Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | ₹7.8 L Quoted ₹7.9 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹7.9 L+₹154.67 (0.02%)Rejected-Finance | ₹7.9 L+₹154.67 (0.02%) | L2 | Rejected-Finance Being other than lowest tenderer |
| 3 | surinder kumar jindal bros L3₹8.1 L+₹17,355.37 (2.19%)Rejected-Finance | ₹8.1 L+₹17,355.37 (2.19%) | L3 | Rejected-Finance Being other than lowest tenderer |
| 4 | L4₹8.2 L+₹33,252.62 (4.20%)Rejected-Finance | ₹8.2 L+₹33,252.62 (4.20%) | L4 | Rejected-Finance Being other than lowest tenderer |
| 5 | L5₹8.3 L+₹34,448.15 (4.35%)Rejected-Finance | ₹8.3 L+₹34,448.15 (4.35%) | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
12 Mar 2020, 6:00 pmClosed
AGE(I) MES Dharamshala HP
AGE(I) MES Dharamshala HP
SPECIAL REPAIR TO BUILDING NO P-135 AT MIL STN DHARAMSHALA
2020_MES_324902_1
AGE(I)/DSL-52/2019-20
Open Tender
Civil Works
Item Rate
180 days
Military Station Dharamshala
As Per NIT
7 documents required · 7 mandatory
₹500
AGE(I) MES Dharamshala HP
₹19,000
Yes
30 May 2020
14 Feb 2020
20 Mar 2020
14 Feb 2020
12 Mar 2020
28 Feb 2020
Amount
Disconnecting existing tanks of capacity exceeding 250 Ltr and not exceeding 500 Ltr, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position. (cleaning & repairing etc. shall be measured separtely) complete all as specified and directed by the Engr-in-Charge.
Complete removal of existing roof treatment such as old APP membrane, polythene film, mud phuska and the like, with steel were brushing & cleaning top surfaces of cement concrete and removing demolished material not exceeding 50 metre complete all as specified and directed by Engr-in-Charge.
Rendering 10 mm thick in cement mortar 1:3 on concrete surfaces of roof or terrace surface with water proofing liquid compound complete all as specified and directed by Engr-in-Charge. Note : Water proofing liquid shall be measured separately under respective item.
Brushing neat cement slurry with cement 3.00 Kg/sqm complete all as specified and directed by Engr-in-Charge.
Applying a coat of bitumen primer conforming to IS-3384-1996 over plastered @ 0.40 ltrs/sqm of density 0.87-0.89 kg/ltrs at 25 degree celsius and viscosity 70-160 CPS (primer shall be of make as merbrane) including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
APP (atactic Poly-propylene polymer) modified membranes,five layered, 3mm thick weighing not less than 3.5kg/Sqm, having a centre core of polyester non-woven mat (FP) reinforcement dipped in to APP modified mix and sealing all the over laps 75mm on length side and 100mm on width side of membranes by torching as per manufacture's instruction by authorised applicator only after applying evenly a coat of bitumen primer on the bottom of APP and on top of joints of APP complete all as specified and directed by the Engr-in-Charge. (Note: Bitumen primer shall be measured and paid separately)
Taking down cement plaster on brick or stone or concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water complete, all as specified and directed by Engr-in-Charge.
Rendering 15 mm thick on fair faces of brick or concrete surface in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
15 mm thick cement plaster in cement mortar 1:6 on other than fair face of concrete/ brick work surface finished, even and smooth without using extra cement, complete all as specified and directed by the Engr-in-Charge.
5mm thick rendering in CM 1:3 on concrete surfaces as in ceilling, surface finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
Supply only liquid water proofing compound, complete all as specified and directed by the Engr-in-Charge.
Two coats of all weather exterior paint over a coat of primer on walls including prepration of new plastered or unplastered surface, complete all as specified and directed by Engr-in-Charge.
Preparation of old decorated plastered or unplastered wall surfaces including cleaning by brooming down or with steel wire brushing, scrapping down smoke spot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying two coats of all weather exterior paint on walls, complete all as specified and as directed by Engineer-in-Charge.
Preparation of new decorated plastered or unplastered wall surfaces including cleaning by brooming down or with steel wire brushing, scrapping down smoke spot, moulds, moss and efflorescent salts and treating oil and greasy spots etc and applying two coats of oil bound distemper on walls over a coat of chack whitening complete all as specified and as directed by Engineer-in-Charge.
Two coats of oil bound distemper including prepration of surfaces on old plastered surfaces, complete all as specified and directed by Engr-in-charge.
Two coats of white wash on newely plastered surface on ceiling including prepration of surface, complete all as specified and directed by Engr-in-Charge.
Two coats of white wash on old plastered surface on ceilingincluding prepration of surface, complete all as specified and directed by Engr-in-Charge.
Sink made of stainless steel 1mm thick (in replacement) kitchen or laboratory with plugs, washers and wastes,including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including 40mm size CP waste coupling & PVC waste pipe, including demolition of existing terrozo/cement slab sink fixed (in repair), complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete ( unreinforced) in ground floors & paving not exceeding 15 cms thick (below or above ground level), complete all as specified and directed by Engr-in-Charge.
Mirror polished machine cut kota stone slab flooring, 20-25mm thick, over 15mm thick screed bed in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-Charge.
Machine cut, mirror polished Kota stone slab 20-25mm thick as in vertical surfaces such as riser of steps, skirting, dado and pillar, jointed with grey cement slurry mixed with pigment to match the shade of the Kota stone slab including rubbing and polishing, laid over 10mm thick screed bed in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
25mm thick, PCC, M-15, type B-1 (20mm graded stone aggregate) as in flooring to receive floor finishes, complete all as specified and directed by Engr-in-Charge.
Non skid (mat finish) ceramic coloured tiles Primium class-I grade, 7 to 8mm thick (square/rectangular), area of each tiles exc.0.18 sqm but n.exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Non skid (mat finish) ceramic coloured tiles Primium class-I grade, 7 to 8mm thick (square/rectangular), area of each tiles exc.0.18 sqm but n.exc 0.38 sqm as in vertical surfaces such as skirting/ dado etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 10mm thick rendering in CM 1:4 complete all as specified and directed by Engr-in-Charge.
20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillar, window-cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade of granite, complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in- Charge.
Glazed ceramic coloured tiles of size 450mmx300mm,thickness not less than 7mm thick as in vertical concrete /brick surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engr-in- Charge.
Non skid (mat finish) ceramic coloured tiles Primium class-I grade, 7 to 8mm thick (square/rectangular), area of each tiles exc.0.06 sqm but n.exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Demolition of concrete of any description and in any position not otherwise specifically provided for,complete all as specified and directed by the Engr-in-Charge.
75mm thick, plain cement concrete, M-10, type C-2 (using 40 mm graded aggreate as in plinth protection complete all as specified and directed by the Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) of any description area not exceeding 1.5 Sqm each, complete all as specified and directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain PVC sheet reinforced with M.S. Square tube, as per specification & drawing in SSR Part-I complete all as specified and directed by Engr-in- Charge.
Factory made solid panel PVC door shutter 30 mm thick (stile) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing on page No. 156 of MES SSR Part-II 2010, complete all as specified and directed by Engr-in-charge.
100mm long mild steel butt hinges, medium weight, cold rolled complete all as spcified and directed by Engr-in-Charge.
150mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
150mm long aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge.
Taking down steel window with chowkhat of area n. exc. 2.5 sqm each,complete all as specified and directed by the Engr-in-Charge.
Steel windows with side hung shutters including projecting type hinges with steel handles and steel peg stay, complete all as specified and directed by the Engr-in-Charge.
Two coats of synthetic enamel paint over a coat of red oxide zice chrome primer on new or previously untreated steel of steel based surfaces of any description exc 10cm width or girth including preparation of surfaces, complete all as specified and directed by the Engr-in-Charge.
Two coats of synthetic enamel paint on old steel surfaces of any description exc 10cm width or girth including preparation of surfaces, complete all as specified and directed by the Engr-in-Charge.
Easening of steel windows, glazed and gauzed including welding etc. complete all as specified and directed by Engr-in-Charge.
Mild steel peg stay for steel window complete, all as specified and as directed by the Engineer-in-Charge.
Mild steel handle for steel window complete, all as specified and as directed by the Engineer-in-Charge.
Mild steel galvanised wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or wire staples or wooden beads complete, all as specified and directed by Engr-in-Charge.
Taking up or down GI water tubing of 15 mm bore including connections, complete all as specified and directed by Engr-in-Charge.
Taking up or down GI water tubing of 20 mm bore including connections, complete all as specified and directed by Engr-in-Charge.
15mm bore, GI tubing, medium grade, galvanised with all fittings and fixtures fixed to wall and celling or laid in floor, complete all as specified and directed by Engr-in-Charge.
20mm bore, GI tubing, medium grade, galvanised with all fittings and fixtures fixed to walls and celling or laid in floor, complete all as specified and directed by Engr-in- Charge.
15mm bore, Bib taps, chromium plated, Brass with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as spcified and directed by Engr-in-Charge.
15mm, stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions suitable complete fancy type chromium plated, complete all as specified and as directed by Engineer-in-Charge.
Shower rose, 125mm, Chromium plated, with or without swivel joints, any size, including fixing to steel pipe or union, fixed in repair complete all as specified and directed by Engr-in- Charge.
Tubular towel rail, 20mm dia, D-type, 60cm long between flanges aluminium anodised, fixed in repairs complete all as specified and directed by Engr-in-Charge.
PVC valveless, crystal white, syphonic action type flushing cistern, 10 ltr capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32mm dia PVC long bend flush pipe 90cm long and 15mm dia 450 ling PVC Connection with CP brass coupling nuts and PVC washers at bothy ends fixed in repairs complete all as specified and directed by Engr-in-Charge.
Vitreous chinaware squantting pan, ''Orrisa pattern'', size 580mm x 440mm white, with Cast iron 'P' or 'S' trap, front or back inlet, integral footrest excluding flushing cistern and flush type, etc and making good to floors (fixed in repair) complete all as specified and directed by Engr-in-Charge.
PVC (SWR) pipe, 75mm bore, single socketed in any length with rubber ring joint in laid in trenches / floor complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) pipes, single socketed in any length with rubber rings joints laid in trenches or in floor of bore 110mm complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) multi floor trap, plain with granting including jointing with solvent cement, dia of outlet 75mm, fixed in repairs complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) vent cowl of dia 75mm dia fixed in repairs complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) reducer of size 110mm dia fixed in repairs complete all as specified and directed by the Engr-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) form wooden frames or steel, concrete or brick surrounded, glazed with oil putty or fixed with beads complete, all as specified and directed by Engr-in- Charge.
Steel glass 4mm thick ordinary quality and glazing with oil putty/wooden beads in squares not exc. 0.50 sqm in each pane, complete all as specified and directed by Engineer-in-Charge. .
Two coats of synthetic enamel paint on old wood or wooden based surfaces of any description, area not exceeding 10cm width or girth including preparation of surfaces complete, all as specified and directed by Engr-in-Charge.
PVC rotational moulded polyethylene water storage water tank of 500 ltrs capacity (cyclindrical vertical with closed top) hoisted and fixed in position, complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc including removing material for taking credit ( credit shall be recovered as per credit Schedule attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including sunk sheet steel terminal box made out of 1.6 mm thick MS sheet covered with 3 mm thick plastic laminated sheet ( Make Hylum) concealed in wall or on surface as per site requIrement and making good disturbed surfaces of wall for one light point/exhaust fan point etc controlled by one, one way switch complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 66 here-in-above, but for one 3 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 66 here-in-above, but for one 3 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 66 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed by Engr-in-charge.
Socket outlet 2 in 1, 3 pin, 5Amp and 15 Amp flush type complete all as specified and directed by Engr-in-charge.
Switch piano, flush type, single pole, one way,15Amp, complete all as specified and as directed by the Engineer-in-Charge.
Switch piano flush button 5 Amps complete and as directed by the Engineer-in-Charge.
Bell push switch, flush button, single pole, one way 5 Amps complete all as specified and as directed by the Engineer-in-Charge.
Call bell, ding dong, AC 230 volt, single pole, complete all as specified and as directed by the Engineer-in-Charge.
Submain wiring single core PVC insulated and unsheathed cable two run 6 Sqmm multi- strand copper conductor drawing in PVC casing caping with 1x4.0sqmm earth wire as in earth and neutral.complete all as specified and directed by Engr-in-Charge.
Ceiling rose, surface type, 65 mm x 50 mm, two to three terminals/ PVC/ polycarbonate, isolated body fixed on PVC block, complete all as specified and as directed by the Engineer-in-Charge.
Supply & fix (in replacement ) of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 12 way double door type with 200 amp 240 rated bus bar complete all specified and as directed by the Engineer-in-Charge. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing surface.
Supply and fixing MCB SPN 40 Amp, breaking capacity 10 KA, complete all as specified and directed by Engr-in-Charge.
MCB SP 6 to 32 Amp, 10 KA complete, all specified and as directed by the Engineer-in-Charge.
Universal batten for LED Tube suitable for indoor applications tube light fitting 4FT, 1x18w complete all as per Havells Cat Part No reGalBatten5uPto1x18WdsBsWH or equivalatent in Philips/OSRAM/Bajaj.
LED tubelight with very high efficiancy suited for installation in existing batten. complete all as specified and directed by Engr-in-Charge.
Energy efficient LED integrated batten, suitable for indoor applications tube light fitting 1x10 Watt 2 FT complete, Trim LED NEO including all fixing arrangement complete, all as specified and as directed by the Engr-in-Charage. Make: As per Havells Cat Part No LUMILINEPLUS BS10WLED865SPCSS or equivalent in Philips/Bajaj.
1x25 watt Led street light fitting with lamp presure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with GI pipe,1.5mtr length, clamps, nuts, bolts complete all as specified and directed by Engr-in-Charge. Make:- Crompton cat part No. LSTS25CDILED or equivalent in Philips/Syska.
Lamp holder, PVC/ polycarbonate type with back plate, complete all as specified and directed by Engr-in-Charge.
LED Lamp, pin type, 9 watt complete all as specified and directed by Engr-in-Charge. Make:- Polycab Cat Part No LLP0101051 AELIUS LX LED LAMP 9W BC 6500 K or equivalent in Bajaj/CG.
Taking down, re-fixing and connecting the existing serviceable electric meters, single phase, complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron earth lead wire 4mm dia by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 32mm x 6mm size and protection pipe of 40 mm bore galvanised iron light grade.
XLPE insulated heavy duty electric power cables with multistranded cluminimum conductor, 1100 volts grade of size 25 sqmm 3.5 core complete all as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in hand/dense soil, complete all as directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm thick, complete all as directed by Engineer-in-Charge.
Removing of excavated soils to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.50mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I, laid before and after laying of cables, complete all as specified & directed by Engr-in-Charge.
Sub class 'B' bricks, old size, laid in trenches as cable covers complete, all as specified & directed by Engr-in-Charge.
GI pipe of size 40mm dia light grade, laid in trenches/walls including clamps, screws etc, complete all as specified and directed by Engr-in-Charge.
Replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar complete all specified and as directed by the Engineer-in-Charge. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing surface.
Supply and fix (in replacement) of MCB TPN 63 Amp (01 incoming + 4 outgoing) in complete all specified and as directed by the Engineer-in-Charge. Make: Havells cat part no DHMGCTNF040 or equivalent in Legrand/ABB.
Geyser (water storage heater) capacity of 25 Ltr complete including inlet and outlet connections, testing & commissioning, complete all as specified and directed by Engr-in-Charge.
Cutting, screwing, alterations and additions in existing GI pipe of size 15mm dia including clamps, screws etc. complete all as specified & directed by Engr-in-Charge. Note:-The disturbed surfaces will be made as per existing surfaces.
jatindera enterprises
surinder kumar jindal bros
Mahashakti Enterprises
M/S MADAN GOPAL and CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .