Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC GOVT CONTRACTOR VILL GAHAR P O PANJGAIN TEHSIL SADAR DISTT BILASPUR H P | BILASPUR | HIMACHAL PRADESH | 174001 | ₹1.2 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹7.1 L (4.70%)Rejected-Finance JOGINDER NAGAR | JALANDHAR | PUNJAB | 144020 | ₹1.6 Cr+₹7.1 L (4.70%) | L2 | Rejected-Finance Other then Lowest bidder |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical NOT AVAILABLE | NA | NA | 121004 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹99.2 L
EMD Value
₹1.3 L
Closing Date
31 Dec 2019, 5:00 pmClosed
EXECUTIVE ENGINEER
IPH DIVISION CHAUNTRA
Co LIS Div diyaun , Biru , Jamthala Gora in Tehsil Lad Bharol Distt. Mandi H.PSh Co Civil work, Distribution system, pumping machinery and Rising Main
2019_HPIPH_33490_1
8478-8527 dt. 19.12.2019
Open Tender
Civil Works - Water Works
Item Rate
270 days
Lad Bharol
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
EE CHAUNTRA
₹1.3 L
Yes
28 May 2020
19 Dec 2019
1 Jan 2020
19 Dec 2019
31 Dec 2019
19 Dec 2019
Amount
Cutting in earth work in all kind of soil such as pick work, jumper work,chiselling work and then disposing of all surplus excavated with in all lead and lifts.and as per the direction of Engineer-in-charge.
Excavation in foundation and trenches etc. up to all depths and in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out of water, blasting soft or hard rock or chiselling / wedging out of soft/hard rock , where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including shoring, strutting , planking, timbering and dewatering where ever required. Stacking usable and unusable material /soil seperataly , returning the usable soil in 15cm layers by ramming and watering and then dISOsing of all surplus excavated soil/ unusable material as directed within all leads/ lifts complete in all respects within all leads and lifts as per direction of the Engineer-in-charge.
Providing and laying cement concrete 1:4:8 (1cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of from work in foundation and plinth complete in all respect with in all leads and lifts and as per the entire satisfaction of Engineer-in Charge.
Providing and laying cement concrete 1:5:10 (1 cement:5:sand:10 graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining wall/breast wall, the size of plum shall usually be 150mm to 300mm as per the direction of Engineer-in-Charge..
Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and re-inforcement for reinforced concrete work in:-
Foundation , footing basis of columns & the like and mass concrete complete in all respect and as per the direction of Enginer-in-Charge
Wall (any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level complete with in all leads and lifts as per direction of the Engineer-in-Charge.
Suspended floor ,roofs, lendings and shalves and thier suports balconies,beem griders and bressumers and cantiliver upto floor two level complete with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing tor steel reinforcement for R.C.C. work including bending,binding and placing in position complete upto floor two level in all respect complete with in all leads and lifts as per the direction of Engineer-in-Charge.
Providing form work of steel plate 3.15mm thick planking so as to give a rough finish including shuttering, centring, shuttering and propping hight of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for in-situ reinforced concrete and plain concrete work in lintels, beams etc. including all leads and lifts in: and as per the entire satisfaction of Engineer-in Charge.
Foundation , footing basis of columns & the like and mass concrete complete in all respect and as per the direction of Enginer-in-Charge
Vartical surface such as walls (any thickness) portion and the like including attached pillers,buteress plinth and staircases and the like.
Flat surfaces such as soffits of suspended fioors roofs landing and the like . Floors etc up to 200mm in thickness. complete in all respect and as per the entire satisfaction of Engineer-In-Charge.
Edge of slabs & Breaks in floors & walls under 20 cm wide complete in all respect and as per the entire satisfaction of Engineer-In-Charge.
iii) Beams, cantilivers, girders and lintels sides and soffits of beams,beam haunchings cantilivers, girders, bressumers and lintels not exceeding 1 metre in depth
Sloping of batterings surfaces etc.
Providing and fixing inlet pots will mouthed with stainless steel of 150 mm dia as per the direction of Engineer-in-Charge.
Providing and fixing of GMS tube of following dia in walls, floors etc. including tube fittings and making the walls, floors etc. Pipe light grade for inlet,outle and over flow.
125 mm dia (L)
Providing and Fixing of double flanged suing type Cast Iron Sluice Valve of leader/ Kirlosker / Kilburn make and of following dia with flange table - 17 Class - 125 (PN - I) capable of with standing the normal sheet pressure as per IS-5312-1984 with up to date amendements complete in all respect as per the satisfaction of Engineer-in-Charge.
125 MM DIA
Laying , jointing , testing & carrige of galvanized steel tube fittings in trenches of following dia (L) class (Earth work in trenched to be measured and paid or seperately .) complete in all respect with in all leads and lift and as per the direction of Engineer-in-Charge.
150 mm dia (M)
Laying, Jointing testing of HDPE pipes in trenches to required grades as per IS; 4984-1995 latest with up to date amendments of following OD pipes, material grade and class of pipes. The jointing ofpipes should be done by way of butt fusion welding as per relevant IS Code and specification including all fittings and accessories e.g. coupling, TEE's, bends, reducers, screwed adopters, flanged tail pieces etc,complete in all respect.
110 mm PN 4 PE-80
160 mm PN 4 PE-80
Providing and laying cement concrete 1:6:12 (1cement:6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete with in all leads & lifts as per direction of Engineer-in-Charge.
Random rubble masnory/ polygonal rubble masonry (uncoursed/brought to courses) with hard stone of apporved quailty in foundation & plinth including levelling up with cement concrete 1:6:12 (1Cement :6 sand :12greded stone aggregate) in CM 1:6 (1cement : 6sand) complete with in all leads and lifts.
Boulder filling under floor complete with in all leads and lifts.
Brick work using common burnt clay building bricks in super structure above plinth level upto floor two level in cement mortor 1:4 ( 1 cement : 4 sand ) Ist class brick complete with in all leads and lifts.
Providing wood work in frames of door and window 2nd class Deodar wood with in all leads and lift,carrige of material and other incidental charges complete in all respect as per the direction of Enginer-in-charge
Providing and fixing panneled glazed or panneled and glazed shutters for doors, windows and clerestory windows, including black enamelled iron butt hinges with necessary screws 40 mm thick 2nd class deodar wood complete with in all leads & lifts as per direction of Engineer-in-Charge.
Providing & fixing M.S. grills of required pattern in wooden frame of window etc. with M.S. flats, square or round bars with round headed bolts and nuts by screws plain grill complete with in all leads and lifts..
Cement concrete flooring 1:2:4 (1cement : 2sand : 4 graded stone aggregate 20mm nominla size) laid in one layer finished with a floating coat of neat cement 40mm thick complete with in all leads and lifts.
6mm thick cement plaster to ceiling in cement mortar 1:3 (1 cement:3 sand)
15 mm cement plaster in single coat on rough side of brick/ concrete/ stone wall for interior plastering upto floor two level including arrises internal rounded angles, chamfers and or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortor 1:6 (1cement:6sand) complete with in all leads & lifts as per direction of Engineer-in-Charge.
Flushing pointing on brick work with cement mortor 1:3 (1cement :3sand).
White washing with lime on un-decorated wall surfaces (with two coats) to give an even shade including thoroughty brooming the surface to remove all dirt,dust,mortor dirt and other foreign matter.
Applying priming on new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil, grease, dust and other foreign matter, sand preparing and knotting. Ready mixed paint brushing wood primer pink.
Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give even shade including cleaning the surface of dust and other foreign matter, sand preparing and stopping with enamel paint other than white.
Providing and fixing oxidized M.S. sliding dooor bolts with nuts and screws etc. complete 300x16mm complete with in all leads & lifts as per direction of Engineer-in-Charge.
Providing and fixing anodised M.S. Tower bolts (Barrel type) with necessary screws etc.complete .
Providing and fixing Oxidized M S Handle with necessary screws etc complete. 125 mm
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand:6graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth.
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed of dry brick /stone aggregate 40mm nominal size) well remmed and consolidated and grouted with fine sand including preparation of ground.
Half brick masonry in common brunt clay building bricks in cement mortor 1:4 ( 1 cement:4 sand ) 2class bricks complete with in all leads and lifts.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point Group C
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper condu
i) 2x1.50 Sq. mm.
ii) 2x2.50 Sq. mm.
(a) Supplying and fixing 3 pin 5/6 amps. Socket outlet on the exists switch box/covers including connections etc. as required.
(b) Supplying and fixing 2 way 5/6 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required.
(a) Supplying and fixing 3 pin 15/16 amps. Socket outlet on the exists switch box/covers including connections etc. as required.
(b) Supplying and fixing 15/16 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required.
(a)Supplying and fixing wooden box of following size (nominal) on surface or recess with suitable size of phenolic laminated sheet cover of in front as required.
(b) 203 mm.x152 mm.x 60 mm. deep
Providing and Supplying CFL 1 x 23 watt of reputed make in all leads and lifts.
Providing and Supplying of CFL 1 x 5 watt in all of reputed make in leads and lifts.
Supplying and Fixing 5 Amps to 32 Amps rating, 240 Volts, L series miniature circuit breaker of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required Cat - A. (Single Pole)
Supplying and fixing ceiling rose on existing junction box /wooden block i/c connections etc as required.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Single door-16 way
Supplying and fixing following rating ,double pole ,240 watts ,isolator in the existing MCB DP complete with connections (testing and commissioning etc. as required (63 amp. CAT A
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:-
Ceiling Fan 1400 mm sweep, Category-A
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required.
1 x28 watt-FTL(T5) (Category-A)
P/F street light with CFL 65 Watts for pump house and Jack well complete in all respect.
Providing and fixing two core service wire 6 sqm thick
Providing , laying, fixing, jointing and testing in trenches steel pipe of following dia meters confirming to ISO 3183-2007, pipe grade API 5-L L-290 or X-42 (latest with upto date amendments) having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
300 mm dia , (ISO 3183-2007), Wall thickness 4..00 mm, F.T=5 L-290
300 mm dia , (ISO 3183-2007) Wall thickness 4.40 mm, F.T=17
Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Steel pipes of following dia meters confirming to ISO 3183-2007, pipe grade API 5 L (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
300 mm dia , (ISO 3183-2007), L-5,Wall thickness 4.40 mm, L-290x42
300 mm dia , (ISO 3183-2007), L-5,Wall thickness 4.40 mm, L-290x42
PUMPING MACHINERY Raw water stage: Providing and installation of suitable raw water submersible pumpset type KRT capable of handling 6000 PPM turbidity of KSB make conforming to latest BIS IS 8034:1989 code. The pump shall be fitted with single vane impeller of suitable alloy for handling raw water as per IS 5669-1970 having oil/grease packed bearings and stainless steel shaft, wound stator on motor side with shaft protection sleeves on pump side ensuring better life for shaft . The impeller of pump shall be directly mounted on extended submersible sq cage motor shaft conf to BIS 9238-1979 with up to date amendments of 1450 (N) RPM, totally dust and weather proof with detach able pump casing for easy inspection with double mechanical seal, grease/ oil lubricated bearings and provided with stainless steel thrust bearing plate to withstand vertical loads with minimum wear and tear,It should be fitted with device to take up expanion of water on heating of motor & suitable for operation on 415 +/- 10% volts 3 Phase 50 C/S AC supply. The power of motor should be at least 10% in excess of maximum power required by the pump in complete operating range with mounting stand/ duck foot bend, steel guide wire with mounting hook, lowering chain and standard accessories as supplied by the manufacturers complete, suitable for fulfilling the following requirements:- Discharge: 27.81 LPS for each pump set Total head in Mts. 26.05 mtrs. Length of column pipe 30 Rmtr. Dia of R/Main 300 mm Pumping hours 20 Hours Limits of total head in which the pump/ motor is reqd. to operate. (+)10% & (-) 15%
Supply and erection of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing and fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections including installation. The drawing of panel board shall be subject to approval of Engineer in charge.
c) ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
f) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
g) Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitaible range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
h) Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations.
i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference.
j) Single phase preventor of reputed make & suitable capacity
k) Supply and erection of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader/ Kartar of approved make of suitable size Cast iron double flanged sluice valve having size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of rising main for withstanding nominal seat pressure as per BIS.
Providing and Laying suitable size copper PVC insulated armoured power 3.1/2 core cable confirming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing and Laying PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from OCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply and erection of standarad make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Providing and Laying Delivery pipe considering site requirements,NPSH required & available having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 , nuts & bolts as per 1364-1983 & special from pump set to ground level i/c common header and up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
P/L column pipe considering site requirments, NPSH required & abailable & common header having area equel two times the area of delivery branch of pump including tapers, flanges, rubber gaskests, 3mm thick as per BSI-2712-1978 nuts & boltes as per 1364-1983 & special up to 5mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer -in-charge. The pipes shall be capable of withstanding 1.5 times the totel presure in item no. Ie(ii).
Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel base plate (base plate to be from the manufacturer of the pumping unit only) to slip ring/ squirrel cage screen protected drip proof induction motor /motors of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: Total head:- 154.45 Mtrs Static head 148 Mtr a) LWL in sump well (h) 627.45 metre b) Shaft level 627.00 metre RL of the heightest delivery point 775 metre d) Suction lift +ve metre. RL of pump house 626.55Mtrs Rising main a) Length 920 mtr b) Dia 300 mm Pumping hours 20 Hours Altitude of installation above MSL= 1020 metre Characterstics of water Clear cold water with turbidity up to 50 PPM. a) Temperature 20 degree centigrade. (Note: One pump set to act as stand by)
Supply and erection of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No. 55 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities
c) ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments
b) Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per IS:2516:1977 with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end.
c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482 (latest edition)
f) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
g) Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitaible range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
h) Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations.
i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference.
Change over switch of reputed make & suitable capacity.
j) Single phase preventor of reputed make & suitable capacity
Providing double flanged CI sluice valve PN1 of Leader/BHEL/Kirlosker/GLEd/Kilburn Fourses / Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with upto date ammendments
Providng double flanged cast steel sluice valves ASA-300 of leader/BHEL Kirlosker/Kilburn GLED/ fourses make and one step higher then delivery line of pump and capable of withstanding the normal seat pressure and as per BIS standards with upto date ammdnements
Providing double flanged swing type cast steel valve, ASA-300 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Fourses make and having bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendments)
Providing double flanged cast steel reflux valves class ASA-300 of Leader/ BHEL/ KILROSKER/ KILBURN /GLED/ FOURSES make and of 100 mm dia having bye pass arrangements for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
(a) Motor side (From switch to starter and starter to motor)
(b) Supply side (From Meter of HPSEB to bus bar and switch)
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply and erection of standarad make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all items 50.01 to 50.10 and 61.01 to 62.08 i/c cost of TEEs,Bends,tapes and any other fittings required as per site conditions and as per direction of Engineer in Charge.
Gaurav Thakur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .