| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC 23A 1 SHAKTI VIHAR TANKI ROAD BADARPUR NEW DELHI 110 044 | SOUTH EAST | DELHI | 110044 | L1 | Accepted-AOC Rate quoted by bidder found lowest and reasonable | |
| 2 | L2₹11.0 L+₹25,695 (2.39%)Rejected-Finance | L2 | Rejected-Finance Rate quoted by bidder found higher than L1 bidder |
Tender Value
Refer Docs
EMD Value
₹21,780
Closing Date
7 Jan 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Estate Manager
Estate Manager, EMU R and D Estate, Sanchar Vihar, Dehradun
Repair Maintenance of Heating Plant, Geysers n Allied Works at ITM Mussoorie.
2021_DRDO_660643_3
EMU/DDN/39/HEAT/01/ITM/21-22
Limited
Miscellaneous Works
Works
180 days
Mussoorie
As per NIT
6 documents required · 6 mandatory
₹500
Yes
Estate Manager, EMU R and D Estate, Sanchar Vihar
₹21,780
Yes
18 Jan 2022
24 Dec 2021
10 Jan 2022
24 Dec 2021
7 Jan 2022
25 Dec 2021
90 days
Amount
Taking down unsv electric storage water heater (Geyser) from existing position by disconnecting electric connection, inlet & outlet connections, shifting at workshop or repair at site, opening the same and repair/replacement of the unserviceable spare parts and re-assemble, shifting at site and reinstallation at existing place, making all connections and testing complete all as specified and as directed by Engineer in Charge at site. (Note: Replacement of spare parts shall be measured and paid separately.)
Supply only outer tank of the storage water heater of capacity 25 ltrs, vertical type made out of MS sheets for any make complete all as directed by Engr-in-Charge.
Supply only inner tank made out of copper of storage water heater vertical type of capacity 25 ltrs of any make complete all as directed by Engr-in-charge.
Supply only insulating material glass wool.
M&L for painting to the outer body of the storage water heater, vertical type of capacity 25 ltrs by applying one coat of synthetic enamel paint after preparation of the outer surface.
M&L for replacement of unserviceable heating element of rating 1.5 KW of water heater vertical/horizontal type of any capacity.
M&L for replacement of unsv thermostat of storage water heater vertical/horizontal type of capacity 20 to 25 liters.
M&L for replacement of unsv PVC connection 450 mm of inlet/outlet of storage water heater vertical/horizontal type of any capacity including 2 Nos brass nuts alongwith washers
M&L for replacement of unsv CP connections of storage water heater vertical/horizontal type of any capacity including brass nuts alongwith washers.
M&L for replacement of unsv indicator lamp red/green of storage water heater vertical/horizontal type.
Taking down carefully high-wall hot water fan coil unit of capacity 1.5 TR/600 K Cal/ hr- 800 Kcal/ hr and descaling copper coils and cleaning of all accessories of fan coil unit and refixing properly at existing place including welding/soldering as required at site and testing complete all as directed by Engineer in Charge, including making good the disturbed surface to match the existing surface.
Supply & replacement of MS pipe 50 mm dia on wall surface/ recess mounted in existing heating plant hot water outlet & inlet piping system including necessary cutting, welding, soldering and fittings i.e. bend, tee etc as required at site. Providing insulation with resin bonded fiber glass wool mattresses, aluminium foil cladding etc all as required at site complete including making good the disturbed surface to match the existing surface. Make of pipe: TATA/Jindal.
All as per item ser No 1.12 here in before but size of pipe 25 mm dia.
All as per item ser No 1.12 here in before but size of pipe 20 mm dia.
Supply & fix MS flange in 50 mm dia MS hot water pipe line of suitable thickness including welding of flanges and fixing gasket, nut, bolts etc as required at site and as directed by Engr-in-charge including making good the disturbed surface to match the existing surface.
Providing insulation all round hot water pipe of 80 mm dia with resin bonded fiber glass wool mattresses, aluminium foil cladding etc all as required & directed, complete including making good the disturbed surface to match the existing surface.
Providing insulation all round hot water pipe of 50 mm dia with resin bonded fibre glass wool mattresses, aluminium foil cladding etc all as required at site complete including making good the disturbed surface to match the existing surface.
Providing insulation all round hot water pipe of 25 mm dia with resin bonded fiber glass wool mattresses, aluminium foil cladding etc all as required at site complete including making good the disturbed surface to match the existing surface.
Providing insulation all round hot water pipe of 20 mm dia with resin bonded fiber glass wool mattresses, aluminium foil cladding etc all as required at site complete including making good the disturbed surface to match the existing surface.
Supply & connecting inlet and outlet copper pipe size 5/8 " dia to indoor hot water fan coil unit including suitable size of nut, brasing/ soldering complete all as required at site.
Supply & replacement of brass ball valve 50 mm dia Make: Zoloto/ RB Leader / Pryag /Equiv.
Supply & replacement of brass ball valve 20 mm dia Make: Zoloto/ RB Leader / Pryag /Equiv.
Supply & replacement of gun metal 'Y' stainer size 20 mm dia Make: Zoloto/ RB Leader / Pryag /Equiv.
Supply & replacement of brass ball valve 15 mm dia Make: Zoloto/ RB Leader / Pryag /Equiv.
Supply & replacement of ball valve 15 mm dia gun metal 'Y' stainer Make: Zoloto/ RB Leader / Pryag /Equiv.
Supply & replacement of gun metal butter fly valve 80 mm dia from existing hot water MS pipe line including necessary gasket, nut & bolts complete. Make: Zoloto/ Leader / Audco India /Equiv.
Supply and replacement of motor of blower from High-wall fancoil unit, capacity 1.5 TR. of existing make.
Taking out old unsv contactor from existing panel and supply and fix power contactor 400 amps 3 pole ( MNX400) of make L&T making all electric connections and testing complete all as specified and directed.
Taking out old unsv starter from existing panel board of heating plant and supply and fix new starter of capacity 7HP to 10 HP 3 phase 415 amps, making all electric connections and testing complete all as specified and directed
Material and labour for replacement of change over switch 100 amps 4 pole 415 volts of make Havells/ Scheinder / C&S
CLYMATE CONTROL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .