| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.0 L+₹41,009 (1.49%)Rejected-Finance NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L2 | Rejected-Finance L2 | |
| 3 | L3₹29.7 L+₹2.1 L (7.76%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L3 | Rejected-Finance L3 |
Tender Value
₹29.5 L
EMD Value
₹58,960
Closing Date
23 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVN OF STANDBY POWER SUPPLY AT MAIN GUARD ROOM AND ARMOURY OF HQ SWAC VSN CHILODA AND CERTAIN MINOR WORKS AT VSN, SEC-09 AND COMN FLT AREA UNDER GE (AF) CHILODA
2023_MES_577486_1
8887/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VSN
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹58,960
Yes
20 Mar 2023
27 Jan 2023
25 Feb 2023
27 Jan 2023
23 Feb 2023
10 Feb 2023
27 Jan 2023 - 9 Feb 2023
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and directed.
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and directed. Note: - Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc complete all as specified and directed.
Supply and laying reinforced precast concrete cable cover, class LV cover, Type I, flat, size 250mm x150mm x 40 MM complete all as specified and directed.
Returning, filling including spreding, leveling watering and well ramming in laying not exc. 25cm for soft/ loose soil complete all as specified and as directed.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/loose soil complete all as specified and as directed.
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 50 mm dia for cable protection complete all as specified and directed by Engineer In Charge.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and as directed. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and as directed. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and as directed. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and as directed. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and as directed. Note:- Excavation / earth work will be measured and paid separately.
M&L in trenches in road cross / floors of tube galvanished iron light grade 50 mm dia with all fittings for protection of cable complete all as specified and directed by Engr-in-Charge.
M&L in trenches in road cross / floors of tube galvanished iron light grade 40 mm dia with all fittings for protection of cable complete all as specified and directed by Engr-in-Charge.
Supply, install, testing and commissioning of outdoor type factory assembled diesel driven generating set with silent (acoustic) enclosure with fully wired alternator AC for ambient conditions at Mamun (at site) for 62.5 KVA continuous rating at 415 volts adjustable at ± 2.5% AC 3 phase, 0.8 power factor, 4 wire, 50 Hz ± 1 %, 1500 rpm directly coupled with suiitable capacity diesel engine liquid coolent based mounted on common base frame placed on & including PCC platform with floor mounted Fuel Tank of adequate capacity with fuel lines, anti vibration pads, standard control & AMF panels and other accessories etc complete all as specified & directed consisting of following;- (A) Prime Mover (Diesel Engine) : Adequate capacity diesel engine of standard design consisting of direct injection type, four stroke, liquid cooled technology conforming to BS 5514 and IS 10000 suitable for prime duty generating set of minimum 87.5 BHP @ 1500 RPM with multi cylinders to drive independently alternator and considering derating as per site condition after generating and reducing power consumed by accessories, directly coupled through coupling having overload capacity of 10% for one hour in every 12 Hrs continuous running mounted on base frame with following sailent features and standard accessories for safe handling & operation of engine as under:- (a) The gen set should have capacity to run continously in variable load condition for unlimited hours and should also have a 110% load capacity of 01 hour in every 12 hours of operation.
(b) Air System - Inlet & Exhaust comprising (i) Dry-type paper element air Cleaner (ii) Restriction Indicator / Vacuum Indicator (iii) Intake Manifold (iv) Exhaust Manifold (v) Silencer muffler and (vi) Stainless steel Exhaust Flexible coupling (c) Cooling System comprising (i) Radiator to suit ambient conditions (ii) Cooling system piping (iii) Thermostat (iv) Pressure cap (v) Coolant Inhibitor and (vi) Engine Driven Fan. (d) Fuel System comprising (i) Fuel pump -Low pressure type (ii) Injectors (iii) Cartridge paper filters primary and secondary for Fuel. (e) Governor :- Mechanical Governor for A1 governing of engine speed from No load to full load. (f) Lub Oil System :- (i) Plate Type lub oil cooler (ii) filters-lubrication oil (g) Fuel Tank :- Draw out type integral fuel tank made of MS sheet (duly painted) of capacity min 100 ltrs or as recommended by manufacturer with level indicator in ltrs, provided with drain plug and air vent / breather and inlet and outlet connection (h) Electric Starting system comprising (i) Electrical starter - 12 Volts (ii) Engine driven battery charging alternator (iii) Cut Out and (iv) One No of 12 volts of 120 AH maintenance free battery with suitable connection terminals and leads for proper battery connection
(j) Engine Monitoring, Protection and Diagnostics relay suitable to display following (i) Lub oil Pressure (ii) Coolant Temperature (iii) Engine Speed (iv) Hours Run (v) Battery Voltage, Battery charging voltage (vi) Fuel level in percentage, (vii) AC Voltage 3 phase (viii) Current RYB 3 phase (ix) Power Factor (x) Frequency (xi) KVA (xii) Kilowatt (xiii) KWH with suitable rated CTsand suitable for (i) Start and Stop (ii) Common Shutdown (iii) High coolant temp warning and shutdown (iv) Lub oil pressure warning and shutdown (v) Low fuel level shutdown (vi) Overspeed shutdown (vii) Alternator Protection including over voltage, under voltage, over and under frequency, Over current”. (k) Misc Accessories i.e - (i) Flywheel Housing (ii) Flywheel (iii) Anti-vibration pads (iv) Emergency stop push button etc all as required for smooth operation of DG set as recommended by manufactrurer. (B) ALTERNATOR :- Self excited, self regulated screen protected drip proof type with Class 'H' Insulation Salient pole revolving field and electronic Automatic Voltage Regulator for voltage regulation of ± 0.5% from No load to full load, standard enclosure 415 Volt 50 HZ 4 pole 62.5 KVA continous rating capacity etc complete as per IS-13364-2 and conf to IS-4722 or BS 2613-1970 all as required or recommended by manufactrurer. (C) AMF PANEL:- AMF Panel auto start with suitable capacity changeover, AMF shall be suitable for two incoming (DG Set & Commercial supply) and one out going with suitable capacity of MCCBs 4 pole power contactor, AVF Meter, KWH Meter, Volt/Ammeter, AMF Relay, CTs, Indicators, auto battery charger.
(D) BASE FRAME : Made of ISMC fabricated and welded construction channel duly painted for mounting Engine and Alternator all as per manufacturer's design along with specially designed in built vibration pads. (E) Acoustic Enclosure (CANOPY) :- Shall conform to Central Pollution Control Board (CPCB) norms of 75 dBA at one metre under free field conditions, having air inlet louvers specially designed to operate at rated load even at ambient conditions on air inlet temperature,powder coated for long lasting service life and superior finish with UV resistant powder coating to with stand extreme environments, designed to have minimum ease for unloading & shifting , i.e with central lifting facility, rust free hardware made of stainless steel, Insulation material to meet IS:8183 specifications. (E) Foundation :-PCC platform of size and type as specified in PS for mounting of DG Set. (F) POL for testing and first fill of engine oil as required after commissioning. (G) Spares and tools as specified in PS.
Out going :- a) MCCB 4 Pole, current rating 63 Amp, With Thermal Magnetic release , breaking capacity 25 kA at 415V, 50Hz - 03 Nos. b) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No. c) M & L for necessary excavation and as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
M & L for Earthing complete in repairs with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as eGI strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order. (ii) necessary excavation wk is included in this item.
M & L chemical Earthing complete with copper plate electrode (98 percent conductivity when annealed) 900mm x 600 mm x 5 mm thick buried directly in groound (Earth pit not less than 4.0 meters deep below normal ground level and 1.3 mtr wide) with top edge of the plate not less than 1.5 mtr below ground level earth plate connected to copper strip (98 percent conductivity when annealed) 32 x6 mm (drawn in and including earth lead protection pipe light grade GI OF size 50 mm dia ) by means brazing at both edges with vertical plane of electrode all as shown in plate No 2 of SSR Part I connected to earthing lead, filling with Charcoal 400 KG, dust and common salt 325 KG and Magnesium sulphate 100 KG, necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade PCC Chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 type B1, 550 x 550x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 nos of handles of 10 mm dia steel rod 500 mm long all as specified and directed and testing on completion and connected to equipment with lugs and connected to equipment with lugs and screw nuts etc complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired resistance in not obtained the earthing will be redone at no extra cost.
Supply and fix in replacement of copper strip of existing size 32 x 6 mm with saddles and fixing screws etc for earthing connection to bus bar trunking system of existing LT Panels etc complete all as specified and directed by Engr-in-Charge.
Supply & fix Exhaust Fans AC single phase 230/ 240 V of size 300 mm sweep with louver heavy duty Complete all as specified and directed by Eng-In-Charge. Note :- (a) Making hole in existing brick/PCC wall of required size to accommodate exhaust fan and fixing louvers on outer surface shall be deemed to be inclusive of quoted rate by the contractor. (b) Making good with the existing surface of the wall with matching colour of white wash or distemper in included in the scope of work.
Supply & fixing ceiling fan 1200 mm sweep complete with blade, canopy and down rod and connecting up to and including provision of flexible three core copper conductor cable 23/0.0076 from ceiling rose to connector block complete all as specified and as directed.
Supply & fix Wall Mounted fan AC single phase 230/ 240 V of size 400 mm sweep with remote complete all as specified and as directed.
M&L for point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through metallic rigid / PVC heavy duty concealed conduit/ casing capping/open coduit with 1.5 sqmm, single core, PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box as required size at site incl all connected accessories , box made from not less than 1.6mm GI sheet factory made complete all as specified and directed by Eng-In-Charge for the following. (a) One fan point controlled by one switch complete.
(b) All as per item No 24 here in before but One 3 pin socket out let 5 Amps on the independent board.
S&F Modular switch one way 6A, 1 Module, complete all as specified and directed by Eng-In-Charge.
S&F Modular socket 6/10A-2/3 pin combined 2 Module complete all as specified and directed by Eng-In-Charge.
S&F white cover plate with frame , 3 module complete all as specified and directed by Eng-In-Charge.
S&F fan regulator step type suitable for ceiling fans, prewired 230 Volts, AC, 50 Hz supply 60/ 100 Watt complete all as specified and as directed.
S & F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed by Eng-In-Charge.
Supply, install high wall split type air conditioner unit indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for batter indoor air quality and EER 3.2 of cap 1.5 ton inverter type 5 star complete all as specified and directed by Eng-In-Charge. (Note: Rate of Extra copper pipe and drain pipe should be included in quoted rate and will not be paid extra)
M&L for concealed sub main wiring complete with PVC insulated FRLS cable of single core 04 Sqmm 1100 volts grade with multi standard copper conductor for drawn through and including conduiting PVC casing capping with accessories incl 4 Sqmm unsheathed multi standard FRLS copper conductor as earth wire. Note: Two runs of cable and one run of conduit & earth wire shall be measured as one run length complete all as specified and directed by Eng-In-Charge.
S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed by Engr-in-Charge.
BK CONSTRUCTION
MONA GENERATOR SEVICES PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .