| 1 | L1₹39.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹44.1 L+₹4.5 L (11.4%)Rejected-Finance C 488 SC PLOT NO 10 EKTA NAGAR NEAR ANANT LEWIS PUBLIC SCHOOL BANAR ROAD NANDRI PO SARAN NAGAR JODHPUR 342015 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹44.3 L+₹4.8 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹45.3 L+₹5.7 L (14.5%)Rejected-Finance 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹46.3 L+₹6.8 L (17.1%)Rejected-Finance 338 PRABHAT NAGAR NANDRI BANAR ROAD JODHPUR 342001 JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
24 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE ARMY CENTRAL MULTAN LINES ARMY AREA JODHPUR
ADDN ALTN TO BLDG NO 109 111 PROVN OF HARD STANDING FOR VEH COMING FOR FOL COLLECTION NEAR E M STORES AND OTHER SANCTIONED WORKS UNDER AGE B R II OF GE ARMY CENTRAL ARMY AREA JODHPUR
2022_MES_549609_3
GE/J/A OF 2022-23 (9135/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹92,000
Yes
4 Nov 2022
4 Oct 2022
26 Oct 2022
4 Oct 2022
24 Oct 2022
10 Oct 2022
Amount
Note:- (i) All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Replacement/Renewal" unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are requested to quote their rates accordingly.
B/R WORK Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed .
M&L for 75 mm thick PCC 1:4:8, type D-2 by (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed.
Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed.
Supply and laying machine / factory made kerb stone of M-25 grade,at or near ground level, cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
Rolled mild steel sections and running rails and guides for sliding doors as in main and cross beams, hip and jack rafters, purlins where connected to common rafters, fixed with angle cleats or other connecting plate etc., conforming to Fe 410 W Gde- E- 250) quality- A, complete all as specified and as directed.
M&L for squared rubble stone walling, Jodhpur type, regular coursed, well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed.
Extra over square rubble stone walling, Jodhpur type, regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and as directed.
Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed by Engineer-in-charge.
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in coping/ benching, DPC, pier caps, bed blocks, for hold fast etc., including mixing with WPC and necessary form work, complete all as specified and as directed by Engr-in-Charge. Note:- WPC shall be measured and paid separately.
M&L for 150mm thick (compacted thickness) WBM in two layers, each layer 75mm thick (compacted thickness) with coarse stone aggregate of grading 2 (63 to 40mm size spread & rolled with 8 to12 tonne power roller, rolled and consolidated to required gradient and camber all as specified. Note: The unit rate inserted is for two layers of WBM (75mm compacted thick each layer) measured as one unit, each layer laid and compacted separately. The SSR provisions shall be deemed to have modified accordingly.
M&L for 200 mm thickness Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber, watered and rolled, rammed to a true surface with 8 to 10 tonne power roller, complete all as specified and as directed.
M&L for 15 mm thick sand cushioning for QCC over WBM surface including watering and consolidation, complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring,path , foundation etc complete all as specified and directed.
M&L for ready mix cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, including polythene film, transportation, placing, compaction, trowlling & etc., complete all as specified and directed by Engineer-in-charge. Note:- The rates include for (i) Use and waste of side form for laying pavement concrete / hard-standing in bays between joints & Contraction expansion joint/or between the two contraction joints for thickness of pavement upto and including 25 cm.
Forming Contraction (Dummy) joints 50mm deep x 12mm wide, filled with sealing compound of grade 'A', complete all as specified & as directed.
Forming 12mm thick expansion joints in traverse direction to the road at spacing of 45 m ( after 10 Nos. contraction joints) filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, suitable for 150 mm thickness of concrete slab, complete all as specified & as directed.
Brushing neat cement slurry with 3.0kg of cement per sq. metre, complete all as specified & as directed.
M&L for prepainted Galvalume Aluminium Zinc Coating GI based corrugated Steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws including dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and as directed .
M&L for framed work as hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc., wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and as directed by Engr-in-Charge.
M&L for rolled mild steel confirming Fe-410-W (Gde E-250), quality A, in door or gates of angle or other section with gusset plate, rail braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclding of steel, sheeting or other covering ) and hanging also fastening and fixing complete all as specified and as directed.
M&L for machine cut kota stone slab 18 to 20mm thick as in flooring/skirting, cooking plateform, laid and jointed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in CM 1:4, complete all as specified and as directed.
M&L forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for100mm thick slab, complete all as specified and directed.
M&L for forming contraction (Dummy) joints 65mm deep x 12mm wide filled with sealing compound grade 'A' including necessary form work complete all as specified and as directed.
M&L wearproof topping, 30mm thick as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (including metallic hardner) of approved quality/ make, complete al as specified and as directed by Engr-in-Charge
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F factory made box type windows (steel) (BWM) with side hung shutter as shown in Drg No CEJZ/TD/20 sheet1/3 to 3/3 complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engr-in-Charge. Note : Both shutter (wherever applicable) will be jointed internally with flat iron of size 40 x 4mm and quoted rate deemed to include the cost component of the same.
S&F rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars barred iron doors; chowkhat, doors with MS sheet, ladders ;framed balusters walk ways railings framed work of water tanks and similar work conforming to Fe-290Gde E-165 complete all as specified & directed by Engineer-in-charge
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and apply two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth including & over a coat of pink primer including preparation of surfaces, complete all as specified and as directed.
S&F factory made flush shutters 35 mm thick, solid core construction, with block board and plywood face panels, both faces is covered with decorative face veneer with lipping/frame to match with moisture content not less than 12% as per IS. The face panel comprising of ply wood or cross band and face veneers shall be glued by hot pressed process, complete all mortic lock and handel arremgment, complete all as specified and as directed.
S&F of mild steel butt hinges medium weight, cold rolled of size 100 mm size, complete all as specified and as directed by Engr-in-Charge.
S&F Mild steel pressed handles 150mm size, oval type, stove enamelled black, pattern and design, complete all as specified and as directed by Engr-in-Charge.
S&F of mild steel barrel tower bolt 200 mm long stove enamelled black with bright bolt, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
Demolition of brick work/stone masonary built in cement mortar including all quoins, pillars, etc., removal of unserviceable materials, debris, rubbish to outside MD land, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings not exc. 15 cm thickness, below or above ground level) and removing debris out of MD land, complete all as specified and as directed.
M&L for 18-20mm thick machine cut Udaipur green marble, (size & shape, shade and pattern as approved by GE) as in cooking platform including & over 10mm thick screed bed in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including polishing and rounding the edges, complete all as specified and as directed.
S&F of galvanised iron steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm with tinned tacks or GI staples & necessary fitting on steel/ wooden surface, complete all as specified and as directed.
S&F 3mm thick plain sheet glass ordinary quality & glazing with oil putty in square not exc 0.50sqm in each pane, complete all as specified and as directed by Engr-in-Charge.
S&F of mild steel sliding door bolt 300 mm long stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on stapple plate, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully cement conc /spalled out concrete from RCC roof projections, ceiling ,sunsheds, beams, etc upto cover depth by chipping out lightly including necessary scafolding etc, complete all as directed by Engr-in-Charge.
M&L for 15 mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface, complete all as specified and as directed.
M&L Rendering 10 mm thick in CM 1:3 on concrete surfaces on ceiling / facia /RCC Chhaja etc all as directed & finished even & smooth complete
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint of approved quality & tint, over & including one coat of chalk white, complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces and applying two coats wall care putty (2mm each layer) including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound emulsion paint on walls, complete all as specified and as directed. Note:- OBD shall be in one or more colours/ shades all as approved by GE.
M&L for Flush pointing to stone slab joints Jodhpur type regular course in CM 1:3, complete all as specified and as directed.
GI frame work size of grid 605 x 605mm for seamless ceiling comprising of GI perimeter chanel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and inccluding ceiling section (not exceeding 1.2M length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel at 457mm c/c and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and including providing gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions over the frame work and preparation of ceiling board and applying two coats of oil bound distemper over a coat of 'Birla' wall / ceiling care putty including dismantling of existing false ceiling of any thickness with cover fillets complete all as specified and as directed.
M&L for carrying out roof treatment work in the following stages :- (a) Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces, over and including 10 mm thick cement mortoar (1:4) and surfaces finished even and smooth without using extra cement all as specified . (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 20 micron HMHDPE, outer film 20 micron each, thickness 1.50 mm having weight not less than 2.25 Kg/Sqm using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen confirming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. (e) FIFTH COURSE:- 40 mm thick plain cement concrete 1:2:4 B0-type using 12.50 mm stone graded crushed aggregate. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item. 3. Work of roof treatment shall be carried out by authorize applicator of APP manufracturer.
M&L for plain mild steel sheet 0.63 mm thick having zinc coating of 275 grade, as in ridge, valley gutters, hip etc., length & girth as fixed with self tapping screws all as specified and as directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate), as in sub base of flooring etc., incld finishing the surface even & rough to receive tile, complete all as specified and as directed.
Taking down of steel window and ventilators, complete all as directed by Engr-in-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per TD and the directions of Engineer-in-Charge. Note : (i) Hinges, handles etc shall be measured and paid separately. (ii) Glass pan and rubber beading shall be measured and paid separately.
S&F for 4.80 mm thick plain glass, exc 0.50 Sqm each pane ordinary quality & glazing, complete all as specified and as directed.
S&F powder coated anodised aluminium deco grill as per sample fixed to aluminium frame work of windows & ventilators, complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm with necessary fitting on steel/ wooden surface, complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and as directed.
M&L for 15-18 mm thick (telephone black shade) granite stone, as in cooking plateform, & similar work, machine cut, mirror polished best quality as per sample, including & over 15 mm thick screeding in CM1:4 including rounding of the edges & providing suitable dia hole in the slab for the gas pipe, complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces and applying two coats wall care putty (2mm each layer) including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of plastic emulsion paint on walls, complete all as specified and as directed. Note:- Paint shall be in one or more colours/ shades all as approved by GE.
Excavation in post holes (or similar holes each not exc 0.50 cum) getting out, returning and filling in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Plain Cement concrete 1:3:6 type C-2 by using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, etc., complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square head and one end screwed or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but not exc 10cm long, complete all as specified and as directed by Engr-in-Charge.
S & F Fibre glass reinforced translucent 2 mm thick corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof ,wall etc complete all as specified and as directed.
M&L for preparation of the new surfaces of steel & applying two coats of synthetic enamel paint over one coat of red oxide primer over 10cm width or girth, color match with chainlink color, complete all as specified and as directed by Engr-in-Charge.
M&L Prepainted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws, complete all as specified and as directed by Engr-in-Charge.
E/M WORK Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces, complete all as directed.
Taking down DB with MCB any type/any size & single pole and neutral enclosure with two pin and earth plug with MCB/MCCB/ including all connecting accessories, complete all as directed.
Taking down existing old sub main wiring of any size and make, complete all as directed
M&L point wiring using approved colour coding as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI marked, in and including heavy duty non metallic PVC rigid conduit of 20mm dia with accessories concealed in wall/roof/ or surface on floor/ceiling etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) with 3 mm thick plastic laminated sheet (ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & unsheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and as directed.
All as per serial Item No. 69.00 above but for one 3 pin socket outlet 5/6 Amps on the independent board, complete all as specified and as directed.
All as per serial Item No. 69.00 above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and as directed.
All as per serial Item No. 69.00 above but for 16 Amps 6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLSH multi-stranded copper conductor with 4.00 Sqmm PVC insulated & FRLSH multi-stranded copper conductor as earth wire complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 5 Amps, 230 Volts, ISI Marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15 Amps, 230 Volts,ISI Marked, complete all as specified and as directed.
S&F lamp holder insulated body polycarbonate type with back plate with 9W LED lamp, complete all as specified and as directed by Engr-in-Charge.
S&F socket outlet, flush type, single pole, 2 in 1, 3 Pin, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed.
S&F socket outlet, flush type, single pole, 2 in 1, 6 Pin, 5/15 Amps, 230 Volts,ISI Marked, complete all as specified and as directed.
S&F in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down old u/s material complete all as specified and as directed. Make : Bajaj Cat No. BCLSB 20 WH or Equivalent in Philips/ Havells as approved by GE.
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated body, ISI Marked, complete all as specified and as directed.
S&F Electronic fan regulator, 120W, modular type, 2 module and connecting electrically, ISI Marked, complete all as specified and as directed by Engr-in-Charge.
Taking down and refixing / Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan including filling cavities with filler, one coat after cleaning all dust etc., complete all as directed.
S&F bldg security LED Light Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 32mm dia bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and as directed. Make : Philips/ Bajaj/ Havells
S&F MCB single pole and neutral 240 volts 63 Amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB single pole 230 volts rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SPN 230 volts rating from 40 to 63 amps, with rupturing capacity 10 KA, 'C' curve type, with over load and short circuit protection, complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F Prewired distribution board in sheet metal with 200 Amps rated copper bus bar Confirming to relevant IS.SPN 8 way, double door, 240 V for fixing MCB's, IP 43 protection, complete all as specified & directed by Engg.-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface. Make : Legrand/ ABB/ Schneider
S&F Prewired distribution board in sheet metal with 200 Amps rated copper bus bar Confirming to relevant IS.SPN 4 way, double door, 240 V for fixing MCB's, IP 43 protection, complete all as specified & directed by Engg.-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface. Make : Legrand/ ABB/ Schneider
S&F for in replacement of sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 4.00 Sqmm and one run of 4.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 4.00 sqmm cable with one run of 4.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron earth lead wire of size 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and laying in trenches or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core in service connections, as in replacement, including taking down old u/s cable, complete all as specified and as directed.
Excavating in trenches in any type of soil, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc not exc. 10 Sqm on plan and not exc 1.5 m in depth and getting out, complete all as specified and as directed.
Returning filling in including spreading ,levelling,watering and well ramming in layers not exc 25cm, complete all as specified and as directed.
Removing excavated material at a level not exc 1.5 m above the starting point, complete all as specified and as directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer, complete all as specified and as directed by Engg.-in-charge. Note :- Punned thickness shall only be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 300x180mm x40 mm, complete all as specified and as directed.
M&L road cutting as 0.45 m wide and 0.60 m in depth for laying LT UG cable and making distrubed surface by PCC 1:4:8 type D-2, (using 40 mm graded stone aggregate), complete all as spcified and as directed by Engg.-in-charge.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore, complete all as specified and as directed. Make : Prakash/ Tata/ Jindal
NOTE:- (i)- Quantities are clubbed in BOQ for different Jobs. For which ref. Annexure-I on Sl. page. No. 30 to 31 of tender document. (ii)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
SNEH CORPORATION
JB INFRA
RISING ELECTRICALS
Bhairav Infra Projects
M/s Ajay kumar Garge
Rajesh Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .