| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹30.5 L+₹52,900 (1.76%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹32.4 L+₹2.4 L (8.06%)Rejected-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹33.1 L+₹3.1 L (10.4%)Rejected-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹33.7 L+₹3.7 L (12.3%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-AOC REJECTED |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
10 Nov 2020, 6:00 pmClosed
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR/ MAINTENANCE OF ELECTRIC AND WATER SUPPLY INSTALLATIONS AND OTHER MISCELLANEOUS ITEMS AT ICGS VADINAR UNDER GE (I) CG PORBANDAR.
2020_MES_387253_1
8557
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ICGS VADINAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I CG Porbandar
₹56,000
Yes
6 Jan 2021
17 Oct 2020
11 Nov 2020
17 Oct 2020
10 Nov 2020
5 Nov 2020
Amount
SCHEDULE 'A'
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick , complete all as specified and directed by Engr-in-Charge.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point , complete all as specified and directed by Engr-in-Charge.
M&L Spreading and filling of dry sand cushioning to UG cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable to full width of trenches and punnned down to 18 cm complete all as specified. NOTE : Punned thickness shall only be measured and paid.
Labour only for laying unreinforced precast concrete cable cover , retrieved complete all as specified and directed by Engr-in-Charge.
Supply and laying only unreinforced precast concrete cable cover , class LV type1, flat size 250 mm x 150mm x 40 mm with ISI mark factory made , complete all as specified and directed by Engr-in-Charge. Make: Sukhi Enterprises (Sukhi)
Servicing of DG set ('C' Check) of Cap 100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolent top up. (e) Air filter Secondary (f) Air filter Primary (g) Engine Oil Make of DG set: Ashok Leyland Note: a) Defective parts if any other than listed at (a) to (d) above will be measured and paid separately b) The materials obtained while servicing of DG Set shall become the property of the contractor without any recovery of the same .The contractor shall Quote unit rate considering this aspect.
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.98 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge. Note: Defective parts if any will be measured and paid separately
Supply only items for APFC Panel a) Heavy duty gas filled Capacitor 10 KVAR,415V, 3phase, 50 Hz. Make: L&T/C&S/Siemens
b) 8 Steps APFC Relay Make: L&T/C&S/Siemens
Comprehensive maintenance of HT panel, detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized service centre of VCB manufacturer/OEM or skilled VCB repairing agency, re-insertion of trolly in HT panel, Testing for smooth , complete all as specified and directed by Engr-in-Charge. Note: Worn out parts shall be measured & paid separately under respective item.
Supply only parts/Items for HT Panel a) Numerical relay, for earth fault over current/short circuit, 24V/30V DC, operated and setting at site complete all as specified and as directed. Make : CG/L&T MC61C/AREVA
b) Motor Cut off Limit switch. Make: BCH/L&T/C&S
c) Closing Coil 24V DC Assembly
d) Shunt trip Coil 24 V DC
Cutting & removing existing joint and supply, jointing and testing outdoor type Heat hrinkable straight through cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade , complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON.
Cutting & removing existing joint and supply, jointing and testing indoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON
Servicing and testing of Split type air conditioners of capacity 1.5 ton/2.0 tr of any make complete by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, greasing of blower motor, checking and removing any vibration and leakage ensure cutting of compressor / heater in case of failure of blower motor, Gas charging and testing after fixing at site, complete all as specified and directed by Engr-in-Charge. Note: (a) Cost of any minor nature repair / items such as nuts ,bolts, washers, screws, rubber mounting pads of compressor etc and labour required for removing / refixing including transportation of equipment and repair of PCB is deemed to be included in the unit rate of this items. (b) Major items of spares / jobs, if any required while carrying out servicing will be measured under respective items of Schedule 'A' here in before.
Supply and fix in repair Unserviceable hermetic sealed rotary compressor with new compressor capacity not less than 19000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engr-in-Charge.. Make : Tecumseh/Toshiba
Supply and fix in repair Unserviceable hermetic sealed rotary compressor with new compressor capacity not less than 24000 BTU/hr single phase, including gas charging in the system, complete all as specified and directed by Engr-in-Charge Make : Tecumseh/Toshiba
M&L Rewinding of blower motor or condenser fan motor, replacement of wornout bushes, complete of split type air conditioner complete all as specified and directed by Engr-in-Charge. Note: Cutting of wornout wiring deemed to be included in unit rate
M&L Dehydration/Filteration of tranformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV complete all as specified and as directed by Engr-in-Charge.
Supply only Transformer oil having di-electric strength of not less than 50 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand)
Supply only Silica gel breather of capacity 11 KV Transformer 315 KVA , complete all as specified and directed by Engr-in-Charge.
Servicing of servo stabilizer oil cooled automatic type of capacity 30 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel level, supply system, Lubrication system, rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lubrication oil. (b) 3 phase Digital display system Make of Stabilizer : Vinitec -
Supply and fix in replacement Digital time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified Make :L&T/Hensel
M&L Preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and apply one coat of red oxide and applying two coats of aluminium paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm black base complete all as spd and as directed by Engineer-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed Make : Hensel Cat No.DK 2525 G or its equivalent in sintex/Legrand
M&L Bore of 150mm Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres long, connected with earthing lead of size 25mm x 4mm dia galvanisedstrip to the earth test point 9upto 7.5m length) including earth work, returning, filling, fill compound to reduce soil sensitivity and high quality earth pit cover made of polymer all as specified and directed by Engr-in-Charge. Note:- The compound (earth enhance gel) to reduce soil resistivity should be suitable for the prevailing soil, IR value should be less than 5.0 Ohm. Excavation, earthwork returning and filling to be included in the quoted rate
Material & Labour Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of following sizes-Make-Denson/Siemen, , complete all as specified and directed by Engr-in-Charge. a) 25 sq mm to 50 sq mm
b) 70 sq mm to 150 sqmm
Taking out UNSV LT UG cables of any sizes from trenches ,retrieving of cover and stacking for reuse, complete all as specified and directed by Engr-in-Charge.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area complete all as specified and directed by Engr-in-Charge. Make: Polycab/ Asian/ Gloster, a) 25 Sqmm 4 Core
b) 35 Sqmm 4 Core
c) 16 Sqmm 4 Core
d) 16 Sqmm 2 Core
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cables of size 63 mm outer dia with all fittings laid in trenches/road/nallahor fixed along wall poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavtiion and earth work shall be measured and paid separately) Make Rex/Poly/Geminie
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cables of size 90 mm outer dia with all fittings laid in trenches/road/nallahor fixed along wall poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavtiion and earth work shall be measured and paid separately) Make Rex/Poly/Geminie
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc , complete all as specified and directed by Engr-in-Charge.
M&L Point wiring complete with stranded copper conductor 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC conduit heavy duty grade ISI marked minimum 20 mm dia but shall be increased as per actual site requirement in accordance with Clause 19.125 of SSR Part-I, ISI Marked, including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable as earth continuity wire with metal flush box 1.2 mm thick of suitable size with 2.8mm thick bakelite sheet complete all as specified and as directed by Engr-in-Charge as given below:- Make of wire: Finolex/RR Cables/Havells a) One light/fan point controlled by one, one way switch
b) One bell point controlled by push button on the same board with other switch.
c) One 5 pin socket outlet 5/6 amps on the same board.
d) One 5 pin socket oulet 5/6 amps on independent board..
Material and Labour for Point wiring complete with 2.5 sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessedin wall / On surface of roof ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame for modular switches, sockets,switch sockets for One 6 pin socket outlet 2in 1 in one 16/6 Amps on Independent Board with required modules complete all as specified and as directed by Engineer-in-Charge. Note: Cost of cutting / chasing on wall and making good after repair shall be measured and paid seperately. Make of cable: Havells/ Finolex/ RR Kable/ KEI
M&L for sub main wiring with two run of 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
M&L for sub main wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
Supply and draw 1.5 Sqmm PVC insulated, unsheathed multistranded (FRLSH) copper conductor cable conforming to IS 602 through existing concealed conduit all as specified and directed. Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
S&F in replacement MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engr-in-Charge. Make Hager/ L&T/ Legrand.
Supply and fix in replacement MCCB 4 pole 100 Amps of Breaking capacity 25KA. complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate. Make- Legrand /ABB /L&T,
Supply and fix in replacement MCCB 4 pole 63mps of Breaking capacity 16KA., complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate. Make- Legrand /ABB /L&T,
Supply and fix in replacement MCCB 4 pole 160 Amps of Breaking capacity 25KA. complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate. Make- Legrand /ABB /L&T,
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately.
Supply only spare parts for Geyser a) Heating element 1.5 KW with rubber gasket . Make-bajaj Model Cladia
b) Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
c) Hot/Cold water connection pipe 450 mm length.
d) 3 core 1.5 sqmm PVC insulated cable 1.5 m long with 3 pin 15 Amp plug top
e) Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia
Supply and fix hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler , complete all as specified and directed by Engr-in-Charge. Make : Copeland/Tecumseh. Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate.
Taking out burnt unserviceable condenser fan motor, rewinding electric motor, single phase 230 Volts of water cooler 40 ltrs/Hrs with super enameled copper wire of same gauge, complete all as specified and directed by Engr-in-Charge.
Supply and fix relay for water cooler of capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make Renetor/ Shriram /Dunfoss.
Supply and fix Thermostat for water cooler capacity 40/80 ltr/hrs, complete all as specified and directed by Engr-in-Charge. Make:Renetor/shriram/Godraj/Danfoss
Supply and fix PVC Float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers, complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC polythene ball suitable to fix to 15mm PVC float valve, complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections of upto 25 mm bore , including cleaning or removal to store, complete all as specified and directed by Engr-in-Charge.
Supply and fix 25mm dia, 3- layer PP-R Polypropylene random copolymer)pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for water supply all PP-R plain & brass threaded polypropylene random including fittings laid in Wall/ceiling/floors.
Supply and fix in repair PP-R Ball valves (brass insert) as per requirement of the site for 25 mm dia bore pipe
M&L in repair 100 mm bore sluice valve, PN 1.6, (ISI Marked) with flange ends any pattern including taking down old existing sluice valve with new Nut, bolts, washers, rubber packing etc , complete all as specified and directed by Engr-in-Charge of the following sizes. Make: Zoloto/ Kirloskar/Leader
M&L in repair 150 mm bore sluice valve, PN 1.6, (ISI Marked) with flange ends any pattern including taking down old existing sluice valve with new Nut, bolts, washers, rubber packing etc , complete all as specified and directed by Engr-in-Charge of the following sizes. Make: Zoloto/ Kirloskar/Leader
Dismantling monoblock pump set centrifugal type of cap 25 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing Unserviceable shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Dismantling Pump set open well type of cap 5 HP, AC, 3 phase, 415 volts from site after disconnecting of electric connection, suction and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with PVC insulated winding wire as per existing gauge and varnishing complete, dismantling pump set for overhauling, replacing Unserviceable shaft sleeve, gland packing, bush, water seal, applying grease etc and reassembling the complete pump after repairs and replacement of parts as required, refixing the same at site incl. electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. Note : Cost of dismantling and refixing deemed to be included in quoted rate.
Supply and fix in replacement cast iron Foot valve cap 80 mm complete all as specified.
Supply and fix in replacement of Contactor 3 pole of cap 40 Amps complete all as specified and directed.
Supply and fix in replacement NRV of bore dia 100 mm complete as specified and directed
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ , complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of ceiling fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge..
Dismantling of Exhaust fan 250mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge.
S&F in repair 10 Watt LED batten luminaire suitable for wall mounting of capacity 2 feet long with voltage range 100-240 volts and inbuilt protection,complete all as specified and directed by Engr-in-Charge. Make: Wipro(LL20-111-XXX-65-NE) or Equivalent in Philips/Crompton Greaves
S&F in repair 20W LED luminaire, nominal lumen output 2000 lm, extruded aluminum housing, IP20,voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed by Engr-in-Charge. Make: Philips/WIPRO(LL20-281-XXX-65AL1)or Equivalent in Philips/Crompton Greaves
S&F in Replacement surface mounted 20W LED luminaire, nominal lumen output 950 lm, IP 20, pressure die cast aluminium ,operating voltage range 140-270 volts,system efficacy > 60lm/W THD<10%, PF>0.9, complete all as specifie0d and directed by Engr-in-Charge. Make: Wipro Cat no LD80-171-XXX-60-SM or Equivalent in Philips/Crompton Greaves
S&F in Replacement 18W LED Luminaires recessed mounted down lighter 5700K system efficiency not less than 100lm/watt,thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires complete all as specified and as directed by Engineer-in-Charge. Make: Wipro Cat no: LD06X-221-XX-57-XX or Equivalent in Philips/Crompton Greaves
S&F in Replacement of Unserviceable light any type LED flood light LM6 high pressure die cast aluminium housing, IP 66, Nominal Lumen output 14000 lm, Colour temprature 5700K, THD<10%, PF>0.95, Operating Voltage 140-270V AC, 50HZ , complete all as specified and directed by Engr-in-Charge. Make: Wipro Cat no: LD20-192-060-57-G2 or Equivalent in Philips/Crompton Greaves
S&F in Replacement of Unserviceable LED street light of capacity 60 Watt, LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro (Skyline LR13-671-XXX-57-XX) /or Equivalent in Philips/Crompton Greaves
S&F in Replacement of Unserviceable LED Street Light of capacity 30 watt , LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Philips Cat Part No BRP 409 or equivalent in Wipro (Skyline LR02) or Equivalent in Crompton Greaves
S&F in Replacement of Unserviceable LED Spot Light of capacity 7.5 watt , 3000 colour lumens with multiple beam tilting angles, no UV radiation and dimmable ballast complete all as specified and directed by Engr-in-Charge. Make: Wipro (LD98)/or Equivalent in Philips/Crompton Greaves
S&F in Replacement of Unserviceable LED under water changing Light of capacity 6 watt , hard chrome plated stainless steel with silicon sealed glass suitable for fountain including DMX driver and DMX controller complete all as specified and directed by Engr-in-Charge. Make: Wipro cat no LU03-950-030-CC-XX or Equivalent in Philips/Crompton Greaves
Supply and fix in replacement following items for maintenance of Internal Electrification , complete all as specified and directed by Engr-in-Charge. a) Lamp holder for Batten fitting.
b) Piano switch, flush type 5 Amps, 1 way.
c) Piano switch, flush type 5 Amps, 2 way.
d) Bell push, flush type 5 Amp.
e) Electric bell Ding Dong type , 230 Volts Single pole.
f) Socket Outlet 2 in 1, 3 pin, 6A
g) Switch socket combination, 6 Amps flush type.
h) Switch socket combination, 16 Amps flush type.
j) 2.5 mfd Capacitor
k) Stepped type electronic fan regulator
Supply and fix in replacment MCB of following rating complete all as specified and directed by Engr-in-Charge. Make legrand/Siemens/L&T, a) 20 Amp SP ,240 volt 'C' Series, 10KA
b) 32 Amp SPN ,240 volt 'C' Series, 10KA
c) 32 Amp TPN,440 volt 'C' Series, 10KA
d) 63 Amp TPN,440 volt 'C' Series, 10KA
Servicing of twice during the contract period of RO Water Purifier 15 Ltr/Hr servicing in every 03 months and comprising of replacement of following:- (a) Filter (Sediment/Carbon Filter) (b) Replacement of minor parts such as SP stem, union male elbow, branch etc NOTE :- (ii) Major parts will be measured and paid separately Make : Kent ACE+ 7litre RO+UF
Supply only for replacement of following spares for RO water Purifier:- a) SMPS
b) Solenoid Valve
c) RO Membrane
d) UF Membrane
e) Pump
SURESH ELECTRICALS
KRISHNA ENGINEERING
SHREE CHAMUNDA ENTERPRISE
Hirachand Sunderji and co
Chamunda Kruparefrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .