Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹45.0 LAccepted-AOC AT JAMUATAND NEAR HIRAK ROAD PO NAWAGARH DIST DHANBAD JHARKHAND | ₹45.0 L | 1 | Accepted-AOC AOC |
| 2 | 2₹49.2 LRejected-AOC BHANDARIDIH KATRAS DHANBAD 828113 | DHANBAD | DHANBAD | JHARKHAND | 828113 | ₹49.2 L | 2 | Rejected-AOC L2 |
| 3 | 3₹50.0 LRejected-AOC | ₹50.0 L | 3 | Rejected-AOC L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically not Qualified |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
25 Nov 2025, 5:00 pmClosed
District Engineer, Zila Parishad, Dhanbad
District Engineer, Zila Parishad, Dhanbad
Construction of BPHU Building in the premises of Baghmara P.C.H, Block Baghmara, District-Dhanbad
2025_ZPDH_106602_1
19/2025-26/DE/ZPDH/DHANBAD/2nd Call
Open Tender
Civil Works
270 days
Baghmara
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
₹1 L
26 Mar 2026
14 Nov 2025
27 Nov 2025
14 Nov 2025
25 Nov 2025
14 Nov 2025
EARTH WORK Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item B) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)all complete as per approved design, building specification and direction of E/I.
Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)all complete as per approved design, building specification and direction of E/I.
Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)all complete as per approved design, building specification and direction of E/I.
Providing and laying in 50 mm dpc position specified grade of reinforced cement concerte, excluding the cost of centering, shutteing, finishing and reinforcement- All work up to pilnth level 1:2:4(1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size)all complete as per approved design, building specification and direction of E/I.
making plinth protection Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1 :3:6 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) all complete as per approved design, building specification and direction of E/I.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)all complete as per approved design, building specification and direction of E/I.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)all complete as per approved design, building specification and direction of E/I.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts,
Centering and shuttering including strutting, propping etc. and removal of form for Roof , slab
Providing Tor steel reinforcement of 8mm,dia rods as per approved design and drawing -do- -do- 8MM
Providing Tor steel reinforcement of 8mm,dia rods as per approved design and drawing -do- -do- 10MM
Providing Tor steel reinforcement of 8mm,dia rods as per approved design and drawing -do- -do- 12MM
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angleof section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge DSR-10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting and fixing 35mm thick solid core type non- decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35mm thick solid core type non- decorative double leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and fixing granite 18 mm thick gang saw cut, mirror pollished, premoulded and prepollshed mechine cut for flooring, kichen, platform, vanlty counters, window sills, faclas and similar locations of required size, approved shade, colour and texture lald over 200 mm thick base cement mortar 1:4 ( 1 cement: 4 coarse sand). Joints treated with white cement, mixed with matching pigment epoxy touch ups, including rubbing curing moulding and polishing to edges to give high glloss finish etc, complete al all levels.
Providing edge moulding to 18 mm thick marble/granite stone counters, vanities etc. Including machine polishing to edge to give high gloss finish etc, Complete as per design approved by Engineer-in- Charge.
make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. 29.1 11.21.1.1 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20m m thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
Providing and Laying 25mm. Thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of time morter (1:1:1) (Line putty : surkhl: coarse sand) laid over and jointed with grey cement slurry mixed with plgment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curring, taxes and royalty all cmplete as per building specification direction of E/i. 600x600mm Size.
Providing and laing 25mm. Thick kotah stone riser of steps. Skirting and pillers of approved size, texture and colour over 13mm thick cement morter(1:3) and jointed with grey cement slurry mixed with plgment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I.
Providing and laying Ceramic glazed floor tile of size 300x300mm (Thikness to be specifyed by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, lvory, Grey, Fume Red Brown, laid on 20mm thik cement morter 1:4(1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching plgment etc, complete.
Providing and laying 1st quality Ceramic glazed wall tiles thicness to be specified by the manufacturer) in wall over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing pollshing and cost of curing. taxes and royalty all complete as per bullding pecification and directionof E/I
Water proofing for Old and New Roof Slab :- Providng and laying water proofing treatment on roof slab by applying tow component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofing coating as per manufacturer specification-With following steps:- (a) Suface preparation:- Providing and cleaning of concrete surface to remove dust, iol, grease including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools, complete. Ponding test to be done after pugging all outlets and to be cheded from soffit to identify seepage, ladkage. On indentification of seepage, cement grouting to be done with non shirnk expanding admixture of Sika India Pvt. Ltd. MYK Schombeg/Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints usch as those between the parapet wall and the roof slab etc. Shall be chamfered with '150mmX'150mm fillet lf mortar (Cement sand- 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or requivalent Before chamfering a prime coat shall be give with the slurry of acrylic polymer Reparing surface irregularities, damaged concretein base slab, dead cracks if any, with and acrylic polymer modified reqpair mortar including a coat of bonding agent of the same with cement slurry including all materials labour, tools, complete. (b) 1st Coat :- Apply 1st coat of two component acrylic modidied, ready to use, flexible cementitious material on surface saturated dry roof and inisde wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm oil Fibre glass cloth to lay when the fist layer is still greeb. 1st ciat sgiykd ve aookued @1.50/kg/sqmt/coat for the purpose of measurement the entire treated surface will be measured." (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified ready to use flexible cementitious materials right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied@ 0.7kg/sqmt/coat. For the purpose lf measurment the entire treated surface will be measured." alter three days of drying the 2nd coat, the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage,
teakage from soffit and if found necessary rectification to e be done as per satisfation of E/I. The Watqrproofing Brand: *Sika Topseal 109hi/Fosroc Brushbond RFX/ Dr Fixit Pidiffine 2KI MYK Aqraiin TG Product Performance- Chemical Base Part A.Acrylic copol,mer, Part 13 Specially graded cementitious powder-Density 1.6 kg/l (mixed density) at +270 Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.)4624) Slant-shear Bond Strength-4 N/mm2 (According to FIP 5.15) Flongation at Break- 35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTMD 2370) (D )Protection of treated with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in altematepanels lf 2mtx2mt keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS2645@ of 100 ml perbag of cement to be added in the screed concrete (paid separately for this items) all corners shal be charfered with 150mmx150mm fillet. The rain water outlets shal be just leveled with the scree concrete to ensure smooth descharge of water- the perpheral gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensisive epoxy putty of Sika India Pvt.Ltd./IVIYK Schomberg/Dr Fixit / Fosroc. For the purpose of measurement the entire treated surface will be meaured."(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand-Sika India Pvt. Ltd./MYK Schomberg/ Dr Fixit/Fosroc
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and filling 6 MM Groove between 50 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge.(with 18% GST) brand:- Sika- Polysulphide Fosroc-l-hloflex 600 Dr Flxit Pidiseal PS(42P), MYK seal PS or Eulvallent
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm of aproved brand and manufacture ofev the plastered wall surface to prepare the surface even and smooth complete
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Finishing walls with acrylic smooth exterior paint of required shade, new work ( Two or more coas app;ied @ 1.67 ltr/10sqm over and incuding priming coat of exterior primer applied @2.20 kg/10sqm
Providing and fixing aluminium work for doors, windows ventilators and partitions with exruded builtt up standard tubular sections/appropritate Z sections and other sections of approved make conforming to IS: 733 and IS:1285 fixing with dash fasteners of required dia and aize including necdessary filling up tthe gaps of fundtions. i.e. at top bottom and sides with required EPDM rubber/neoperrne gasket etc. Aluminium sections shall be smooth. rust free straightt mitred and joined mechanically wherever required including cleat andle. aluminium snap beading for glazing panelling. C.P brass/ stainless steel screw For fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron)
For shutters of doors windows & ventilators including providing and fixing hinges/plvots and miking provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separatrly) powder coated aluminium ( minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): DSR 21.3.2 With float glass panes of 5 mm thicknes
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
SAND, LEAD - 13 KM.
STONE CHIPS, LEAD -18KM.
BRICKS, LEAD- 25 KM.
CEMENT, LEAD- 15 KM
STEEL, LEAD- 15 KM
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2x1.5 sq mm + 1x1.5 sq mm earth wire
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4/5 Module (78mm x140mm x 50mm)
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with1.5 sq.mm FR PVC insulatted. copper conductor single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc.as required.
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) 6 Way (4+18), Double Door Horizontal Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required. 6 / 32 Amp Single Pole
40 Amp TPN
Amp TPN
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required. 63 Amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor PVC insulated cable including termination complete as required in existing cable tray. 16 sq mm ISI Marked, FR LS PVC insulated, single core copper conductor cable.
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required. 10/12 W LED Tube Light
20/22 W LED Tube Light
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :-Usha/Crompton / Havells .
Supply Installation, Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 sq.mm FR PVC insulated copper wire suitable for 230V 50 Hz, Single phase supply etc. complete as required. Make :- Usha/Crompton /Havells .1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. (ii) E.W.C. with 'S' trap (b) 10 lit. low level PVC Cistem
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : 17.11.1 Size 450x300x150 mm
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete Flexible Pipe 32mm Dia
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing flanged cleanout plug with M.S. flanged tail pieces, blind flang, 6mm dia nut & bolts, gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required with 100 mm dia. Pipe
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Supplying fitting and fixing H.C.l. pipes with ear of approved make confirming to l.S.l. 1729 including supplying nails and bobins short pieces, cutting loose collars,lead and yarn for making lead caulked joints, cutting pipes to size including earth work or scaffolding where necessary etc. all complete as per specification and direction of P l(a) 100 mm dla
(b) 75 mm dla
(c) 50 mm dla
Supplying and flxing H.C.l. fiftlngs of approved make confirming to 1.S.S.1729 includlng supplylng nails and bobines lead and yam from making lead caulked joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/lc (i) 100 mm dia (wt. 10.5 Kq. app.)
(i) 100 mm dia (wt. 5.5 Kq. app.)
Supplying all tools and labours and cutting chajja, Cornice, for laving H.C.l. Pipes and maklng good the same as oer Specification and direction of E/|.
Cutting drain width wise above G.L. for laying H.C.l. pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in (1:4) with neat cement punning as per specification and direction
Making holes in walls for laying H.C.l. pipes and restoring the same after pipe laying as per specification and direction of E/1. (a) 125mm dia
Supplying materials and labour for painting the exposed H.C.l' pipes and fittinos with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/1. (a) 50 mm dia
(a) 80 mm dia
(a) 100 mm dia
Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The
fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint. 110 mm (OD) SWR Pipe
Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Exposed on wall Terrace) 25 mm nominal outer dia pipes
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 32 mm dia, nominal bore
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality 25 mm dia, nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete. 32mm nominal bore
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Constructing masonry Chamber 60x45x50 cm,inside with 75 class designation brick work in cement mortar 1:5 (1 cement:5 fine sand) for water meter complete with C.I. Doble flap surface box 400x200x200mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design With F.P.S. bricks
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to100.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Goods & Service Tax (G.S.T.) -
Labour Cess -
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.62 MB
Tendernotice_2.pdf
PDF • 0.39 MB
BOQ_143705.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid