| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LQualified SHOP NO 1 HOPE TOWN VILLAGE PHANIGHAT NEAR PHANIGHAT JETTY SOUTH ANDAMAN ANDAMAN NICOBAR 744107 UDYAM AN 01 0009045 35DDFPR1399N1ZS B R | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744107 | L1 | Qualified MSE, Category: General | |
| 2 | L2₹6.6 L+₹1.6 L (32.5%)Qualified | L2 | Qualified MSE, Category: General | |
| 3 | L3₹7.2 L+₹2.2 L (44.0%)Qualified 00 NEAR PRIMARY SCHOOL KANHACHATTI RAJPUR CHATRA JHARKHAND 825401 | CHATRA | JHARKHAND | 825401 | L3 | Qualified | |
| 4 | Disqualified HADDO WARF ROAD HADDO PO PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | - | Disqualified MSE, Category: General | |
| 5 | Disqualified | - | Disqualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 Mar 2025, 4:00 pmClosed
Repair
Maintenance
and Installation of Plant Systems/Equipments (Version 2) - ICGS C428; L90 Domestic sea water pump fitted in pump area not getting started On investigation by ships staff suspected that impeller of the same jammed and fault may b..
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L91 01 in no loop of ships fire detection system is showing open loop and mains fault in FDS display Defect to be investigated rectified and proved for satisf..
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L92 01 in no microwave and 02 in nos refrigerators securing arrangement broken view rough sea and general wear and tear Same to be secured with proper securin..
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L93 02 in nos flood light at Qdeck and 02 in nos ay flag deck not working On investigation found that cable from main deck distribution box point of light sho..
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L94 02 in nos portable VHF charger not working and securing rack for 08 in nos VHF has been deteriorated and perished view general wear and tear Same to be re..
Repair
Maintenance
and Installation of Plant Systems/Equipments (Version 2) - ICGS C428; L96 08 in nos flood lights securing clamps and base at weather deck deteriorated and uprooted Base to be prepared welded Clamps to be fabricated as per sample..
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L101 Ships signaling light Morse light not working On investigation found that cable from wheel house junction box to point of light showing open circuit Cabl..
Repair
Maintenance
and Installation of Plant Systems/Equipments (Version 2) - ICGS C428; L102 Bridge and fly bridge command control panels LED buttons bulb not working On defect investigation by ships staff found bulb and button switch control car..
7632899
GEM/2025/B/6046563
Two Packet Bid
Repair
South Andamans, Andaman And Nicobar Islands
Total value wise evaluation
SERVICE
5 documents required · 5 mandatory
1 yrs
₹3
Exempted
18 Mar 2025
18 Mar 2025
28 Mar 2025
and Installation of Plant Systems/Equipments (Version 2) - ICGS C428; L90 Domestic sea water pump fitted in pump area not getting started On investigation by ships staff suspected that impeller of the same jammed and fault may b..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L91 01 in no loop of ships fire detection system is showing open loop and mains fault in FDS display Defect to be investigated rectified and proved for satisf..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L92 01 in no microwave and 02 in nos refrigerators securing arrangement broken view rough sea and general wear and tear Same to be secured with proper securin..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L93 02 in nos flood light at Qdeck and 02 in nos ay flag deck not working On investigation found that cable from main deck distribution box point of light sho..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L94 02 in nos portable VHF charger not working and securing rack for 08 in nos VHF has been deteriorated and perished view general wear and tear Same to be re..
and Installation of Plant Systems/Equipments (Version 2) - ICGS C428; L96 08 in nos flood lights securing clamps and base at weather deck deteriorated and uprooted Base to be prepared welded Clamps to be fabricated as per sample..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS C428; L101 Ships signaling light Morse light not working On investigation found that cable from wheel house junction box to point of light showing open circuit Cabl..
and Installation of Plant Systems/Equipments (Version 2) - ICGS C428; L102 Bridge and fly bridge command control panels LED buttons bulb not working On defect investigation by ships staff found bulb and button switch control car..
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7632899.pdf
GEM_BID
1742293730.pdf
OTHER
1742293744.pdf
OTHER
atc_72d685be-9e3f-45d0-ab5d1741753042698_DTO14.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .