miscellaneous Works
Works
Rajkot
36 documents required · 36 mandatory
₹18,000
Yes
Executive Engineer, Sauni Yojana Division, Rajkot
₹1.8 Cr
Yes
5 Feb 2026
5 Feb 2026
5 Feb 2026
6 Mar 2026
5 Feb 2026
Designing and Constructing Boundary wall for H.W. Compound Wall at MPS, IPS-1 and IPS-2 as per drawing.
Designing and Constructing Main gate and wicket gate with RCC supporting column and cattle trapat at MPS, IPS-1 and IPS-2 as per drawing.
Designing and Constructing RCC Internal Road at Pumping station as per drawingat MPS, IPS-1 and IPS-2 as per drawing.
Designing and Constructing Storm water drain at MPS, IPS-1 and IPS-2 as per drawing.
Designing and Constructing Security cabin of Internal size 3.0 M X 3.0 M with all allied works as per drawing at 1 Nos- MPS+1 Nos- IPS-1 + 1 Nos IPS-2 + 11 Nos for Flow Meter at 10 MIS and 1 Dam (TT)
Designing and Constructing Staff quarter in RCC frame structure at PS Twin dweling unit as per drawing at Head works With required water supply , Sanitary arrangement etc. completed. at MPS, IPS-1 and IPS-2
Designing and Constructing Store room of 10m x 6m in RCC frame structure at PS as per drawing at MPS, IPS-1 and IPS-2 Head works with electrification etc. complete as per drawing.
Site development and Site grading, Gardening, Beautification, Planting ,Water Supply arrangement Tube Well with necessary civil with electrical work and Lighting with decorative pole in plot of MPS, IPS-1 and IPS-2 .
Designing (Aesthetically) and constructing R.C.C. frame Structure of MCC Room of Internal size 20mX12m at MPS and IPS-1 with PLC/ SCADA Room, Battery Charger Room, Office Room and Toilet Facility with all allied works as per Drawing.
Designing (Aesthetically) and constructing R.C.C. frame Structure of MCC Room of Internal size 15mX12m at IPS-2 with PLC/ SCADA Room, Battery Charger Room, Office Room and Toilet Facility with all allied works as per Drawing.
Designing (Aesthetically) and constructing R.C.C. frame Structure of HT pannel Room at 5mt X 5mt IPS-2 with all allied works as per drawing
Designing and Constructing R.C.C. Under Ground Sump of minimum 5000 m3 capacity with inlet and overflow arrangement with required suction pit , Staircase, Water level Indicator, Trash Rack and GI Railing on periphery of sump etc. and rate also include construction of RCC Framed Structure Pumping Station Partially on Under Ground Sump of minimum size as per ploat with minimum height of 10 M from Plinth Level to celing of bottom slab. The rate also Include Providing Fixing Rolling Shutter, Door, Window, Vantilator, Internal and Outside Plaster, Flooring, Ramp with P.V.C. water tank and allied works as per Drawing. at MPS and IPS-1
Designing and Constructing R.C.C. Under Ground Sump of minimum 1100 m3 capacity with inlet and overflow arrangement with required suction pit , MS ladder, Water level Indicator, Trash Rack and GI Railing on periphery of sump etc. and rate also include construction of RCC Framed Structure Pumping Station Partially on Under Ground Sump of minimum size as per ploat with minimum height of 10 M from Plinth Level to celing of bottom slab. The rate also Include Providing Fixing Rolling Shutter, Door, Window, Vantilator, Internal and Outside Plaster, Flooring, Ramp with P.V.C. water tank and allied works as per Drawing. at IPS-2
Making Connection in existing Sump to Proposed Sump at MPS Inlcuding flow control gate with Support Structures, canal and other civil, electro-mechnaical equipments at MPS as per Site condition and Detail Drawings
Designing (Aesthetically) and constructing R.C.C. frame Structure of Upto 3.6 Mt height (Floor to Ceiling Level) for Fire fighting room 5mt x 5mt at MPS and IPS-1
Design and analysis of surge system comprising of Zero velocity valve, Air cushion valve and Stand pipe including construction of valve chambers in pipe network for surge pressures (i.e. positive and negative) for 50percentage closure of Air Valve with working scenarios within permissible conditions as per specifications and standards including vetting by IISC/IIT, supply, installation along with all accessories/equipment and civil support/ Enclosures. etc. Complete. For Pipe Line network.
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standing crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. From Existing pipe of L3P4 to Prposed sump at H.W. 610 mm dia MS Pipe (OD) - 6.3 mm thick
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standing crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. From Existing pipe of L3P4 to Prposed sump at H.W. 914 mm dia MS Pipe (OD) - 8.0 mm thick)
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standing crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. From Existing pipe of L3P4 to Prposed sump at H.W. 1219 mm dia. (OD) - 10.00 mm thick MS Pipe
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standard crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. 323.9 mm dia MS Pipe (OD) - 5.6 mm thick For For scoure Valve / Sluice Valve / B-F Valve
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standard crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. 406.4 mm dia MS Pipe (OD) - 6.3 mm thick For scoure Valve / Sluice Valve / B-F Valve
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standard crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. 610 mm dia MS Pipe (OD) - 6.3 mm thick For scoure Valve / Sluice Valve / B-F Valve
Manufacture, supply and delivery of submerged Arc welded M.S Pipe having bevelled ends from plate or coil conforming to IS-3589-2001 or its latest revision / amendment with inside 406 micron thick food grade epoxy painting and outside 3LPE coating for following thickness and outside diameter at site with all type of specials, tees, bends and flanges, lowering, laying and jointing the pipes with welding in prepared trench with required excavation in all strata’s, breaking the road surfaces andreinstating the same, including crossing, all existing underground/ above ground utilities such as gas ,oil water, cable structure etc. as per requirement, joint coating with HSS, proper murum bedding in required thickness, refilling the trenches after completion of work including providing and fixing pipe indicators at every 1 Km distance including field hydraulic testing etc. complete with all taxes, insurance, freight charges, inspection charges, transportation, etc. complete. The work also includes payment of Standard crop compensation, other damage compensation etc., co ordination Liaisoning and getting ROU / ROW permissions for laying of pipe line as per alignment. Statutory charges for permission, miscellaneous charges, etc. are to be paid by the contractor. 813 mm dia MS Pipe (OD) - 7.1 mm thick For scoure Valve / Sluice Valve/ B-F Valve
Providing and supplying conforming to ISI Ductile Iron D.F. Sluice Valves including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to departmental stores, stacking, etc. complete including lowering, laying and jointing in position including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. PN-1.0 with hand wheel/ cap operated (PD type short body) 300 mm dia. SV PN 1.0 with RCC(M20) chamber of minimum size 1.5Mx1.5M with required depth, including payment for crop compansation ROU Cost .
Providing and supplying conforming to ISI Ductile Iron D.F. Sluice Valves including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to departmental stores, stacking, etc. complete including lowering, laying and jointing in position including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. PN-1.0 with hand wheel/ cap operated (PD type short body) 400 mm dia. SV PN 1.0 with RCC(M20) chamber of minimum size 1.5Mx1.5M with required depth, including payment for crop compansation ROU Cost .
Providing and supplying conforming to ISI Ductile Iron D.F. Sluice Valves including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to departmental stores, stacking, etc. complete including lowering, laying and jointing in position including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. PN-1.0 with hand wheel/ cap operated (PD type short body) 600 mm dia. SV PN 1.0 with RCC(M20) chamber of minimum size 1.5Mx1.5M with required depth, including payment for crop compansation ROU Cost .
Providing and supplying conforming to ISI Ductile Iron D.F. Sluice Valves including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to departmental stores, stacking, etc. complete including lowering, laying and jointing in position including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. PN-1.0 with hand wheel/ cap operated (PD type short body) 600 mm dia. SV PN 1.6 with RCC(M20) chamber of minimum size 1.5Mx1.5M with required depth, including payment for crop compansation ROU Cost .
Providing and supplying conforming to ISI Ductile Iron D.F. Sluice Valves including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to departmental stores, stacking, etc. complete including lowering, laying and jointing in position including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. PN-1.0 with hand wheel/ cap operated (PD type short body) 800 mm dia. SV PN 1.0 with RCC(M20) chamber of minimum size 2 Mx 2 M with required depth, including payment for crop compansation ROU Cost .
Providing and supplying conforming to ISI Ductile Iron D.F. Sluice Valves including all taxes, insurance, transportation, freight charges, inspection charges, loading, unloading, conveyance to departmental stores, stacking, etc. complete including lowering, laying and jointing in position including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. PN-1.0 with hand wheel/ cap operated (PD type short body) 800 mm dia. SV PN 1.6 with RCC(M20) chamber of minimum size 2 Mx 2 M with required depth, including payment for crop compansation ROU Cost .
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 300 mm dia DI BF valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 1.5MX1.5M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 400 mm dia DI BF valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 1.5MX1.5M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 600 mm dia DI BF valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 1.5MX1.5M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 800 mm dia DI BF valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 2 MX 2 M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 800 mm dia DI BF valve of PN 1.6 with expansion bellow and Constructing RCC chamber of minimum size 2 MX 2 M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 300 mm dia DI PRV valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 1.5MX1.5M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 600 mm dia DI PRV valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 1.5MX1.5M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting ISI mark Ductile Iron Butterfly valves as Isolation Valves with expansion bellow, jointing to pipe work (including all hardware and packing) water quality, having non-rising spindle with hand wheel, etc. as per requirement, including C.C foundation / structural steel support with suitable dia. valve as per design requirement for bypass 150 mm dia arrangement including designing and constructing RCC (M20) Chambers. 900 mm dia DI PRV valve of PN 1.0 with expansion bellow and Constructing RCC chamber of minimum size 2 MX 2 M with required depth including payment for crop compansation ROU Cost And bypass arrangement of 150 mm dia.
Providing and erecting 80 mm dia DI Temper proof Air valve (as per AWWA C 512) with Air Valves having with SS 304 Float gun metal- nozzle isolating Sluice Valve mounted on shaft in position operated by wheel gear suitable for working pressure of 10 kg/cm² (PN -1.0) including Providing and fixing M.S. Pad over main pipe line with providing and fixing Air Valve shaft of min 5.0 M height, with encasing of shaft in RCC M20 and thrust block at HDPE Pipe and shaft Connection 80 mm dia. GI Heavy Duty Pipe, tamper proof Air Valve (PN1.0) with Isolating sluice valve PN-1.0
Providing and erecting 80 mm dia DI Temper proof Air valve (as per AWWA C 512) with Air Valves having with SS 304 Float gun metal- nozzle isolating Sluice Valve mounted on shaft in position operated by wheel gear suitable for working pressure of 10 kg/cm² (PN -1.0) including Providing and fixing M.S. Pad over main pipe line with providing and fixing Air Valve shaft of min 5.0 M height, with encasing of shaft in RCC M20. for M.S Pipe Connection 80 mm dia. GI Heavy Duty Pipe, tamper proof Air Valve (PN1.0) with Isolating sluice valve PN-1.0
Providing and erecting 150 mm dia DI Temper proof Air valve (as per AWWA C 512) with Air Valves having with SS 304 Float gun metal- nozzle isolating Sluice Valve mounted on shaft in position operated by wheel gear suitable for working pressure of 10 kg/cm² (PN -1.0) including Providing and fixing M.S. Pad over main pipe line with providing and fixing Air Valve shaft of min 5.0 M height, with encasing of shaft in RCC M20. for M.S Pipe Connection 150 mm dia. GI Heavy Duty Pipe, tamper proof Air Valve (PN1.0) with Isolating sluice valve PN-1.0
Providing and erecting 150 mm dia DI Temper proof Air valve (as per AWWA C 512) with Air Valves having with SS 304 Float gun metal- nozzle isolating Sluice Valve mounted on shaft in position operated by wheel gear suitable for working pressure of 10 kg/cm² (PN -1.0) including Providing and fixing M.S. Pad over main pipe line with providing and fixing Air Valve shaft of min 5.0 M height, with encasing of shaft in RCC M20. for M.S Pipe Connection 150 mm dia. GI Heavy Duty Pipe, tamper proof Air Valve (PN1.0) with Isolating sluice valve PN-1.6
Designing and constructing R.C.C. Thrust Block with Controlled cement concrete using cement, sand and crushed aggregate by mass and machine mix for R.C.C/CC work including necessary formworks centering scaffolding compaction by mechanical vibrator,curing as directed with all lead and lift etc complete Including the cost of reinforcement. For Friction block Concrete grade M-20 and MSA - 20 mm
Designing and Constructing encasing over pipe with Controlled cement concrete using cement, sand and crushed aggregate by mass and machine mix for R.C.C. / C.C. work including neccesary formworks centring scaffolding compaction by vibrator, curing as directed with all lead and lift etc complete Including the cost of reinforcement(For Plinth Course and Coping) Concrete work for Encasing Drains and River. Concrete grade M-20 and MSA - 20 mm
Providing and fixing MS inspection manhole / chamber of 600mm dia as per drawing as directed
Drilling of Horizontal bore hole for water main pipeline under the Railway/ Road tracks in all strata with required length includes the cost of drilling of bore hole, Casing pie and welding pushing etc complete but excluding the cost of water main, valves and other items, entire work should be as per approved drawing and as per instruction of Railway/Road authority for following diameter of bore hole for MS pipe and The Rate Include Preparation of Plan, Design , Drawing and Getting Permission from concern department including all required payment to concern department including getting N.O.C. after completion of work from concern authority. For National Highway Crossing and State Highway Crossing.Horizontal Drilling-1800 :and MS Casing Pipe-1626 thick:14.2 mm thick for 1219 Dia M.S carrying pipe
Drilling of Horizontal bore hole for water main pipeline under the Railway/ Road tracks in all strata with required length includes the cost of drilling of bore hole, Casing pie and welding pushing etc complete but excluding the cost of water main, valves and other items, entire work should be as per approved drawing and as per instruction of Railway/Road authority for following diameter of bore hole for MS pipe and The Rate Include Preparation of Plan, Design , Drawing and Getting Permission from concern department including all required payment to concern department including getting N.O.C. after completion of work from concern authority. For National Highway Crossing and State Highway Crossing Horizontal Drilling-900:and MS Casing Pipe-800 thick:12 for 610 mm Dia M.S carrying pipe
Drilling of Horizontal bore hole for water main pipeline under the Railway/ Road tracks in all strata with required length includes the cost of drilling of bore hole, Casing pie and welding pushing etc complete but excluding the cost of water main, valves and other items, entire work should be as per approved drawing and as per instruction of Railway/Road authority for following diameter of bore hole for MS pipe and The Rate Include Preparation of Plan, Design , Drawing and Getting Permission from concern department including all required payment to concern department including getting N.O.C. after completion of work from concern authority. For National Highway Crossing and State Highway Crossing.Horizontal Drilling-600:and MS Casing Pipe-500 thick:8 For 315 mm Dia M.S carrying pipe
Drilling of Horizontal bore hole for water main pipeline under the Railway/ Road tracks in all strata with required length includes the cost of drilling of bore hole, Casing pie and welding pushing etc complete but excluding the cost of water main, valves and other items, entire work should be as per approved drawing and as per instruction of Railway/Road authority for following diameter of bore hole for MS pipe and The Rate Include Preparation of Plan, Design , Drawing and Getting Permission from concern department including all required payment to concern department including getting N.O.C. after completion of work from concern authority. For National Highway Crossing and State Highway Crossing .Horizontal Drilling-1300:and MS Casing Pipe-1200 thick:16 for 914 mm Dia M.S carrying pipe
Item Description
Full Bore Electromagnetic Flow Meter- Inbuilt Battery Power operated esign, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow meter with factory calibration, Inbuilt Battery Power Operated, flanged connection, Flow sensor, Indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardwares, etc complete as per following specifications: Flow Meter/ Sensor: DC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode, Neoprene/Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, CS flanges. Flow Transmitter/ Converter ( Remote Field Mounted): Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate, forward, reverse, sum totaliser display, ±0.5percentage accuracy at 0.3 to 4 m/sec velocity, one scalable pulse/ one status, one Modbus output, one GPRS/ GSM output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to transmitter communication, Minimum 5 years battery lifetime, 3.6 VDC Non Rechargeable Lithium-thionyl chloride/ Ni-Cd high power batteries, Hourly Basis Worldwide transmission of measured data and events via e‐mail and SMS by integrated GSM/GPRS modem, Reliable data storage facility through integrated SD card etc alongwith wall mounted/ stand mounted cabinet. 300 mm Nominal Bore For Jalida + Bhimgadh + Kundhana + Pachvada MIS with 1.5 x 1.5 Sq.mt Chamber
Full Bore Electromagnetic Flow Meter- Inbuilt Battery Power operated esign, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow meter with factory calibration, Inbuilt Battery Power Operated, flanged connection, Flow sensor, Indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardwares, etc complete as per following specifications: Flow Meter/ Sensor: DC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode, Neoprene/Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, CS flanges. Flow Transmitter/ Converter ( Remote Field Mounted): Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate, forward, reverse, sum totaliser display, ±0.5percentage accuracy at 0.3 to 4 m/sec velocity, one scalable pulse/ one status, one Modbus output, one GPRS/ GSM output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to transmitter communication, Minimum 5 years battery lifetime, 3.6 VDC Non Rechargeable Lithium-thionyl chloride/ Ni-Cd high power batteries, Hourly Basis Worldwide transmission of measured data and events via e‐mail and SMS by integrated GSM/GPRS modem, Reliable data storage facility through integrated SD card etc alongwith wall mounted/ stand mounted cabinet. 600 mm Nominal Bore For For TT Dam + Gunda + Tikariyala + Moldi + Zinzuda + Chanpa + Mesariya MIS with 1.5 x 1.5 Sq.mt Chamber
Construction of Energy Dissipation structure at the end of pipe for connection to pond including construction of headwall, wing wall, Endwall, pedestial for bellmouth, Pitching etc complete as per site condition For 315 mm dia m Pipe.
Construction of Energy Dissipation structure at the end of pipe for connection to pond including construction of headwall, wing wall, Endwall, pedestial for bellmouth, Pitching etc complete as per site condition For 600 mm dia m Pipe.
Construction of Energy Dissipation structure at the end of pipe for connection to pond including construction of headwall, wing wall, Endwall, pedestial for bellmouth, Pitching etc complete as per site condition For 900 mm dia m Pipe.
Item Description
PUMP MOTOR SET - Supply, delivery, erection, testing and commissioning approved make Verticle Turbine pump set of required capacity and head with suitable of Pump and Motor having following parameters, along with others, complete as per relevant IS, Data Sheet and Tender Specifications with CFD (computational Fluid Mechanics) FOR MPS Flow - 2549 m3/Hr Head - 123 Mtr Qty - 5 Nos (4 Working + 1 Standby)
PUMP MOTOR SET - Supply, delivery, erection, testing and commissioning approved make Verticle Turbine pump set of required capacity and head with suitable of Pump and Motor having following parameters, along with others, complete as per relevant IS, Data Sheet and Tender Specifications with CFD (computational Fluid Mechanics) FOR PS -1 Flow - 2498 m3/Hr Head - 81 Mtr Qty - 5 Nos (4 Working + 1 Standby)
PUMP MOTOR SET - Supply, delivery, erection, testing and commissioning approved make Verticle Turbine pump set of required capacity and head with suitable of Pump and Motor having following parameters, along with others, complete as per relevant IS, Data Sheet and Tender Specifications with CFD (computational Fluid Mechanics) FOR PS -2 Flow - 1096 m3/Hr Head - 48 Mtr Qty - 3 Nos (2 Working + 1 Standby)
FOR MPS AND PS - 1 DELIVERY PIPE AND SPECIALS - Design, manufacturing, Supply, delivery, erection, testing and commissioning of MS Pipes with inside food grade epoxy and Outside epoxy coating for delivery piping of all the pumps including specials for mechanical joints complete with cutting and welding for providing bends and other specials as per specifications. 610 MM dia x 6.3 mm thick, MS Pipes (for Pump Delivery Side)
FOR PS - 2 DELIVERY PIPE AND SPECIALS - Design, manufacturing, Supply, delivery, erection, testing and commissioning of MS Pipes with inside food grade epoxy and Outside epoxy coating for delivery piping of all the pumps including specials for mechanical joints complete with cutting and welding for providing bends and other specials as per specifications. 406.4 MM dia x 6.3 mm thick, MS Pipes (for Pump Delivery Side)
FOR MPS And PS - 1 Design, manufacturing, Supply, delivery, erection, testing and commissioning of MS Pipes with inside food grade epoxy and Outside epoxy coating for delivery piping of all the pumps including specials for mechanical joints complete with cutting and welding for providing bends and other specials as per specifications. 1219 MM dia x 10 mm thick, MS Pipes (For Header Pipe)
FOR PS-2 Design, manufacturing, Supply, delivery, erection, testing and commissioning of MS Pipes with inside food grade epoxy and Outside epoxy coating for delivery piping of all the pumps including specials for mechanical joints complete with cutting and welding for providing bends and other specials as per specifications. 711 MM dia x 7.1 mm thick, MS Pipes (For Header Pipe)
FOR MPS And PS-1 Design, manufacturing, Supply, delivery, erection, testing and commissioning of Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following thickness outside diameter at GWSSB store or site anywhere in Gujarat State including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete. (for pump set) 273 mm X 4 mm Thick M.S. Pipe for Header Bypass
FOR PS-2 Design, manufacturing, Supply, delivery, erection, testing and commissioning of Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following thickness outside diameter at GWSSB store or site anywhere in Gujarat State including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete. (for pump set) 113 mm X 4 mm Thick M.S. Pipe for Header Bypass
FOR MPS , PS-1 And PS-2 Design, manufacturing, Supply, delivery, erection, testing and commissioning of Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following thickness outside diameter at GWSSB store or site anywhere in Gujarat State including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete. (for pump set) 113 mm X 4 mm Thick M.S. Pipe for Delivery Bypass
FOR MPS And PS-1 Design, manufacturing, Supply, delivery, erection, testing and commissioning of MS Pipes for delivery, Header, By pass piping of all the pumps including specials for mechanical joints complete with cutting and welding for providing bends, Nut Bolts, washers and other specials as per specifications.
FOR PS - 2 Design, manufacturing, Supply, delivery, erection, testing and commissioning of MS Pipes for delivery, Header, By pass piping of all the pumps including specials for mechanical joints complete with cutting and welding for providing bends, Nut Bolts, washers and other specials as per specifications.
FOR MPS And PS-1 Supply, Installation of Structure Steel at site of work with freight, loading, unloading carting, etc. including all taxes and duties complete such as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered plates (below 10mm thickness) for cable trench etc. required for support structure of all Electro-mechanical equipment, piping, etc. for support on floor / wall / beam / brackets etc. as per tender and IS.
FOR PS - 2 Supply, Installation of Structure Steel at site of work with freight, loading, unloading carting, etc. including all taxes and duties complete such as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered plates (below 10mm thickness) for cable trench etc. required for support structure of all Electro-mechanical equipment, piping, etc. for support on floor / wall / beam / brackets etc. as per tender and IS.
FOR MPS And PS-1 BUTTERFLY VALVES - Supply, delivery, Installation, testing and commissioning of DI, D/F, Electrically operated Butterfly Valve with by-pass arrangement of mentioned class and diameter including all pipes and specials as specified in specifications, data sheet and as per relevant IS or equivalent code. DN - 600mm, Rating – PN 1.6 (Pump Delivery Pipe)
FOR PS-2 BUTTERFLY VALVES - Supply, delivery, Installation, testing and commissioning of DI, D/F, Electrically operated Butterfly Valve with by-pass arrangement of mentioned class and diameter including all pipes and specials as specified in specifications, data sheet and as per relevant IS or equivalent code. DN - 400mm, Rating – PN 1.6 (Pump Delivery Pipe)
FOR MPS And PS-1 DPCV VALVES - Supply, delivery, Installation, testing and commissioning of DI, Dual plate check valve of following sizes and rating, conforming to API 594/ 598 with all necessary hardware including all pipes and specials as specified in technical specifications and data sheet DN - 600mm (PN 1.6) (Pump Delivery Pipe)
FOR MPS And PS-1 DPCV VALVES - Supply, delivery, Installation, testing and commissioning of DI, Dual plate check valve of following sizes and rating, conforming to API 594/ 598 with all necessary hardware including all pipes and specials as specified in technical specifications and data sheet DN - 400mm (PN 1.6) (Pump Delivery Pipe)
FOR MPS And PS - 1 HEADER LINE VALVES - Supply, delivery, Installation, testing and commissioning of DI, D/F, Electrically operated Butterfly Valve with by-pass arrangement of mentioned class and diameter including all pipes and specials as specified in specifications, data sheet and as per relevant IS or equivalent code. DN - 1200mm, (PN - 1.6) (For Header Line)
FOR PS - 2 HEADER LINE VALVES - Supply, delivery, Installation, testing and commissioning of DI, D/F, Electrically operated Butterfly Valve with by-pass arrangement of mentioned class and diameter including all pipes and specials as specified in specifications, data sheet and as per relevant IS or equivalent code. DN - 700mm, (PN - 1.6) (For Header Line)
FOR MPS And PS-1 EXPANSION BELLOWS - Supply, delivery, Installation, testing and commissioning of metallic expansion of following size and rating with flanged ends with tie rods, nuts etc. Complete as per data sheet and technical specifications. DN - 600mm, Rating – PN 1.6(Delivery Side)
FOR PS-2 EXPANSION BELLOWS - Supply, delivery, Installation, testing and commissioning of metallic expansion of following size and rating with flanged ends with tie rods, nuts etc. Complete as per data sheet and technical specifications. DN - 400mm, Rating – PN 1.6(Delivery Side)
FOR MPS And PS-1 EXPANSION BELLOWS - Supply, delivery, Installation, testing and commissioning of metallic expansion of following size and rating with flanged ends with tie rods, nuts etc. Complete as per data sheet and technical specifications. DN - 1200mm, Rating – PN 1.6 (Header Side Near Flowmeter)
FOR PS - 2 EXPANSION BELLOWS - Supply, delivery, Installation, testing and commissioning of metallic expansion of following size and rating with flanged ends with tie rods, nuts etc. Complete as per data sheet and technical specifications. DN - 700mm, Rating – PN 1.6(Header Side Near Flowmeter)
FOR MPS, PS -1 And PS - 2 Air Valve - Supply, Installation, Testing And Commissioning of DI Tempor proof Flanged Air Valve with Isolation Sluice Valve as per IS 14845 PN- 1.0 and IS-14846 PN-1.0 respectively with SS304 float, gun metal nozzle, complete hardware's, bolts, nuts and washers, gaskets etc. including all taxes, Insurance, Transportation, freight charges, Inspection charges, loading, unloading, conveyance to departmental stores, stacking, security etc. as per IS and Specification. Size: 150 mm NB - Pn 1.0 (On Heder line outside the Pump house)
FOR MPS And PS-1 EOT CRANE - Design, Manufacturing, supplying, and Erecting fully electrically operated Double Girder EOT Crane with cross travel, long travel and electrically operated hoist with suitable rating motors having IP64, control panel with hoisting motor, wire rope drum, wire rope, rope sheaves, hooks, spring set, friction shoe type electromagnetic brakes for hoisting and travel motions, pendant control with cable flexible trailing cable, limit switches, travel stops, earthing terminals and other accessories etc. complete as per data sheet, specifications and relevant IS code. Capacity – minimum 15 T, Span – minimum 7 meter, Lifting Height – minimum 10 meter, Runway length – minimum 15 m
FOR PS-2 EOT CRANE - Design, Manufacturing, supplying, and Erecting fully electrically operated Double Girder EOT Crane with cross travel, long travel and electrically operated hoist with suitable rating motors having IP64, control panel with hoisting motor, wire rope drum, wire rope, rope sheaves, hooks, spring set, friction shoe type electromagnetic brakes for hoisting and travel motions, pendant control with cable flexible trailing cable, limit switches, travel stops, earthing terminals and other accessories etc. complete as per data sheet, specifications and relevant IS code. Capacity – minimum 7.5 T, Span – minimum 7 meter, Lifting Height – minimum 10 meter, Runway length – minimum 15 m
FOR MPS, PS-1 And PS-2 EOT CRANE - Design, Manufacturing, supplying, and Erecting fully electrically operated Single Girder EOT Crane long travel, Up Down and electrically operated hoist with suitable rating motors having IP64, control panel with hoisting motor, wire rope drum, wire rope, rope sheaves, hooks, spring set, friction shoe type electromagnetic brakes for hoisting and travel motions, pendant control with cable flexible trailing cable, limit switches, travel stops, earthing terminals and other accessories etc. complete as per data sheet, specifications and relevant IS code. Capacity – minimum 5 T, Lifting Height – minimum 10 meter, length – minimum 10 m (For Screen)
FOR MPS, PS-1 And PS-2 DEWATRING PUMPSETS - Providing and erecting approved make Horizontal monoset submersible pumpsets having flow rate Minimum 50 m3/hr. and 10 meters working on three phase 50 Hz,415 V±10percentage with DOL starter, cable, GI medium duty delivery pipes, specials, suction strainer etc. complete set Material of Constructions: Impeller- High tensile brass / LTB II; Casing- CI FG 260; Pump and Motor shaft- SS 304; Bearing Bush- LTB III as per Datasheet and Technical Specifications.
FOR MPS And PS-1 Supply, delivery, Installation, testing and commissioning of DI, D/F, Manually operated Sluice valve of mentioned class and diameter as specified in specifications, as per relevant IS or equivalent code. Size - 100 mm (PN-1.6) (Delivery ByPass)
FOR PS-2 Supply, delivery, Installation, testing and commissioning of DI, D/F, Manually operated Sluice valve of mentioned class and diameter as specified in specifications, as per relevant IS or equivalent code. Size - 100 mm (PN-1.6) (Delivery ByPass and Header ByPass)
FOR MPS And PS - 1 Supply, delivery, Installation, testing and commissioning of DI, D/F, Manually operated Sluice valve of mentioned class and diameter as specified in specifications, as per relevant IS or equivalent code. Size - 250 mm (PN-1.6) (Header ByPass)
FOR MPS And PS - 1 Design, Manufacturing, Supply, Delivery, Installation, Testing and Commissioning of Fire Fighting System as per latest norms. Fire Fighting Pump House, Hydrant System, Electrical Panel, Fire Extinguisher as per Tender document and latest norms.
Designing and constructing R.C.C. Thrust Block with Controlled cement concrete using cement, sand and crushed aggregate by mass and machine mix for R.C.C/CC work including necessary formworks centering scaffolding compaction by mechanical vibrator,curing as directed with all lead and lift etc complete Including the cost of reinforcement. For Thrust block Concrete grade M-20 and MSA - 20 mm for Pump Room in MPS, IPS-1 and IPS-2
Item Description
FOR MPS And PS-1 66 kV Switchyard :- 66 kV Outdoor Switchyard - 66 kV Switchyard including lightning arrestor, Isolator, CT-PT,PI unit, Circuit breaker, Steel Structure, Earthing System, Relay control Panel, Cable and cable containment system, Lightning system, Fire fighting system, civil work and all accessories complete for efficient and trouble free operation etc. complete as per specifications and as directed by the Engineer-in-Charge.
FOR MPS Power Transformer - Design, supply, receiving, storing, inspection, handling , assembling, installing in correct aligned position, effecting proper connections, testing and commissioning of outdoor type, three phase, oil immersed, power transformer of required KVA and voltage ratio, copper double wound, vector group - Dyn11, HV delta connected and LV star connected with neutral brought out connected to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS: 2026 - 2011 with its latest amendment including first fill of transformer oil and following accessories. (a) Oil conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating breather charged with silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e) Lifting Eyes / Hooks / Lugs (f) Two earthing terminal (g) Diagram and rating plate (h) Air release plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-directional plain roller with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit externally operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature indicator (For rating < 500 kVA) (o) Bucholtz relay with shut off valve (For rating Greater or Equal to 500 KVA) (p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating Greater or Equal to 500 kVA) (q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating Greater or Equal to 1000 kVA) (r) Marshalling box (For rating Greater or Equal to 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating Greater or Equal to 1600 kVA) (t) Inspection cover and Jacking lugs (For rating Greater or Equal to 1600 kVA) For transformer rating of 1600 KVA and higher nitrogen injection fire protection system (NIFPS) is to be provided. With on load tap changer +10percentage to -10percentage in steps of 1.25percentage with RTCC and AVR And as specified in Technical specification and data sheet and relevant IS with Transfomation Foundation Casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced cement concrete in M 20 using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work including providing of 53 grade cement and Fe 415 grade TMT bars, scaffolding, centering, form work, curing etc. complete. RCC plinth / foundation for distribution transformer of capacity. Foundation Size - 3000 X 2500 X 500 Size - 10000 KVA (66/6.6 KV)
For PS - 1 Power Transformer - Design, supply, receiving, storing, inspection, handling , assembling, installing in correct aligned position, effecting proper connections, testing and commissioning of outdoor type, three phase, oil immersed, power transformer of required KVA and voltage ratio, copper double wound, vector group - Dyn11, HV delta connected and LV star connected with neutral brought out connected to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS: 2026 - 2011 with its latest amendment including first fill of transformer oil and following accessories. (a) Oil conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating breather charged with silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e) Lifting Eyes / Hooks / Lugs (f) Two earthing terminal (g) Diagram and rating plate (h) Air release plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-directional plain roller with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit externally operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature indicator (For rating < 500 kVA) (o) Bucholtz relay with shut off valve (For rating Greater or Equal to 500 KVA) (p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating Greater or Equal to 500 kVA) (q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating Greater or Equal to 1000 kVA) (r) Marshalling box (For rating Greater or Equal to 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating Greater or Equal to 1600 kVA) (t) Inspection cover and Jacking lugs (For rating Greater or Equal to 1600 kVA) For transformer rating of 1600 KVA and higher nitrogen injection fire protection system (NIFPS) is to be provided. With on load tap changer +10percentage to -10percentage in steps of 1.25percentage with RTCC and AVR And as specified in Technical specification and data sheet and relevant IS with Transfomation Foundation Casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced cement concrete in M 20 using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work including providing of 53 grade cement and Fe 415 grade TMT bars, scaffolding, centering, form work, curing etc. complete. RCC plinth / foundation for distribution transformer of capacity. Foundation Size - 3000 X 2500 X 500 Size - 6300 KVA (66/6.6 KV)
FOR PS - 2 Power Transformer - Supply, Installation, Testing And Commissioning of outdoor type, three phase, oil immersed, power transformer of required KVA and voltage ratio, copper double wound, vector group - Dyn11, HV delta connected and LV star connected with neutral brought out connected to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS: 2026 - 2011 with its latest amendment including first fill of transformer oil and following accessories. (a) Oil conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating breather charged with silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e) Lifting Eyes / Hooks / Lugs (f) Two earthing terminal (g) Diagram and rating plate (h) Air release plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-directional plain roller with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit externally operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature indicator (For rating < 500 kVA) (o) Bucholtz relay with shut off valve (For rating ≥ 500 KVA) (p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating ≥ 500 kVA) (q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating ≥ 1000 kVA) (r) Marshalling box (For rating ≥ 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating ≥ 1600 kVA) (t) Inspection cover and Jacking lugs (For rating ≥ 1600 kVA) With off load tap changer +10percentage to -10percentage in steps of 2.5percentage with Casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced cement concrete in M 20 using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work including providing of 53 grade cement and Fe 415 grade TMT bars, scaffolding, centering, form work, curing etc. complete. RCC plinth / foundation for distribution transformer of capacity. Foundation Size - 1750 X 1750 X 1000. Size - 800 KVA (11/0.433 KV)
FOR MPS AND PS - 1 Auxiliary Transformer - Design, supply, receiving, storing, inspection, handling , assembling, installing in correct aligned position, effecting proper connections, testing and commissioning of outdoor type, three phase, oil immersed, distribution transformer of required KVA and voltage ratio, copper double wound, vector group - Dyn11, HV delta connected and LV star connected with neutral brought out connected to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS: 1180 (Part-1) / 2021 with its latest amendment including first fill of transformer oil and following accessories. (a) Oil conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating breather charged with silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e) Lifting Eyes / Hooks / Lugs (f) Two earthing terminal (g) Diagram and rating plate (h) Air release plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-directional plain roller with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit externally operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature indicator (For rating < 500 kVA) (o) Bucholtz relay with shut off valve (For rating Greater or Equal to 500 KVA) (p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating Greater or Equal to 500 kVA) (q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating Greater or Equal to 1000 kVA) (r) Marshalling box (For rating Greater or Equal to 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating Greater or Equal to 1600 kVA) (t) Inspection cover and Jacking lugs (For rating Greater or Equal to 1600 kVA) For transformer having oil storage capacity for 2000 liters and higher, nitrogen injection fire protection system (NIFPS) is to be provided. With off circuit tap changer +10percentage to -10percentage in steps of 2.5percentage And as specified in Technical specification and data sheet and relevant IS with Transformer foundation casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced cement concrete in M 20 using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work including providing of 53 grade cement and Fe 415 grade TMT bars, scaffolding, centering, form work, curing etc. complete. RCC plinth / foundation for 200 KVA Transformer of capacity Less or Equal to 315 KVA,Plinth Dimension 1250 X 1250 x 1500 mm Size - 250 KVA (6.6/0.433 KV) Efficiency Level - 2
FOR MPS And PS-1 6.6kV Metal Enclosed Switchgear (HT PANEL) -Design, engineerig, procurement, installation, testing and commissioning of 6.6KV, 02 nos as Incomer 1250 A EDO type draw out VCB breakers and 01 nos as Bus Coupler 1250 A EDO type draw out VCB, 07 nos 800 Amp, EDO type, draw out VCB breakers for motor feeder, 02 nos 800 Amp, EDO type, draw out VCB breakers for Auxiliary Transformer Control feeder, 02 Nos Bus PT conforming to IS 2516 and latest amendment , 3 Phase , 50 Hz unearthed A.C. supply system , with spring operated mechanisam, Electrical closing coil and 02 Nos.Tripping Coil operating on 110V DC supply, manually ON-OFF and spring operated mechanically charged, discharged indiactor,mechanical interlock safty shutters, isolating plugs, Multi function meter with RS-485, Energy meter, Analogue Ammeter and all associated equipments and accessories as per tender specification etc.. All feeder shall be suitable for PLCSCADA compatible. with all other accessories for satisfactory operation as per detail specification , as required by the statutory electrical authorities guidelines etc. Complete as per specifications and as directed by the Engineer in Charge. And as specified in Technical specification and data sheet and relevant IS.
FOR MPS (a) 6.6KV SOFT STARTER PANEL : Design, engineering, procurement, installation, testing and commissioning of Fully automatic microprocessor based or FCMA or HSFR type soft starter suitable for 1200 KW squirrel cage induction motor, 6.6 KV, 3 phase, 50 Hz with built in bypass terminal for pump control application as per latest IS, tender specification and technical datasheet. Input Voltage- 3 phase , 6.6KV Input Frequency - 50 Hz (+/- 5 percentage) Starter Protection - S/C,u/Phase unbalance, Phase failure Built in communication as per RS 485, Under Voltage release type, Earth Fault Release EF1 (10percentage,20percentage Ir), Door Inter Lock, PLC-SCADA compatibility. (b) 6.6 KV HT CAPACITOR PANEL FOR MOTOR Design, engineering, procurement, installation, testing and commissioning of Capacitor Panel for 6.6 kV HV Motor Capacitor panel consist of 6.6 kV off load Isolator, HV fuse, series detuned reactor and capacitor unit with comprehensive protection i.e. Under voltage, over voltage, neutral voltage displacement / Neutral current transformer, internal discharge resistor etc. 400 KVAr capacitor bank for continuous duty to improve power factor up to 0.99 with bus-bar chamber having 2 mm thick sheet steel enclosure with earth terminals and all necessary protective equipments and accessories with IP 42 protection etc.
FOR PS - 1 (a) 6.6KV SOFT STARTER PANEL : Design, engineering, procurement, installation, testing and commissioning of Fully automatic microprocessor based or FCMA or HSFR type soft starter suitable for 750 KW squirrel cage induction motor, 6.6 KV, 3 phase, 50 Hz with built in bypass terminal for pump control application as per latest IS, tender specification and technical datasheet. Input Voltage- 3 phase , 6.6KV Input Frequency - 50 Hz (+/- 5 percentage) Starter Protection - S/C,u/Phase unbalance, Phase failure Built in communication as per RS 485, Under Voltage release type, Earth Fault Release EF1 (10percentage,20percentage Ir), Door Inter Lock, PLC-SCADA compatibility. (b) 6.6 KV HT CAPACITOR PANEL FOR MOTOR Design, engineering, procurement, installation, testing and commissioning of Capacitor Panel for 6.6 kV HV Motor Capacitor panel consist of 6.6 kV off load Isolator, HV fuse, series detuned reactor and capacitor unit with comprehensive protection i.e. Under voltage, over voltage, neutral voltage displacement / Neutral current transformer, internal discharge resistor etc. 250 KVAr capacitor bank for continuous duty to improve power factor up to 0.99 with bus-bar chamber having 2 mm thick sheet steel enclosure with earth terminals and all necessary protective equipments and accessories with IP 42 protection etc.
FOR MPS NGR - Supply, Installation, testing and commissioning of6.6 KV,4.356 ohm, 874.79 Amp, 10 Secs. Neutral Grounding Resistors as per tender specification.
PS - 1 NGR - Supply, Installation, testing and commissioning of 6.6 KV,6.914 ohm, 551.12 Amp, 10 Secs. Neutral Grounding Resistors as per tender specification.
FOR MPS And PS - 1 LT PMCC Panel - Supply, installaton, testing and commissioning MCC panel, totally enclosed type as per IS: 2147 and latest amendment, operation on three phase, 415V, 50Hz,neutral effectively grounded, IP 54, with instrument compartments indicating lamps, control contactors as per IS: 13947, relays and control fuses air insulated control method- Torque control, Input Voltage- 3 phase 415 V, Input Frequency - 50 Hz (+/- 3 percentage), Starter Protection - S/C,u/V,Phase unbalance,Phase failure, Built in communication as per RS 485, Under Voltage release type 415V, Earth Fault Release EF1 (10percentage,20percentage Ir), Door Inter Lock. Incomer Feeder: 400 A, MCCB -2 Nos., 400 Amp Bus Coupler - 2 Nos, 150 Amp MCCB For Dg Set - 1 Nos; 36kA Utilization Category B'; Ics:Icu:Icw, as per IEC 947(Part2) (2 incomer,1Bus Coupler, 1 DG sets)400A, TPN, 36KA, 1Sec, Aluminum Bus-bar Current transformer 400/5A, Cl :5P10 Current transformer 400/5A, Cl: 1.0Multifunction meter with RS 485 Compatibility with PLC-SCADA. S/C,u/Phase unbalance, Phase failure Built in communication as per RS 485 Under Voltage release type 415V Earth Fault Release EF1 (10percentage,20percentage Ir) Door Inter Lock 110 V DC Control Supply Suitable for PLC -SCADA system etc.LED type indication lamps with protection fuses.Outgoing Feeders: 40A TPN MCB with starter for Drain Pump - 2 Nos., , 125 A TPN MCCB with 100/5 A. Cl. 1.0 CTs (3 Nos.), ASS and Ammeter for Capacitor Bank Panel - 2 Nos, 63 A MCB for Indoor, Outdoor welding socket - 2 Nos., 100A TPN MCCB with 100/5 A. Cl. 1.0 CTs, ASS and Ammeter, for Battery Charger - 1 Nos, 63 AMP TPN MCB Lighting DB - 3 Nos , 63A FP MCB for EOT - 2 Nos, 32A FP MCB for PLC Panel - 1 Nos, 63A MCCB Bore pump panel – 1 no, 32A TPN MCB For Spare - 4 No , 16A DP MCB For Spare - 4 No , 63A TPN MCB For Spare - 3 No , 40A TPN MCB For Spare - 1 No. Spare: All out going motor feeders shall be equipped with ON/OFF/Auto Trip Indicating Lamps, control circuit MCBs, neutral link for control circuits.
FOR MPS And PS - 1 HV Power Cables - Design, Supply, Laying, Tying, Tagging, Testing and Commissioning of 6.6 kV (UE) , XLPE insulated, PVC sheathed, Aluminum conductor, armored cable in constructed cable trench and cable tray conforming to IS: 7098 with its latest amendments and of approved make etc. Complete as per specifications and as directed by the Engineer – in Charge. Size - 3C X 240 Sq mm (UE) (6.6 KV)
FOR PS - 2 HV Power Cables - Design, Supply, Laying, Tying, Tagging, Testing and Commissioning of 11 kV (UE) , XLPE insulated, PVC sheathed, Aluminum conductor, armored cable in constructed cable trench and cable tray conforming to IS: 7098 with its latest amendments and of approved make etc. Complete as per specifications and as directed by the Engineer – in Charge. Size - 3C X 240 Sq mm (UE) (11 KV)
FOR MPS And PS -1 LV cables and Cable tray - Supply and laying in cable Tray/clamped to wall with suitable clamps, saddles and fixing bolts/ in ground including the cost of digging and back filling with sand and brick protection and cable tray as required and including testing and commissioning of the following sizes of 1.1KV grade aluminum conductor XLPE insulated and PVC sheathed armoured cable conforming to IS: 7098 (Part-I) with latest amendments. The rates shall include properly clamping with cable clamps and ties. Identification tags shall be provided for all cables etc. Complete as per specifications and as directed by the Engineer – in Charge. (For further Details, refer Appendix D of Vol III(C) – Technical specifications for Electrical Works)
FOR PS - 2 LV cables and Cable tray - Supply and laying in cable Tray/clamped to wall with suitable clamps, saddles and fixing bolts/ in ground including the cost of digging and back filling with sand and brick protection and cable tray as required and including testing and commissioning of the following sizes of 1.1KV grade aluminum conductor XLPE insulated and PVC sheathed armoured cable conforming to IS: 7098 (Part-I) with latest amendments. The rates shall include properly clamping with cable clamps and ties. Identification tags shall be provided for all cables etc. Complete as per specifications and as directed by the Engineer – in Charge. (For further Details, refer Appendix E of Vol III(C) – Technical specifications for Electrical Works)
FOR MPS And PS -1 Cable Termination Kit and Cable Gland - Supply, Installation, testing and commissioning of the Heat shrinkable type HV cable end and LV cable termination, gland and lugs suitable for indoor and outdoor application Complete as per specifications and as directed by the Engineer – in Charge. (For further Details, refer Appendix F of Vol III(C) – Technical specifications for Electrical Works)
FOR PS - 2 Cable Termination Kit and Cable Gland - Supply, Installation, testing and commissioning of the Heat shrinkable type HV cable end and LV cable termination, gland and lugs suitable for indoor and outdoor application Complete as per specifications and as directed by the Engineer – in Charge. (For further Details, refer Appendix G of Vol III(C) – Technical specifications for Electrical Works)
FOR MPS, PS - 1 And PS -2 Battery and Battery Charger with DCDB - Battery and Battery charger with DCDB etc. Complete as per specification and as directed by the Engineer in charge. (For further Details as per Technical specifications for Electrical Works) and data sheet and relevant IS
FOR MPS, PS - 1 And PS -2 Lighting system - Illumination system complete as per specifications and as directed by the Engineer in Charge (For further Details, refer Appendix H of Vol III(C) – Technical specifications for Electrical Works)
FOR MPS, PS - 1 Wiring, Ceiling Fan, Industrial Exhaust Fan and Other Accessories in Pump House Building, Wiring, Ceiling Fan, Industrial Exhaust fan complete as per specifications and as directed by the Engineer in Charge
FOR PS -2 Wiring, Ceiling Fan, Industrial Exhaust Fan and Other Accessories in Pump House Building, Wiring, Ceiling Fan, Industrial Exhaust fan complete as per specifications and as directed by the Engineer in Charge
FOR MPS, PS - 1 Earthing and Lightning Protection Work, Earthing and Lighting protection work. complete as per specifications and as directed by the Engineer in Charge
FOR PS - 2 Earthing and Lightning Protection Work, Earthing and Lighting protection work. complete as per specifications and as directed by the Engineer in Charge
FOR MPS, PS - 1 Lighting Distribution Board And Power Distribution Board - Supply, Installation, testing , and commissioning of self supported, floor mounted, front operated , cubicle type panel board made out of 14 gauge M.S. sheet complete with equipments etc. complete as per tender specifications and as directed by the engineer Encharge.
FOR PS - 2 Lighting Distribution Board And Power Distribution Board - Supply, Installation, testing , and commissioning of self supported, floor mounted, front operated , cubicle type panel board made out of 14 gauge M.S. sheet complete with equipments etc. complete as per tender specifications and as directed by the engineer Encharge.
FOR MPS, PS -1 And PS -2 Safety Equipments and Accessories - Supply, installation and necessary testing of safety equipment and accessories in switchgear room, transformer yard/sub station and pump house as per latest edition of IS-5216 etc. complete as per specifications and as directed by the Engineer in Charge
Item Description
FOR MPS And PS -1 ELECTRO MAGNETIC FLOWMETER - Design, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow meter with factory calibrated, Regular Power Operated, flanged connection, Flow sensor, Indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardwares, etc complete as per following specifications: DC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode, Neoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, CS flanges. Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate, forward, reverse, sum totaliser display, ±0.5percentage accuracy at 0.3 to 4 m/sec velocity, 4 to 20 mA with HART/Modbus output, one scalable pulse, one status output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to transmitter communication etc alongwith wall mounted/ stand mounted cabinet. size: 100mm (PN 1.6)
FOR PS -2 ELECTRO MAGNETIC FLOWMETER - Design, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow meter with factory calibrated, Regular Power Operated, flanged connection, Flow sensor, Indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardwares, etc complete as per following specifications: DC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode, Neoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, CS flanges. Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate, forward, reverse, sum totaliser display, ±0.5percentage accuracy at 0.3 to 4 m/sec velocity, 4 to 20 mA with HART/Modbus output, one scalable pulse, one status output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to transmitter communication etc alongwith wall mounted/ stand mounted cabinet. Size - 700 mm (PN 1.6)
FOR MPS, PS - 1 And PS-2 Ultra Sonic Level Measuring System - Design, Supply, Installation, Testing and Commissioning of NOn Contact Ultrasonic Type Level Transmitter with Integral Display with conductivity type level switch. Sensor with Head Mounted Transmitter: The sensor should be non contact type, field mounting type, housing shall have minimum IP65 protection, PP/ PVC Sensor MOC, Microprocessor based indicator with LED / LCD digital display,panel/ wall mounting type, power supply shall be 110- 240 Vac or 15 to 36 Vdc, 50 Hz ± 10 percentage. Accesories: Mounting bracket, nut, bolts etc as per system requirement and Hook up diagram of the Instruments. Level Transmitter shall be suitable for following Range. Meas. Range: upto 15 m (at any one compartment of sump)
FOR MPS, PS -1 And PS -2 Float and Board Type Level Indicator Design, Supply, Installation, Testing and Commissioning of Float and Board Type Level Indicator, guided construction, Full Range Travel, FRP/ SS316 MOC of Float and Guide Wire Rope, minimum 6” wide x aluminum powder coating with black graduations and numerical on calibrated gauge board, Red color pointer, protection conduit, Elbow pulley, Tensioner, Anchor, Rope Fastner, Gauge Brackets, Counter Weight for rope type probe, spacer between the probes, etc complete with calibration of following sizes. SIze - up to 12 Mtr
FOR MPS, PS -1 And PS -2 Pressure Measuring System - Design, Supply, Installation, Testing, Commissioning of Bourdon Type Pressure Gauge, ±1percentage accuracy, Direct bottom 1/2" NPT (M) process connection, IP 67, Glycerine filled, SS304 Case with Bayonet Type Bezel, SS316 L Bourdon Tube, SS 316 Movement material, Aluminium dial with black graduation on white background, Micro Zero adjustable pointer, neoprene gasket, Blow out disc, shatter proof glass, SS tag plate etc as per IS 3624. Range : 0 - 20 kg / sq.cm. (150 mm Dial Size)
FOR MPS, PS -1 And PS -2 Pressure Measuring System - Design, Supply, Installation, Testing and Commissioning of Sealed Diaphragm Type Pressure Transmitter with pressure switch. Piezo-resistive sensor technolgy based pressure transmitter with Micro- processor based integral LED/ LCD display, with accuracy of ± 0.3percentage of span, external zero and span adjustment, self diagnostics, temperature sensor for compensation. 15 to 36 V DC power supply, output signal of 4-20 mA DC with HART. Minimum IP 65 degree of protection. Aluminium housing with epoxy coating, Accessories like snubbers for pump discharge applications, three way manifold, mounting brackets, name plate etc. Material for accessories shall be SS. Protection Box/Canopy shall be provided for outside installed transmitters. Range : 0 - 16 Kg/cm2
FOR FOR PS - 1 (Bhapi P.S.) , PS - 2 (Dendua P.S.) And PS-3 (Shera P.S.) INSTRUMENTATION CONTROL PANEL WITH PLC SCADA SYSTEM Design, Supply, Installation, testing and commissioning of Control, Automation, pressure transmitter, UPS and Scada software package with license for pumping station with 32” Monitor, 4GB RAM, 500GB hot swappable internal storage capacity with suitable operating system, Floor mounted front operated cubical panel board having IP 55 protection with announciator with relay based for controlling of flow, level, pressure and 8 nos of temperature scanner for motor winding with necessary wire and accessory and necessary material. PLC Shall have HMI 7 inch HMI display. PLC system shall be 100percentage hot back up with redundancy.
FOR MPS, PS -1 And PS -2 INSTRUMENTATION CABLE ,CCTV CAMERA WITH CABLE TRAY Design, Supply, Installation, testing and commissioning of Intrument cable with cable tray and complete with necessary fixing brackets, other accessories and tools etc. comprising of 8 Cameras for Inside pump house,urrounding area outside pump house, DVR, Hard disc, SMPS, UPS, mounting accessories etc as per tender specification and as per IS.
Providing and erecting water cooler having storage capacity 80Ltr. and cooling capacity 40 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by 15˚ C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete with necessary inlet and outlet connection. The body of water cooler will be made from Stainless Steel. ◦
Supplying and erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, prefilter housing with 'O' ring presediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 psi inline type post carbon filter auto low and high pressure switches with following size of storage tank and LPH capacity and erected as directed [A] 10 Ltr / Hr with 7 Ltr StorageTank
Providing and erecting approved make split air-conditioning unit consisting of copper condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes powder coated Stand, Eco Friendly green gas charging, 15A plug top and Remote Control) with necessary core cutting. (b) for 1.5 ton capacity (3 Star Rating)
Item Description
Total Cost of all additional itmes to be carried out as per Price Schedule-E (as scan and uploaded)
Item Description
Total for 10 Years Lump Sump Value of (I) Sub Total The Lump Sump Value quoted must be equal or greater than 3 Percentage of Sub Total (Schedule A1 +A 2+B+C+D+E)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02 Vol II (A)-Tec. Spec. for Civil work_22-01-26.pdf
03. Vol II (B) Technical Specification for Mech_20.01.26.pdf
04. Vol II (C) Technical Specification for Elect._20.01.26.pdf
05 volI (D)Technical specification for inst._27-01-26.pdf
06 Vol II(E) O and M_27.01.2026.pdf
07 Vol IV Price Bid_Without Price_03-02-26.pdf
08 Volume V_Drawings_22.01.2026_11zon.pdf
01 Vol 1 SBD_R2_03.02.2026.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .