Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.0 LAccepted-Finance NOT AVAILABLE | NEW DELHI | DELHI | 110001 | 1 | Accepted-Finance Accepted | |
| 2 | 2₹10.2 L+₹20,539.90 (2.05%)Rejected-Finance M S ASHAPURI INFRACON PVT LTD VILLAGE AND PO HURLA TEHSIL BHUNTER DISTT KULLU H P | 2 | Rejected-Finance Being a 2nd lowest |
Tender Value
₹6.1 L
EMD Value
₹13,000
Closing Date
13 Nov 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE Manali HP PWD Division Manali at Katrian
EE Manali HP PWD Division Manali at Katrian
C O Pangan Shangchar road Km 0 0 to 7 155 SH C O Missing Culvert 3 mtr RCC slab at RD 2 750
2020_PWD_42117_1
C/O Pangan Shangchar road Km. 0/0 to 7/155
Open Tender
Civil Works
Item Rate
90 days
manali
C O Pangan Shangchar road Km 0 0 to 7 155 SH C O Missing Culvert 3 mtr RCC slab at RD 2 750
5 documents required · 5 mandatory
₹350
EE Manali HP PWD Division Manali at Katrian
₹13,000
27 Nov 2020
3 Nov 2020
16 Nov 2020
3 Nov 2020
13 Nov 2020
3 Nov 2020
120 days
Amount
Excavation in soil in Hilly Area by manual means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto any leads as per drawing and Technical Specification Clause 1603.1 all kind of soil within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Earth work in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto any lead ,dressing of sides and bottom and backfilling in trenches with excavated suitable material within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications clause 802, 803,1202 and 1203 PCC grade M-10 (M-Ten) nominal mix 1:3:6(One cement : Three sand : Six graded stone aggregate ) within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications clause 702,704,1202 and 1203 in cement mortar 1: 5 (One cement : Five sand ) within all leads and lift of materials and as per direction of Engineer- in-charge.
Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification clause 1204.3.8 Granular material. within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Providing and laying cement concrete wearing course M 30 (M-Thirty ) grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 within all leads and lift including carriage of materials and as per direction of Engineer-in- charge. R.C.C M 25 ( M-Twenty five ) 1:1.5:3 ( One cement; one point five sand ; three graded stone aggregate )
Construction of R.C.C. railing of M 25 (M- Twenty five) grade in cast-in-situ with 20 mm ( Twenty millimetres ) nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm ( Two thousand millimetres ) as per drawing and technical specifications Clauses 800, 900 and 1208.3 within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
Drainage spouts complete as per drawing and technical specifications Clause 1209 within all leads and lift including carriage of materials and as per direction of Engineer-in- charge.
YASH PAL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .