Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.0 LAccepted-Finance 171 GLOBEL SPACE HUDA GLOBEL SPACE COLONY 125055 | SIRSA | HARYANA | 125055 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹74.4 L+₹1.4 L (1.97%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹74.6 L+₹1.6 L (2.25%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest |
Tender Value
₹85.3 L
EMD Value
₹1.2 L
Closing Date
20 Sept 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer Jal Shakti Division Mandi
Providing, installation and maintain Real Time Water Quality Monitoring Station at Beas River Near STPs Raghunath Ka Padhar and Khaliyar Mandi Town Distt Mandi HP under JSV Division Mandi
2022_HPIPH_64906_1
9622-71MND
Open Tender
Civil Works
Item Rate
365 days
Mandi Town
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
EE Mandi
₹1.2 L
Yes
8 Jun 2023
13 Sept 2022
21 Sept 2022
13 Sept 2022
20 Sept 2022
14 Sept 2022
Amount
Providing, installation/ fixing in position at site, successful commissioning & maintainance of real time water Quality Monitering system for pH, Dissolved Oxygen, BOD, Total Coliforms/Fecal Coliforms and Total Suspended Solids parameters by using single sonde with UV Fluorescence Technology. Sonde Should have internal battery , sonde should also have optional facility to measure Water Depth / Level and other parametres conductivity , Ammonia , nitrate etc. by connecting sensurs , Data Logger should have broadcom BCM- 2387 Chipset. 1.2 G Hz Cuad-core ARM Cortex - A 53802.11 b/g/n wireless LAN and bluetuth 4.11 ( Blue tuth classic and LE) or higher configuration , GSM / GPRS facilities to all line data to Himachal Pradesh Irrigation & Public Health Department's website. The system should have following sensors /probes suitably insttaled at site to the entire satisfaction of Engineer Incharge in all leads & lifts including carriage of material complete in all respect.Data Logger should have Broadcom BCM 2387 chip set. 1.2 GHz Quad-core ARM Cortax- A 53 802.11 b/g/n wireless LAN and bluetuth 4.11 ( blututh classic and LE ), GSM /GPRS facility to upload data to CPCB/SPCB Sonde should have optinal facility to measure Water Depth / Level and other parameters like Conductivity, Ammonia nitrate etc. by connecting Sensures. Communication options : RS-232,SDI-12, USB or bluetuth. 1.01 Multiprove;3.45 " diameter. For measureing ofTryptophan / BOD , Turbidity/ TTSS, Coliform Turbidity/ Total Suspended solids ( TSS) having specification as under ; Range;0-1000F nu/0-1000 mg/I Resolution : 4Digits Accuracy:3% of Reading Operating Temp.=-10°C to 60°C Operating Humidity = 5 to 95 % non condensing 1.02 pH Sensure with Refrence Electrode having following specifications; pH range 0-14 Units Resolution : 0.1 Accuracy :0.2 pH Probe should have separate refillable reference cell for long term stability Operating Temp. =-10° C to 60° C Operating Humidity = 5to 95 % non condensing (1No) 1.03 D.O Sensure ( Cable of 15 meter with SDI Converter) (1No) 1.04 CAL- Focal Coliform measurement having following specifications; Total Coliform/ Fecal Coliforms Range.>1count/100 ml Resulution.>1count/100 ml Accuracy.>1count/100 ml Operating temp. =-10° Cto 60° C Operating Humidity= 5to 95 % non condensing Total Coliform probe should be Typtophan sensor (1No) CAL BOD sensors having Specification as under; BOD Range : 0-200 mg/I Resulition: 0.01 mg/I Accuracy:<5% of Reading Operating Temp.=(-) 10° C to 60° C Operating Humidity =5 to 95% non condensing BOD probe should be Tryptophan sensor (1No) 2. Data logging software & uploading system having Broadcom BCM-2387 chipset. 1.2 GHz Quad- Core ARM Cortex - A 53 802.11 b/g/n Wireless LAN and Bluetooth 4.1 ( Bluetuth Classic and LE) or higher configuration, GSM/GPRS Facility to upload data to JS Departments website. (1No) 2.01 All the times (1to 6) will be covered under 2 years comprehensive warranty period after successful installation with maintainance and replacement of spare parts ( if required) will be free of cost. 3. Annual Maintainance Contract of all the above items / system for five years after completion of warranty period i.e 2 years @ 5 % per year of estimated cost as: 1. Ist year 5 % 2. 2nd year 5 % 3. 3rd year 5 % 4. 4th year 5 % 5. 5th year 5 % ( 5 years) 4. Provision for fancing for guarding the system, alternate solar power supply system and sinking pipes for sensors including the cost of water proof enclosure for Data Logger & other sensitive instruments etc, all hardware installatio at remote station and their setup complete inall respect. in all leads and lifts to the entire satisfaction of Engineer InCharge.
Saurabh Vasudeva
P C Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .