Executive Engineer, Electric (R&B) Division, Rajkot
Providing and Erecting LED Street Light in Dungarpur Village Near Dungarpur - Kanesara - Kothi-Nani Lakhavad Road , Taluka:Rajkot , Dist: Rajkot .
364288
11 of 2026-27
Open
Electrical Works
Works
Rajkot
8 documents required · 8 mandatory
₹900
Executive Engineer, Electric (R&B) Division, Rajkot.
₹13,200
6 Nov 2026
6 Nov 2026
6 Nov 2026
20 Nov 2026
6 Nov 2026
90 days
Name of work: Providing and Erecting LED Street Light in Dungarpur Village Near Dungarpur - Kanesara - Kothi-Nani
Lakhavad Road , Taluka:Rajkot , Dist: Rajkot .
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Supplying and erecting Flexible PVC insulated multi strand
multi core 1.1 kv grade ISI marked copper wires of following
size to be erected as directed.(e) 1.50 Sq.mm 3 core round
providing and erecting Miniature circuit breaker single pole
0.5A to 2A system and having breaking capacity 10 KA to be
erected in existing box. confirming to IS 8828/1996 with ISI
Providing & erecting 415V MCB Four Pole Switch for
Lighting Load (B curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity
(b)40 Amp. Cat.III
Sheets steel powder coated enclosure suitable for incorporating
One/Two nos. MCB.
Providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
phase and neutral 415V,50Hz. having characteristic of quick
action & tripping with all advance feature & do not incorporate
any electronic component for following Max. rating erected as
directed.(ii) 40Amps. FP Cat. III
Providing and erecting HOT deep Galvanised iron strip wire
Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
7 including value of earth resistance of installation duly stamped 0.00
and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
1 Ea Length of pipe - 1 Mtr 4591.46
Back filling compound - 1 Nos Bag of 15 Kg.
Providing and erecting Pipe type earthing having 150 cms.long
and 2.5 cms. dia. galvanised iron pipe with coupling and buch
buried in specially prepared earth pit complete with necessary
SWG earth wire.
For using salt and charcoal / coke as required for pipe type
Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for 1.1 kV.
10 60 Mtr to be laid on wall with necessary clamps or in existing trench / 184.83
pipe of following size of cables (A) 4 core 16 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured
cable multistrand / Solid Aluminium conductor for 1.1 KV. to
be laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (B) 4 core 6 Sq. mm
Making trench in Hard Murrum / Tar Road of suitable width of
90 cm or required depth for laying any size of cable or locating
the fault all over the run and back filling the same and making
the surface as normal ground.
(B) If additional machinery like hammer driller or JCB use
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
cables.(B) 2 to 4 core 6 Sq. mm
2 Ea (D) 2 to 4 core 16 Sq. mm 47.47
Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
14 200 Ea pressure tool & connected to switchgear terminals with 6.06
brass/cadmium plated nut bolts in an approved manner. (A)
Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground /
road surface for enclosing cable (A)50 mm outer dia
Supplying and erecting approved make Octagonal pole made
from HR sheet steel. The pole should be made as per IS. and
shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with
integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for
16 50 Ea MCB Mounting, stud type terminal and arrangement for cable 9011.22
termination to be erected With Suitable foundation (Included)
as per details given by manufacturer considering site
requirement.(D) 6 Mtr. Long 70 mm Top X 135 mm bottom
dia, 3 mm thickness with 200mmX200mmX12mm base plate,
4-M20 Bolts and 600mm long with necessary G.I. J Bolts
.Approx Pole weight 59 kg
Providing and erecting street light pole bracket comprising
main B Class GI pipe of 4.2 cm/require outside dia. complete
with suitable B Class G.I sleeve tubing of approx.
45cms.length and suitable for 76.5 mm / 80mm. / require size
pole top having sufficient fasteners for fixing the brackets and
17 50 Ea having spread of 1 mtr. length with suitable rise as per site 614.08
condition & suitable welded stiffener reducer and nipple with
check nut complete painted with one coat of Red oxide / PU
base primer and two coats of Aluminium / PU paint. paint with
following nos of arms.[A] Single Arm bracket 1 Mtr
Supplying & erecting approved make Digital time switch
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts
Minimum switching setup time 1 minimum & LCD display.
Also comprised permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary connection
erected as directed.
Supplying & erecting power contactor ,AC3 duty for time
19 1 Ea switch complete erected as per direction Cat III (D) 4 pole 2782.55
Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
20 embossed 160 to 270 V,Power Factor more than 0.95, THD < 0.00
10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and
50 Ea ,Light must have 440VAC line supply with over-voltage 5080.30
protection. (iii) 60 - 89 watts Cat-lll
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
Supplying & erecting IP 55 grade following size section pillar
fabricated from joint less M.S. Sheet with angle iron legs made
from jointless M.S. Angle with cable clamps to be buried in
ground to have appropriate erection to work uniform until
erected with cement concrete foundation and 45 cm high bricks
work finishing with plaster etc. hinged double door internally
supported on both side, with internal and outside looking
arrangement with look and keys in duplicate 35 x 35 x 5 mm
M.S. Angle of Two Nos. one is welded and other with nut and
bolt for erecting Bakelite sheet. Painting the Section Pillar
inside and out side with three tank powder coated paint.
section pillar roof should be without joint with water leakage
proof & tested as per IP 55 test & followed by IS 2147 of
(B) 75 X 60 X 45 cm section pillar fabricated from 16 Gauge
1 Ea MS Sheet with angle iron legs 45 cm long made from 35 X 35 3595.60
X 5 mm thick MS angle.
Supplying KITKAT pattern porcelain cut-out fuse with base of
22 3 Ea following current capacity erected on existing block board.(v) 278.76
Supplying and erecting HYLAM sheet on existing angle iron
frame.for following thickness (C) 6mm
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
Qty. Unit estiamted
providing and erecting Mains with ISI marked, 1.5KV grade
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected
24 24 Mtr in existing pipe of following size (Specifically for control 177.76
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
required. (g) One wire 16.00 sq. mm
Note:- The Credit of dismentalled materials for Rs.00.00 shall be recovered from the First R.A. bill payable to the contrator and
there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount of
my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation
regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other
tender documents of this work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of
Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote
the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-in-
Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the
agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
MAKE FOR ELECTRICAL ITEM (3).pdf
SBD.pdf
SCH-B (3).pdf
SPECIAL CONDITION (2).pdf
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for single Tender.pdf
ONLINE_NOTICE(R-2)(dn).pdf
ANNEXURE-A.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .