| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84,209Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹96,180+₹3,761 (4.07%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | M K Suresh L1 | Rajesh K V L2 |
|---|---|---|---|---|---|
| 1.00Maintenance of Generator building | |||||
| 1.00 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | 228 | kg | 213.21 ₹48,611.88 Lowest | 222 ₹50,616 |
| 1.00 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | 11.01 | sqm | 277.61 ₹3,056.49 Lowest | 289 ₹3,181.89 |
| 1.00 | 10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover | 9 | sqm | 4,140.93 ₹37,268.37 Lowest | 4,307 ₹38,763 |
| 1.00 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | 10 | sqm | 348.25 ₹3,482.5 Lowest | 362 ₹3,620 |
Tender Value
₹84,209
EMD Value
₹2,105
Closing Date
28 Jul 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Additional Irrigation Sub Division Aluva
GENERAL-Maintenance of Irrigation Structures-Maintenance of Generator Room of Kanakkankadavu RCB-General Civil Work- General Civil Work
2026_Irrig_861400_1
IRR/IA/TR/7401/2025_5_2_1/1
Open Tender
Civil Works - Others
Item Rate
kanakkankadavu
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
Yes
₹2,105
Yes
13 Nov 2026
18 Jul 2026
29 Jul 2026
18 Jul 2026
28 Jul 2026
18 Jul 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Maintenance of Generator building | |||||
| 1.001 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | - | kg | - | - |
| 1.002 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | 1 | sqm | - | - |
| 1.003 | 10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover | - | sqm | - | - |
| 1.004 | 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) | - | sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1456785.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
viewsbd.pdf
Tender Documents • 1.64 MB
BOQ_1456785.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .