Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical As per attached OFCH/CWC-I Decision |
| 2 | Accepted-Technical | Accepted-Technical As per attached OFCH/CWC-I Decision |
| 3 | Accepted-Technical | Accepted-Technical As per attached OFCH/CWC-I Decision |
| 4 | Accepted-Technical 89 3 2 RANI MARKET VIVEKANANDA ROAD RISHRA HOOGHLY WEST BENGAL 712248 | HOOGHLY | WEST BENGAL | 712248 | Accepted-Technical As per attached OFCH/CWC-I Decision |
Tender Value
₹44.1 L
EMD Value
₹88,300
Closing Date
4 Jun 2026, 2:00 pmClosed
CHIEF GENERAL MANAGER, ORDNANCE FACTORY CHANDA
ORDNANCE FACTORY CHANDA
REPAIRS/REPLACEMENT OF LIGHT SYSTEM INCLUDING LIGHT FITTING AND LIGHTING PROTECTION SYSTEM IN BLDG. NO. 254, 244, 460, 429 AND 529 U-VIII INSIDE FILLING AREA AT O. F. CHANDA.
2026_MIL_277404_1
OFCH/EO/11 OF 2026-2027
Open Tender
Electrical Works
Works
180 days
ORDNANCE FACTORY CHANDA
As per Attached Tender Documents
10 documents required · 10 mandatory
₹0
₹88,300
Yes
3 Jul 2026
14 May 2026
5 Jun 2026
14 May 2026
4 Jun 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Cat (A) -Items to be supply and fixing | |||||
| 1.01 | Dismantling/taking down carefully existing conduit pipe and other accessories. All as specified and direction by E-I-C. | 226 | PER POINT | - | - |
| 1.02 | Supply and fixing wiring for circuits in 19mm steel conduit along with wiring accessories with 2X2.5 Sq.mm+1X1.5 Sq.mm as a earth wire (in each meter length) heavy duty 1100V grade, 50Hz AC PVC insulated, PVC sheathed multistranded copper conductor as per IS: 694-1990 make-Havells/Polycab/Indicab or Equivalent for carrying out wiring of circuit of any length form DB/Switch upto load point. All as specified and direction by E-I-C. | 3,501 | RM | - | - |
| 1.03 | Supplying & Drawing of 2X2.5 Sq.mm + 1X1.5 Sq.mm as a earth wire (in each meter length) heavy duty 1100V grade, 50 Hz AC PVC insulated, PVC sheathed, multistranded copper conductor as per IS: 694-1990 make-Havells Polycab/Indicab or Equivalent for carrying out wiring of a circuit of any length from DB/switch upto load point. All as specified and direction by E-I-C. | 2,445 | RM | - | - |
| 1.04 | Supply & drawing of 2X6 Sq.mm + 1X4 Sq.mm as a earth wire (in each meter length) heavy duty 1100v grade, 50 Hz AC PVC insulated, PVC sheathed, multistranded copper conductor as per IS:694-1990 make-Havells/Polycab/Indicab or Equivalent for carrying out wiring of a circuit of any length from DB/switch upto main switch. All as specified and direction by E-I-C. | 90 | RM | - | - |
| 1.05 | Supply and fixing of Flame proof 4 WAY Junction box. Material aluminium dia costing LM6, 16A, 250V, four side wire entry through steel conduit having threaded 19 mm BSW with metallic blanking plug -04 Nos. all as per the direction of E-I-C. | 350 | EACH | - | - |
| 1.06 | Supply and fixing of Earth continuity conductor/earthing of 2 mm G. I. steel wire drawn along with conduit properly fix to the conduit with copper clips. All as specified and direction by E-I-C. | 3,600 | RM | - | - |
| 1.07 | Supply, Fixing & Connection of sheet metal enclosure for DB, Double door, TPN 415 V, 04 Way, per phase complete fixed with (Make-L&T, ABB OR Equivalent)
a) 4 pole MCB TPN, 63 A MCB, 10KA – 01 no. Make-L&T, ABB OR Equivalent (incomer)
b) SP, 10A MCB, 10KA-12 no. Make – L&T, ABB or Equivalent. All as specified and direction by E-I-C. | 12 | EACH | - | - |
| 1.08 | Excavating for earth pit, n. exc. 1.5m wide and n. exc. 1.5m in depth n soft/loose soil and getting out etc. All as per specified & Direction by E-I-C. | 18 | CUM | - | - |
| 1.09 | Supply and fixing of Earthing complete with G. I. earth plate electrode 600x600x6mm thick buried directly in the ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below ground level, connected to galvanised earth strip 25x4mm as earthing lead upto test point, all as specified and shown in electrical plate no. 3 of SSR part II and testing on completion etc. all as per the direction of E-I-C. | 12 | EACH SET | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.65 MB
AnnexureD.pdf
Tender Documents • 0.26 MB
AnnexureC.pdf
Tender Documents • 0.26 MB
AnnexureB.pdf
Tender Documents • 0.14 MB
AnnexureA.pdf
Tender Documents • 0.17 MB
BOQ_323975.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .