Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹45.7 L+₹3.3 L (7.75%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | L3₹46.4 L+₹4.0 L (9.31%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | L4₹48.2 L+₹5.7 L (13.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 5 | L5₹48.6 L+₹6.2 L (14.6%)Rejected-Finance 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L5 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Oct 2022, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
SPECIAL REPAIRS TO STREET LIGHTS AND OTHER SANCTIONED WORKS AT INS DRONACHARYA
2022_MES_553729_1
8858/E8/GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹96,000
Yes
14 Nov 2022
22 Sept 2022
26 Oct 2022
22 Sept 2022
24 Oct 2022
10 Oct 2022
Amount
Excavation in trenches for under ground cable n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft and loose soil including forming bottom surfaces to required level complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified & directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
Supply and laying common burnt old size sub class B bricks locally availble as in cable protection, laid length of brick perpendicular to length of cable complete all as specified and directed.
M&L for riddle sand for cushioning to under ground cable in layers ( 8 cm before laying the cable and 15 cm after laying the cable) in trenches for cable protection complete all as specified & directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in copings of poles etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified & directed.
Supply, laying & fixing along the poles/walls or passing through pipes or laid in trenches under floor or through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable, 1100 volt grade heavy duty with aluminium conductor overall served with an outer sheath of PVC complete of size 10 Sqmm 2 Core all as specified & directed by Engineer-in-charge. (Note:- Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately).
-Ditto- all as per item No 7 above but of size 16 Sqmm 4 core
Supply & fixing 50mm bore, GI tubing light grade (ISI marked) with fittings laid in trenches or on pole, fixed to wall or ceiling or floor for protection of cables with MS clamps complete all as specified & directed by Engr-in-Charge
Material and labour for road cutting in bituminous road not exceeding 30cms deep for laying / passing under ground cables complete all as specified and directed (Unit rate shall be inclusive of Earth work if required).
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate, 100mm thick in cutted/dismantled portion of road and making good after laying/passing the cables complete all as specified & directed.
Supply and fixing thermoplastic cable junction box IP 66 of size (130x180x77mm) halogen free and weather proof for out door installation( with metric knockouts for cable entry ) Make : HENSEL Cat Part No KF1010B or eqv make in Appendix 'C' including taking down old PVC junction boxes complete all as specified and directed.
Supply and fixing Dynamic light column of 50 Watt,3000K 3mtr long with die-cast amuminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP65 protection with a remote control to enable RGB tunable output complete all as specified and as directed. Make - Bajaj Cat Pt No BLSLC 50 W LED RGB 3M or eqv make in Appendix 'C'
Supply and fix tri Colour light column of 50Watt with die-cast amuminium pipe housing with cylindrical opal polycarbonate diffuser designed for rugged outdoor usage & IP65 protection with Tricolour and tratic white output switch complete all as specified and as directed.Make - Bajaj Cat Pt No BLSLC 50W LED TRI 3M or eqv make in Appendix 'C'
Supply and fix LED flood light luminaire of 80 watt,5700K with pressure die-cast housing and toughened glass and individual LEDs with secondary lens optics with IP66 ingress protection. 4 kv in-built and 10kv external surge protection. efficiency 120Im/W incl nesessary fixing arrangements for the fittings on wall/ceiling etc incl taking down old flood lights complete all as specified and as directed. Make - Bajaj Cat Pt No PRAZE 96L WH NB-A5 TG SD complete all as specified and as directed.
Supply and fix LED Coloured flood light luminaire of 180 watt, with pressure die-cast housing and toughened glass and individual LEDs with secondary lens optics with IP66 ingress protection incl nesessary fixing arrangements for the fittings on PCC foundation/MS channel etc with suitable nut bots incl taking down old flood light fittings complete all as specified and as directed. Make:Shakti/Bajaj/Havells/Wipro
M&L for taking down old post top lantern poles of any length, including dismantling of PCC foundation etc and removing the demolished poles/debris etc from site complete all as specified and as directed.
S &F Feeder pillar box housing in sheet metal enclosure of MS sheet 3.0 mm thick and angle iron 40x40x6mm frame incl copper bus bar of 63 Amps mounted on porcelin insulators including arrangement for cable gland for incoming and outgoing cables, locking arrangement, suitable foundation/platform for mounting the FPB with space for and including the following switch gears:- (a) MCB TPN 40 Amp 415 volts - 01 No (b) MCB SP 6-32 Amp 230 volts - 03 No (c) Led Indicator lamp - 03 Nos
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of G I or steel all as shown in electrical plate No. 5 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and MS cover slab, connecting lead wire from test point to FPB complete all as specified & as directed
Taking out UNSV UG cables of any sizes from trenches/walls including all mounting accessories incl making good to disturbed areas complete all as specified
Dismantling unserviceable PCC/RCC/steel poles Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed.
Supply, laying and testing weather proof flat twin core cable with aluminium conductor of size 2.5 Sq.mm 2 core including taking down complete all as specified
Supply of 8 mtr height hot dip galvanised octagonal poles with 130 mm bottom A/F & 70 mm top dia made up of 3mm thick.HR sheet alongwith base plate of size 200X200X12mm thick With 04 Nos of M20 X 600 mm long J type EN 8 grade foundation bolts with Double arm bracket suitable for 75mm OD (Length of arm as per site requirement ) and suitable opening on pole for making connection with provn of MCB TPN 20 amps complete all as specified and as directed.
Supply of 8 mtr height hot dip galvanised octagonal poles with 130 mm bottom A/F & 70 mm top dia made up of 3mm thick.HR sheet alongwith base plate of size 200X200X12mm thick With 04 Nos of M20 X 600 mm long J type EN 8 grade foundation bolts with single arm bracket suitable for 75 mm OD or made as per direction of Engr-In -Charge complete all as specified and directed .
Supply and fixing SMC junction box size of 240x130x95 mm fixed on pole including provn of MCB TPN 20 Amps fixed on rail inside box with proper hinges locking arrangements with provn of clamping accessories complete including taking down old unsv item all as specified
Supply and fixing of Prestressed concrete pole, 9 mtrs long ,102 mm x 152 mm at top and 102 mm x 289 mm at bottom class 10 including bracket complete all as specified
M&L plain cement concrete 1:4:8 (40mm graded stone aggregate) in foundation, filling and mass concrete,for foundation of poles etc. including use and waste of formwork as required/ordered, complete all as specified and as directed.
M&L plain cement concrete 1:3:6 (40mm graded stone aggregate) in foundation, filling and mass concrete,for foundation of poles etc. including use and waste of formwork as required/ordered, complete all as specified and as directed.
S & F LED in repair of street light fittings 45 Watt energy saving LED street light made up of pressure die cast housing with toughned glass and individual high power LED as secondary optics, IP66 protection and impact resistance of IK07 including necessary electrical connection from junction box to light fittings including dismantling/taking out old unserviceable street light fittings of any description and removing of dismantled material from work site complete all as directed. Make-C&S/Havells/Bajaj
S & F in repair of Decorative LED light of 60 W pressure cast aluminium PU Painted housing with casted aluminium heat sink optical grade PC diffuser constant current electric driver provided with high voltage open and short circuit protection internal surge protection of 10 KV provided for additional safety .Luminaire should have CCT of 5700 CRI>70 IP 65 Protection ,IK08, PF>.95, thd<10% operating voltage range of 120 - 280 v AC complete all as specified Make -Bajaj Cate Part No -BGCPNP 60 W LED WW SM -Archner Plus or Eqpt in Havells /CG
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to GI strip of 32x6 mm by means of nut, bolts, check nuts and washers of galvanized iron or steel as shown in electrical plate No. 3, including necessary earth work and excavation , charcoal dust, common salt, PCC chamber, RCC cover 40mm thick 1:2:4 using 20mm graded stone aggregate reinforced with 6mm dia round bars 75mm C/C both ways, test point and watering pipe complete, including connecting to earthing test point or to DB / Panel complete as directed by Engr in charge and testing resistance etc complete, including taking down old earthing complete all as specified and as directed. Note: (i)The rate quoted shall be deemed to be included for main earth lead from earth electrode to test point up to 7.5 m only. (ii) On testing after completion if the desired earth resistance not optained as per IE rules the earthing will be redone by the contractor as directed by Engnr in charge with out any extra cost to Govt.
S & F in repair of 20 mm size non metallic PVC conduit including all fittings and fixing accessories complete all as specified and as directed.
M B JAYAVEL
WELTRONENGINEERINGSERVICES
SRIRAM ELECTRICALS
NLK Construction
G.JANAKIRAMAN CO
MS BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .