Executive Engineer DGVCL,SURAT RURAL DIVISION
Tender for works of maintenance of transformers center on ARC basis & Chemical earthing for Puna sub division or any other sub division under Surat Rural Division.
350750
DGVCL/ SRD/E-TENDER/2026-27/ No:46
Open
Electrical Works
Works
Surat
3 documents required · 3 mandatory
₹1,180
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹20,000
30 Sept 2026
30 Sept 2026
30 Sept 2026
21 Oct 2026
30 Sept 2026
Name of work: Tender for works of maintenance of transformers center on ARC basis & Chemical earthing for Puna sub
division or any sub division under Surat Rural Division.
Sr. No. Description Unit Material Charge Total
1 Labour charge for providing of HT/LT bushing goti if required No. 100
1.1 Replacement of LT bushing goti/ Rubber washer No. 40
1.2 Replacement of HT bushing goti/ Rubber washer No. 40
Providing of half stud (Including 2nos Nut & 2nos Washer) on LT side up to 100 KVA
3 Providing of AL. Patta on LT side up to 200 KVA TR if required No. 140 5
4 Providing of AL. Patta on LT side up to 500 KVA TR if required No. 165 10
5 Check and tight earth connection, if required provide lugs & nut-bolt to the neutral LS 0 50
terminal of TRF and to the body terminal of TRF and dist box earth
Replacement of damage LT cable with new one of right capacity (cable provide by
Providing of new termination in form of R,Y,B and N core including PVC tape
7.1 Termination of 25/50/70 Sq.mm cable No. 8 20
7.2 Termination of 300 Sq.mm cable No. 45 20
7.3 Termination of 95/120/150 Sq.mm cable No. 16 20
7.4 Termination of 185 Sq.mm cable No. 23 20
7.5 Termination of 240 Sq.mm cable No. 32 20
Measurement of voltage and ampere during maximum load period minimum
nos. of T/C per day
Check oil leakage from drain off valve/gasket/tank leak etc. and if leakage found at
attend by providing adhasive material, m-seal and give detail of leakage and
topping of oil to maintain proper oil level (oil provide by DGVCL)
10 Checking and replacement of LT Dist box if required 100
Fixing of new dist. Box with complete wiring including clamps, nut bolts etc.
(Suitable for kit kat fuse/HRC fuse)LT distribution box must be of SMC material
10.1 (GTP/SPECS. to be submitted of OEM)and to be supplied from register vender of No. 3150 628
GUVNL and their subsidary company.all the testing norms will be applicable to this
Replacement of detoriarated/providing LT dist. Box with new up to 100 KVA as per coprporate
capacity & crediting it to store.(Suitable for kit kat fuse/HRC fuse)LT distribution sor number
box must be of SMC material (GTP/SPECS. to be submitted of OEM)and to be DGCS/1410/01/2025
supplied from register vender of GUVNL and their subsidary company.all the testing DTD 27-01-2025
norms will be applicable to this material
as per coprporate
Replacement of detoriarated/providing LT dist. Box with new above 100 KVA
10.3 capacity & crediting it to store.(Suitable for kit kat fuse/HRC fuse)LT distribution No. 3150 2084
box must be of SMC material (GTP/SPECS. to be submitted of OEM)and to be
supplied from register vender of GUVNL and their subsidary company.all the testing
norms will be applicable to this material
Checking and replacement of HRC fuse base if required (kit- kat fuse base provide
by contractor on std. make)
11.1 up to 100 amp kit-kat fuse No. 20
11.2 200 amp kit-kat fuse No. 20
Checking and replacement of HRC fuse base if required (HRC fuse base provide by
contractor on std. make)
12.1 630 amp HRC fuse base No. 682 50
12.2 400 amp HRC fuse base No. 525 50
12.3 250 amp HRC fuse base No. 370 50
Checking and replacement of HRC fuse bridge if required (HRC fuse provide by
contractor on std. make)
13.1 630 amp HRC fuse No. 690
13.2 400 amp HRC fuse No. 490
13.3 250 amp HRC fuse No. 352
Providing of proper size of fuse element on HT side (on D.O. fuse with cleaning of
Providing and replacement of sundry items like nut,bolt,washer etc. of appropriate
16 General condition
Clean off all dirt etc from the body of the transformer and tighten all nut-bolt etc.
16.2 Clamping of LT cable as per instruction of incharge supervisor
Cleaning of surronding area nearby transformer center, treeming of tree branches,
removing of crimpers etc.
Submission of the all activity done at location wise in prescribed proforma format
with signature of incharge of supervisor and contractor
Providing of breather if not available with transformer (breather to be provided by
Providing of insulated jumper at HT side from D.O. fuse out side to TC. All three nos.
(Jumper wire will be provided by DGVCL)
Supply & providing of neutral earthing using G.I. strip (Size 25 mm x 3mm flat) to
neutral terminal of X'mer and disl. Box neutral terminal with 3 Mtr PVC rigid pipe.
17 20 Kg solt + 20 Kg coal. G.I. strip should be brought proper shape up to the No. 255 595
equipment (Earth resistance to be measured and earth resistance to be maintained
as per std norms of DGVCL)
Model:ETP/HDR/17/2
18 Terminal Size: 25mmX 6mm Length: 2 Mtr Nos 1480
With clamp & 2 no’sof M10 size SS nut & terminal to T/C neutral separately
using Bolts with connection of earthling 25X 3mm Hot Dip GI strip(per
Transformer/ Earthling 04 Mtr GI patti)Installation of Earthling PIT ,work
includes supply and
labour for connectionall respect.
Ground Conductivity
Improve Material,
19 Hydrolyte Net Nos 200
20.1 LT Side Brass half stud with 2 no brass nut & washer of size 12 mm No. 158 18
20.2 LT Side Brass half stud with 2 no brass nut & washer of size 20 mm No. 300 18
20.3 LT Side Brass Nuts and washer
20.4 12 mm Brass LT side nuts No. 16 12
20.5 20 mm Brass LT side nuts No. 41 12
20.6 30 mm Brass LT side nuts No. 68 12
20.7 12 mm Brass LT side washer No. 10 12
20.8 20 mm Brass LT side washer No. 18 12
20.9 30 mm Brass LT side washer No. 20 12
Breather plastic transparent body cast metal cap and bottom, 1/2'' thread pipe,250
grams.( Dry gel weight 250 gm)
Breather plastic transparent body cast metal cap and bottom, 1/2'' thread pipe,500
grams.( Dry gel weight 500 gm)
In word: Twenty three lacs only (GST EXTRA)
*Rates are exclusive of all Taxes.
*TDS GST Will be Applicable as per Govt.rules & regulation.
1 Whatever Steel Material removed after replacement should be credited to Store.
2 Contractor has to carry out work under Surat-Rural Division.
The contractor has to collect all the required materials from DGVCL store as well as credited the
3 dismantle material to the DGVCL store at their cost.
4 The rates are required with all taxes but exclusive of GST.
5 Party has to work at his own risk.
6 Contractor should have to provide safety tools while working at site.
7 All material utilized for above work must be IS standard only.
Exe.. Engr. (O&M)
DGVCL,Surat Rural Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
(1) SCHEDULE A.pdf
(2) Bid Document.pdf
(3) SRD Standard Operating procedure for tc maintenence.pdf
(4) DRAWING SMC FUSE BOX.pdf
SCH-B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .