Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC 31 A K ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹8.3 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | - | Rejected-Technical L3 |
| 3 | Rejected-Technical JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | R.P.ELECTRONICS L2 | Eastern Commerce L3 | STANDARD ELECTRONICS L1 |
|---|---|---|---|---|---|---|
| 1.00Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split /window type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity | ||||||
| 1.10 | 1.5 TR split type high wall AC machine (rated cooling capacity should not be less than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt) | 7 | Nos | 50,000 ₹3.5 L | 51,200 ₹3.6 L | 40,000 ₹2.8 L |
| 1.20 | 2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt) | 8 | nos | 62,000 ₹5.0 L | 61,200 ₹4.9 L | 55,000 ₹4.4 L |
| 2.00 | Standard installation, testing and commissioning of 1.5/2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge. | 15 | Nos | 2,000 ₹30,000 | 1,800 ₹27,000 | 3,000 ₹45,000 |
| 3.00 | Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.0/1.5/2.0 as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units. | 80 | Mtrs | 300 ₹24,000 | 610 ₹48,800 | 500 ₹40,000 |
| 4.00 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. | 15 | Nos. | 1,000 ₹15,000 | 1,100 ₹16,500 | 1,000 ₹15,000 |
| 5.00 | Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. | 150 | Mtrs | 200 ₹30,000 | 35 ₹5,250 | 80 ₹12,000 |
Tender Value
₹9.5 L
EMD Value
₹18,970
Closing Date
16 Mar 2024, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation, Testing and Commissioning of Split Type Air Conditioning System in different location of High Court of Tripura, Agartala 2nd Call
2024_CEPWD_48320_1
80/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
45 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹18,970
29 May 2026
8 Mar 2024
16 Mar 2024
8 Mar 2024
16 Mar 2024
8 Mar 2024
Amount
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split /window type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS (Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity
1.5 TR split type high wall AC machine (rated cooling capacity should not be less than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt)
2.0 TR split type high wall AC machine (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt)
Standard installation, testing and commissioning of 1.5/2.0 TR split and window type machine including hole cutting, finishing etc as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe beyond 10 ft length of appropriate size as suitable for 1.0/1.5/2.0 as per manufacturer guideline ( 5/8” and 1/4” diameter etc.) for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
R.P.ELECTRONICS
Eastern Commerce
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_49131.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid