Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA 390 002 | VADODARA | VADODARA | GUJARAT | 390002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.2 L+₹7,313.79 (0.28%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹56,120
Closing Date
4 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Harikesh Meena EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2025_MES_706406_1
8850
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE ARMY BARODA
₹56,120
Yes
21 Jul 2025
2 May 2025
5 Jun 2025
2 May 2025
4 Jun 2025
17 May 2025
3 May 2025 - 10 May 2025
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose Soil
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan & n exc 1.5 m in depth and getting out in soft / loose soil complete all as specified & directed
M&L for antitermite treatment work by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L for antitermite treatment work by treating the top surface of filled earth under floors at the rate of 5 litres of emulsion per square metre of surface
M&L for antitermite treatment work by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall.
M&L for antitermite treatment work by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area.
M&L for providing cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed.
Removing excavated material of soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed.
M&L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 11 herein before but 6mm to 8mm dia.
All as per item No 11 herein before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders
M & L RCC- M-25 (design Mix) using 20mm graded aggregate for Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete all as specified and as directed.
M & L RCC- M-25 (design Mix) using 20mm graded aggregate as in Columns, pillars, piers, posts and struts and mass concrete and all as specified and as directed.
M & L RCC- M-25 (design Mix) using 20mm graded aggregate as in chajjas and mass concrete all as specified and as directed.
M & L RCC- M-25 (design Mix) using 20mm graded aggregate as in roof beam, Beams, cantilevers, bressummers, lintels over 1.5m span and all as specified and as directed.
M & L RCC- M-25 (design Mix) using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and all as specified and as directed.
Use & waste of formwork for rough finished Flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work.
Use & waste of formwork for rough finished Flat surfaces of pillars, posts, struts, piers, columns and stanchions.
Use & waste of formwork to rough finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc .
Use & waste of formwork for rough finished Surfaces of Concrete Measured Flat For Chajja
Use & waste of formwork for Rough Finished flat Surfaces to soffits and suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping)
M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:4
M & L Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:3
M & L Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement)
M & L Rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC as per manufacturers instructiion for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately).
M & L Rendering 5 mm thick on fair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:3 for finished even and smooth (without using extra cement)
Supply only Liquid water proofing compound all as specified and directed.
M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of 2mm average thickness wall care putty (birla/ as per list of makes) and one coat of primer all as specified and as directed.
M& L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash.
M & L Cement concrete type B1, 1:2:4 (20 mm graded stone aggregate) as in coping, bed plate or for hold fast etc.
M & L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by GE.
S & F for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M & L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework (caging) of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed
M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
M & L for 19/20mm thick pre-laminated Interior Grade One Side Laminated Particle board as in pelmet box etc complete all as specified and as directed.
S & F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed
S & F 150 mm size extruded aluminium alloy handles, fabricated type anodised
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S & F floor door stopper of aluminium alloy body and tongue, overall length of cover plate 140mm anodised with hard drawn steel spring, fixed in floors complete all as specified and directed.
M & L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/Angle iron frame/PVC door frame with screw complete all as specified and directed.
S & F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolt, if required hooks (stay), heavy for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps hold fasts, wall ties, hooks for hanging fans, plain angles cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 310-O or Fe 410-O
S & F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete & as per directions of Engineer-in-charge.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6
M & L for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade including 10 mm thick rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4.
M&L Granite (of any type and colour) work (table rubbed and polished) 18 to 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed.
M&L Cement Concrete 75mm thick 1:4:8 type D2 (using 40mm Graded stone Aggregate) as in Sub Base of floor.
M & L for Virified Ceramic tiles 8 to 9 mm thick any type of shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6 all as specified and as directed.
M & L Cement Concrete 25mm thick 1:2:4 type B1 (20mm Graded stone aggregate) as in Sub Base of floor.
M & L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in paving finishing cone surface (plinth protection) even and smooth without using extra cement.
M & L hardcore of guage exc 63mm but not exc.100 mm, deposited, Spread and levelled In layers not exc. 15 Cm thick, watered and rolled/rammed to a true surface
M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.40 Ltrs/Sqm, 3 mm thick APP modified polymeric membrane of weight of 3 kg/sqm with non-woven polyester reinforcement shall be laid over a coat of bitumen S-35 grade (30/40) applied @1.20Kg /Sqm (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps, joints & overlaps shall be sealed and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge (Note: the primer and the membrane to be used shall be of the same manufacturer and to be applied by authorized applicator of OEM).
M&L 10mm thick rendering on roof in CM 1:3 mixed with WPC as per manufacturer's instructions of cement for finished even and smooth without using extra cement over PCC surface for laying APP membrane on roof (WPC will be measured and paid separately).
S & F Sinks made of stainless steel 1mm thick or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified.
S & F 500 Ltrs Rotational moulded polyethylene water storage tanks three layered 'White' (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S & F Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut complate, screwed for iron pipe or brass ferrule and fixed
S & F for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
S & F for 75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent all as specified and as directed.
S & F for 15mm bore chromium plated fancy type bib tap long body, screwed down, high pressure for iron pipe or for brass ferrule
S & F for 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F for 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
S & F tubular curtain rails 25mm dia stainless steel 202 grade drapery type complete all as specified directed
S & F in repairs stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be approved by GE at the time of execution) as directed
M & L Plain cement concrete (1:3:6), type C-2, using 40 mm graded stone aggregates as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides of pipes with concrete after the pipes are laid and tested for 150 mm bore pipes complete, all as specified
M & L 150 mm bore of pipe reinforced concrete pipes, class NP 2 with one collar per length of pipe laid in trenches at any depth including jointing and testing complete, all as specified.
M & L for cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) in manhole, channel rounded or chamfered on edge included neccessary formwork complete all as specified and directed
Extra for forming fair finish to drain or channel 30 cm internal girth in cement concrete using extra cement including forms moulds/mitred stopped ends etc.
M & L for RCC (Design Mix) M-25 (20 mm graded stone aggregate) Walls, retaining walls, ballast walls and the like; any thickness, above top of footings, including attached pilasters and buttresses.
M&L for providing precast cement cocrete type B1 1:2:4 (20 mm graded aggregate) as in cover slabs for manholes etc. and similar articles with plain faces.
Use & waste of form work to face of wall, retaining wall and similar work, (vertical or battered) rough finished surfaces of concrete.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces with Cement plaster (1:4) and mixed with WPC etc complete all as specified and directed. (WPC shall be measured and paid separately)
Cutting into existing manhole for connecting new drain of 200 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required, complete all as specified.
Removing excavated material exc. 50m but not exc. 250m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M&L for 100mm thick plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base complete, all as specified & directed.
Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand specified and directed.
Supply and laying at near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes with modular white cover plate and frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete incl cutting and chasing in stone/brick masonry and making good disturbed surface all as specified and directed by Engr-in-charge for the followings:-
For one light, fan point controlled by one switch
For one 5 Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per item No 81 here in before but for power point wiring using with 2.5 sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge.
S&F Modular switch, one way, 6 Amp 230, 1 module
S&F socket Modular 6 Amp-2/3 pin combined 2 module
S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt
S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt
S&F ceiling rose, surface backlit, three terminal.
S&F modular fan step regulator 120W, 2 module.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply & fix exhaust fans AC single phase 230/ 240 V of size size 450 mm sweep heavy duty with blades and frame and louvers all accessories including making hole in stone /brick wall grouting & making good disturbed surface in all aspects complete with electric connection with suitable copper conductor cable all as specified and directed.
S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs.
S&F double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars including taking down. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate .
S&F testing and commissioning of MCB TPN 63 A ,415 volt 50 Hz,10ka in accordance with IEC 60947- 2 having C-curve characteristics connected with suitable lugs.
S & F of ceiling fan complete with blades, down rod from existing roof / trus to fall ceiling, and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L for GI pipe bracket of size 40 mm dia medium grade of length not less than 1.5 Mtr long and bent to a shape incl fixing wall with 02 Nos MS flate clamp of suitable size incl nut bolt and washers complete all as specified and as directed.
M&L for provn of Earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
M&L for sand cushoning to cable with river sand and punning to provide required cover for UG cables complete. Note :- Only Punned thickness of sand shall be measured & paid.
M&L brick protection cover to electric cable with sub class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm.
Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 25sqmm 3.5 Core nominal cross section in service connections .
M & L for galvanized steel tubing light Grade of 25 mm dia protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Supply and laying GI steel tubing medium grade including all fittings such as Tees, elbow, bends etc for 25 mm bore of pipe laid in trench complete all as specified.
S & F 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
Badri Electricals (BID ID -3309209)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .