| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.7 LAccepted-AOC SINI BHAVAN VILLOOR VETTIKKAVALA P O | KERALA | ₹6.7 L | 1 | Accepted-AOC L1 |
| 2 | 2₹7.5 LRejected-AOC | ₹7.5 L | 2 | Rejected-AOC L2 |
| 3 | 3₹7.8 LRejected-Finance JITHIN BHAVAN ALAKKUZHI THALAVOOR KURA P O | KERALA | ₹7.8 L | 3 | Rejected-Finance Third lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical The documents submitted as proof of experience are insufficient. |
Updated dates
Tender Value
₹9.2 L
EMD Value
₹22,900
Closing Date
6 Mar 2026, 4:00 pmClosed
AEE, ESD Kottarakkara
ESD Kottarakkara, Vydyuthi Bhavanam, Kottarakkara
Reconductoring with LT ABC and rabbit conductor under Kokkad Exchange Transformer
2026_KSEB_836489_1
TENDER/2025-26/4233/16
Open Tender
Electrical Works
60 days
Kokkad
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,242
₹22,900
16 Apr 2026
18 Feb 2026
11 Mar 2026
18 Feb 2026
6 Mar 2026
18 Feb 2026
18 Feb 2026 - 25 Feb 2026
Fitting one Additional 75x40mm, 1.8m channel cross arm in existing single pole incl. conveyance of materials
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit
Providing Stay for LT poles incl. digging & back filling pit.
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt&nut etc
Erection of Anchor clamp / dead end clamp for LT ABC of any size
Providing Cable Tie
Providing End Caps
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm
Installing One No. 4 way Satellite Connector of size Main :16 to 95, Tap:4 to 35 Sq.mm to the LT AB cable of Standard size
Erection of suspension clamp for LT ABC of any size
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
Installation of Pre-insulated straight through joints for 16sqmm cable
Installation of Pre-insulated straight through joints for 70sqmm cable
Installation of Pre-insulated straight through joints for 50sqmm cable
Renewal of existing damaged/broken old LT stay with existing stay rod.
Additional rate for excavation of one Pit for LT Pole/LT Stay in Laterite.
Straightening one Slanted LT pole after unbinding the line and rebinding the line after work.
Reconductoring one km LT Sph 2 wire OH old line with new ACSR Rabbit conductor incl. conveyance of materials.
Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion
Insertion of one LT PSC pole in existing Sph OH line incl. digging & back filling pit, fitting cross arm, insulator, binding etc.
Renewal of existing damaged/old LT stay with new stay in place and refitting of all items and conveyance of all materials.
Renewal of existing damaged/old LT PSC/RCC (Sph line) pole with new PSC pole in place and refitting of all items incl. conveyance (except pole)
Renewal of existing damaged/broken old 11kV Stay to the existing stay rod.
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials
Renewal of existing damaged/old 11kV Stay with new stay in place incl. excavation & backfilling of pit and conveyance.
Renewal of existing damaged/old 11kV Fly stay with new Fly stay (excluding stay-pole & stay-rod) including conveyance.
Fitting and erecting one HT PSC Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads
Providing Strut using LT PSC pole incl. digging & back filling pit.
Renewal of existing damaged/old LT TW/RSJ/Rail (Sph line) pole with new PSC pole in place and refitting of all items incl. conveyance (except pole)
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap : 4-35 sqmm
Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite
Loading LT PSC pole from the stacking place and unloading the same at work site (transport by vehicle
Loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading
Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane
Stringing of 1.1 kV Aerial bunched cable of size 3 x 70 + 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles
Dismantling one LT 2 line cross arm from existing pole.
Fitting one LT 2 line cross arm on HT or LT existing poles incl. fitting insulators and binding the same with LT Line.
Renewal of existing damaged/old LT PSC/RCC (3ph line) pole with new PSC pole in place and refitting of all items incl. conveyance (except pole)
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole and reconnecting.
Fitting of one No. pole top service connection box of standard size (up to 4 way) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height excluding giving connections
Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling
Insertion of one HT PSC pole in existing line incl. digging & backfilling pit, fitting cross arm, insulators, binding etc
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_1408219.pdf
finsummary_1408219.pdf
aoc.pdf
finance_1408219.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
SpecKokkadExchange.pdf
Tender Documents • 0.34 MB
BOQ_1408219.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid