Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-Finance HARIGAON PARUA PO NIKAMIL SATRA DISTTT SONITPUR ASSAM PIN 784154 | SONITPUR | ASSAM | 784154 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹26.5 L+₹3.9 L (17.1%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹27.0 L+₹4.4 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹27.3 L+₹4.6 L (20.4%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹27.6 L+₹4.9 L (21.7%)Rejected-Finance GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
Refer Docs
EMD Value
₹53,400
Closing Date
18 Oct 2021, 6:00 pmClosed
GE (N) Tezpur
GE (N) Tezpur C/o 99 APO
REPAIR/REPLACEMENT OF POINT WIRING AND CONNECTED ITEMS IN CERTAIN OTM ACCN AT NAA UNDER GE (N) TEZPUR
2021_MES_476528_1
GE(N)/TEZ/2021-22/8539
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (N) Tezpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE (N) Tezpur
₹53,400
Yes
9 Dec 2021
20 Sept 2021
20 Oct 2021
20 Sept 2021
18 Oct 2021
4 Oct 2021
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete fitting such as switches , ceiling rose pendent, regulators, sockets light fitting etc to be measured separately) removing material from site and making good disturbed surface of wall floor etc complete all as specified and as directed.
Taking down main switches and DBs of any type and make including wooden board/ junction box. removing material from site and making good disturbed surface of wall floor etc complete all as specified and as directed.
Material and labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade drawn in and including PVC casing and capping of size 25/32 mm fixed to wall ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover for mounting of switches, sockets etc incl 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductor connected to common earth dolly for all as directed and specified for the followings.
One light /fan/exhaust fan/bell point controlled by one switch
One bell /buzzer point controlled by one buzzer switch
One 3 pin socket outlet 5 Amps on same board
One 3 pin socket outlet 5 Amps on indpendent board
All as per item No.3 above but with 2.50 sqmm single core multistranded copper conductor cable for 4x1 number 3/5 pin 5/6 Amp socket outlet on independent board. (Note switch socket will be measure and paid seperately).
All as per item No.3 above but with 2.50 sqmm single core multistranded copper conductor cable for 2x1number 3/5 pin 5/6 Amp socket outlet on independent board. (Note switch socket will be measure and paid seperately).
All as per item No.3 above but with 2.50 sqmm single core multistranded copper conductor cable for 3/5 pin 15 Amp socket outlet on independent board.
M&L for switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed.
S&F switch bell push flush type 5 Amps complete all as specified and directed.
S&F switch socket combination 2 in 1 , 5 pin , 5 Amp flush type ISI marked, all as specified and directed.
S&F socket combination outlet 2 in 1, 5 Pin, 5 and 15 Amp flush type ISI marked , all as specified and directed.
S&F socket out let only, 3 pin 5 Amps flush type controlled by another 5 Amps switch complete all as specified and directed.
S&F call bell buzzer AC 230 Volts single pole complete all as specified and directed.
Supply and fixing LED luminaires, 20 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, wit high transmissivity diffuser, high lumen output, with suitable electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of size 23/0.0076, from conector and ceiling rose, complete all as specified and directed.Make- CG OR Equivalent in Bajaj / Philips.
S& F linear & compact 9/10 Watt mirror light, warm whitewith aluminium housing & integrated electronic driver having THD<20% .
Supply & Fix in replacement new generation energy saving and environmental frindly long life 25W LED security lights made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP 66 protection and impact resistance of IK07.fixed with necessary brackets (made out of 32mm bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc to be fixed on walls complete all as specified and directed.
Supply and Fixing in replacement Recess mounting 2' x 2', LED light, having LED driver and surge protection device IP65 luminaire bottom opening SS frame, dust free and zero maintainence complete all as specified and as directed.
Taking down old Supply and Fixing in replacement of LED Driver 24W with surge protection device of recess mounting 2' x 2', LED light luminaire, IP65, complete all as specified and as directed. Make- CG Cat Pt No- SODRVES-36-600-25W & SRPS-5K-440
Taking down ceiling fan any type/ size from hook and dismantling cable and blades and hanging in position after repair, greasing etc. with existing flexible copper cable complete all as directed.
Taking down burnt/unserviceable sub main wiring any size complete and making good disturbed surfaces of walls all as specified and directed.
Supply and draw submain wiring with two single core 6 sq mm FRLSH, PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in PVC cassing n capping including 6 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete.
Supply & fixing in replacemant sheet metal double door enclosure for MCB DBs SPN 8 way 240 V, complete flush mounted all as specified and as directed.
Supply & fixing in replacemant for sheet metal enclosure for DBs SPN 4 way 240 V complete double door, flush mounted all as specified and as directed
M&L for sheet metal double door enclosure for MCB DBs SPN 6 way 240 V, complete flush mounted all as specified and as directed.
M&L for MCB single pole 240 volts 6 to 32 Amps complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts 32 to 40 Amps complete all as specified and directed.
S&F ceiling rose surface backelite Polycarbonate type two to three terminals complete all as specified and directed.
Supply and fix in repairs lamp holder PVC/Polycarbonate type with back plate suitable for batten fitting, straight or angular type
Supply and fix LED BALL LAMP of 10W with Lumen output 1100 and Colour Temp 6500K pendant type fitted suitable for PVC /Poly Carbonate type complete all as specfied and directed Make - Havells Cat Part No.LHLDEBHEML8X010 or equivalent make of Bajaj/Philips.
Supply and fixing in replacement capacitor 2.5 MFD for ceiling fan. complete all as specified and directed
Supply and fixing in replacement capacitor 3.15 MFD for ceiling fan complete all as specified and directed
Supply and fixing in replacement capacitor 4.0 MFD for exhaust fan complete all as specified and directed
Supply and fixing rubber real with bolts, nuts and clamps of suitable for ceiling fan complete all as specified and directed
Supply and fix in repairs fan regulator electronic, step type 240V complete all as specified and directed.
Taking down ceiling fan any type/ size from hook and dismantling cable and blades and bring in to contractor store for repair and hanging ceiling fan in position after repair, greasing etc. with existing flexible copper cable complete all as directed. (rewinding of fan, painting and spare parts required shall be measured and paid separately)
Taking down exhaust fan any type/ size from wall and dismantling sealing cable and dismantling blades and bring in to contractor store for repair and fixing exhaust fan in position after repair, greasing etc. with existing flexible copper cable complete all as directed. (rewinding of fan, painting and spare parts required shall be measured and paid separately)
M&L for rewinding of ceiling fan 1200 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed.
M&L for rewinding of ceiling fan 1400 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed.
M&L for rewinding of exhaust fan 300 to 450 mm sweep after dismantlingand taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed.
Supply and Fixing bearing suitable for ceiling fan 1200mm to 1400mm /exhaust fan of bearing No- 6201/6202 complete all as specified and directed.
Material & labour for providing earthing complete with GI earth plate electrode 60cm x 60cm x6.3mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level) with top edge of the plate at a depth not less than 1.50 mtrs below normal ground level connected to GI wire 4 mm as main earthing lead by means of bolts, nuts and twin washers made out of galvanised iron or steel, provisioning of 15 mm dia medium grade protection pipe and 20 mm dia GI medium grade watering pipe with funnel all as shown in electrical plate No. 3 of SSR Part I and connected to earth test point all as specified and as directed including testing on completion and submission of test report to the department. Note : 1. The rate consider is deemed to include for excavation, earth work, PCC pit, pre cast RCC cover with handle made out of PCC1:2:4, reinforced with 8mm dia TMT bars @ 150 c/c both way , Funnel, Mest, watering pipe, GI Protection Pipe ( Medium Grade), coal dust, salt etc.,
S&F single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240V complete all as specified.
Supply, laying, jointing and testing LT cable in trenches or on poles/walls, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armored , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm, 4 core complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core.
Supply, laying, jointing and testing LT cable in trenches or on poles/walls, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armored , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm, 2 core complete all as specified and directed.
Supply & fixing GI Pipe light grade 40 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc fixed complete to walls and ceilings or laid in floors complete all as specified and directed..
Supply & fixing GI Pipe medium grade 50 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc fixed complete to walls and ceilings or laid in floors/ in below road by manual boaring complete all as specified and directed..
Excavation in trenches not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil all as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and deposited where directed at a level not exceeding 1.50 meter above the starting point all as directed.
M&L for bricks sub-class 'B' laid in trenches with width equal to width of the brick for the protection of under ground cable complete all as specified in SSR part-I.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable in trenches complete all as specified and directed.
Taking down old recess mounting 2' x 2', LED light luminaire and refixing same after repair or by replacing required item of reccess light complete all as specified and as directed. (Note: LED driver and surge protection device will be measured and paid separately)
Taking down old u/s LT UG Cables of any size from trenches/poles/walls complete after disconnection all as specified and directed
M/S Manjit Singh
M/S L N ENTERPRISE
M/S Harjinder Singh Contractor
M/S MOHANPASARI
D G Corporation
Anil Kumar Sarmah
M/S M N ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .