Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance KALARIKKAPARAMBIL BRAHMAPURAM P O AMBALAMUGAL ERNAKULAM 682 303 | ERNAKULAM | ERNAKULAM | KERALA | 682303 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
26 Aug 2025, 4:05 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ENGINEER (PROJECTS)
KEL MAMALA KOCHI
Department of Tourism-Modification of Reception Area in Thycaud Guest House, Thiruvananthapuram
2025_KEL_788494_1
KRO/BDC/2086/2025
Open Tender
Civil Works - Buildings
Item Rate
KEL MAMALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,900
₹50,000
Yes
29 Aug 2025
19 Aug 2025
27 Aug 2025
19 Aug 2025
26 Aug 2025
19 Aug 2025
19 Aug 2025 - 26 Aug 2025
Amount
CIVIL WORKS
15.2.2 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix)
15.23.2 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm
15.3 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.12.2 Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area beyond 3 sq. metres
15.57 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
4.2.3 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
6.1.2 Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.91 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13.4.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.51.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces:Two coats
13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
9.1.2 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood
22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
OD100287/2025-2026 Providing and fixing glazed windows with 8mm thick clear toughened glass with Hindalco Totalis Alu system or equivalent for sliding windows etc complete as directed by the Architect.
OD100298/2025-2026 Providing and laying vitrified floor tiles in 2400x1200 mm x9mm size to be approved by the architect) with water absorption less than 0.08% and conforming to IS : 15622, ISO 10545 - 7 class 3 or above, of approved make (Nexion onice persiano lappatto matt finish or naturale finish or equivalent or Nexion Travertine Veincut Beige Lappato Matt or equivalent) , in all colours and shades, laid on suitable tile adhesive approved by the architect, including grouting the joints with epoxy joint filling of matching pigments and 3mm spacing etc., complete.
11.48.4 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 1000x1000 mm
8.10.2 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade
12.45.3 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
OD100402/2025-2026 Providing and fixing PVC Vox false ceiling
OD100663/2025-2026 Supplying and applying 15 to 20 mm thick lime plaster, as per the following (a).Well graded, silt free sand is got. The grain size will depend on the plaster thickness.(b) Freshly burnt fat lime is got and tested for CaO content. It should be more than 90%. The freshly burnt lime should not be stored and slaked immediately.(c) The lime is slaked with water slowly on a platform till it turns to powder form and then it is pushed into the slaking tank. Safety precautions are required as it is an exothermic reaction.(d) It is filtered with 1000 micron sieve and stored under water for atleast 15 to 20 days.(e) It is mixed with sand in 1:3 proportion by volume using a roller mixer / grinder / traditional bullock drawn "ghaani" for 120 to 150 revolutions.(f) It is then packed in double lined airtight bags and stored under tarpaulin in shaded area for atleast one week.(g) Additives like brick dust (passing 100 microns)/fly ash / or any other pozzolonic additive, jaggery syrup/ mollases, saras, bel fruit
OD Modified from 25.3 Providing and fixing glazed door with 5mm+5mm thick clear toughened glass with 1.5mm PVB laminated door with stainless steel Dorma Kaba (CROWN) fittings such as BTS floor spring, pivot set at top and bottom, Top & Bottom patches, Corner locks with EPC 60mm, 300mm handles, etc complete as directed by the Engineering-in-Charge.
OD Modified from 25.3 Supply of decorative sandwitch glass, with section of 6mm extra clear toughened glass+ 0.79mm EVA+ TF044+ 0.79mm EVA+ 6mm extra clear toughened glass. Glass will be extra clear Toughened of (Saint Gobain / equivalent), TF044 of approved pattern by the architect. Rate includes toughening and sandwiching cost, handling, transportation, insurance, wastage complete. including aluminium support system thin profile sections on all four sides of all glasses and one horizontal section of size 50mm x 100mm section, Installation complete."
OD0001//2025-2026 Supply and installation of Wood plastic Composite in wall paneling including fixing to MS frame with necessary screws complete (base of the MS frame to be measured and paid separately.)
FURNITURES
OD 001/2025-2026 Supply of two seater sofa with metal/teak wood leg with PU polish (2 coat sealer + 2 coat polish) and sturdy support with premium artificial leathertte (Brand- Auckland /equivalent) and high density memory foam , as per 3d views and reference images approved by Architect in charge (Brand Riyawood or equivalent)
OD002/2025-2026 Supply of single seater sofa with metal/teak wood leg with PU polish (2 coat sealer + 2 coat polish) and sturdy support with premium artificial leathertte (Brand- Auckland /equivalent) and high density memory foam , as per 3d views and reference images approved by Architect in charge (Brand Riyawood or equivalent)
OD003/2025-2026 "Supply of round coffee table of 80 cm diameter and 50 cm height with dark colour natural marble top and sleek powder coated metal legs as per 3d views and reference image, to be approved by the Architect in charge"
OD004/2025-2026 "Supply of round coffee table of 50 cm diameter and 50 cm height with dark colour natural marble top and sleek powder coated metal legs as per 3d views and reference image, to be approved by the Architect in charge"
OD005/2025-2026 Supply of single seater(in front of reception counter) rotatable with metal/teak wood leg with PU polish (2 coat sealer + 2 coat polish) and sturdy support with premium artificial leathertte (Brand- Auckland /equivalent) and high density memory foam , as per 3d views and reference images (Brand Riyawood or equivalent)
OD006/2025-2026 "Supply of console table od size 210 (L) X 50(W) X 90(H) cms with dark colour natural marble top and poweder coated sleek and sturdy metal legs, as per 3d views and reference images (Brand Riyawood or equivalent)"
OD007/2025-2026 Supply and installation of Bell Desk - of size 90cm (L) X 50 cm (W) X 100 cm (H) - using plywood of specification- IS 710 BWP, fire retardant, E0 calibrated plywood of thickness 16mm , insides are finished with 1mm laminated of approved colour with matching edge band- Counter top , front and sides are cladded with black Nero Marquina marble slab of thickness minimum 18mm using low VOC PU epoxy hybrid adhesive. (make Roff or equivalent). Top horizontal and front marble slabs are to be joined in 45 degrees and should have a smooth finish. shelves and drawers with hinges and handles.
OD008/2025-2026 Supply and installation of Reception counter - of size 600cm (L) X 80 cm (W) X 75 cm (H) -using plywood of specification- IS 710 BWP, fire retardant, E0 calibrated plywood of thickness 16mm , insides are finished with 1mm laminated of approved colour with matching edge band- Counter top , front and right sides are cladded with black Nero Marquina marble slab of thickness mininum 18mm using low VOC PU epoxy hybrid adhesive. (make Roff or equivalent). Top horizontal and front inclined marble slabs are to be joined in 45 degrees and should have a smooth finish. shelves and drwers with hinges and handles.
OD009/2025-2026 Providing decorative Ceramic Planters pots of size 57*110cms, 45kg weight with decorations or sculptures to be approved by the Architect/ Engineer in charge
OD0011/2025-2026 Abstract original art work in bold colours on canvas - medium - oil or acrylic is finished with thin wooden frames or floater frames of size approximately .9M X 1.5 M ( as approved by Architect in charge)
ELECTRICAL WORK
OD100128/2025-2026 Dismantling of existing electrical installations in required area and stacking it in appropriate area as per the instruction of department in charge
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.54.2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.9 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.53.2 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable
90.10.1.2 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amp
OD100554/2025-2026 Supply and fixing RJ45 Wire Connector
OD100555/2025-2026 Supply and fixing D-link Key stone and face plate with RJ45 Wire Connector
OD100585/2025-2026 Supply and fixing recess mounting 6W LED Circle (Round) fittings including frame as required. (M/s Crompton, Philips ore equivelant Parroved make)
OD100586/2025-2026 Supply and fixing recess mounting 15W LED Square type fittings including frame as required
DECORATIVE HANGING LIGHT
OD0041/2025-2026 Supply and Installation of Lamp LED, Size L 900mmx W50mmx H 1000 mm, Finish antique brass, material metal + acrylic, warm light Brand changi/ equivalent
OD0042/2025-2026 Supply, Installation, testing and commissioning of Double height lobby Lamp LED, Size 1 no 1200mm dia + 1 no 800mm dia, height 1200 mm, finish antique brass, material metal + acryllic, warm light brand changi or equivalent
OD0043/2025-2026 Supply, Installation, testing and commissioning of Lamp LED, Size L 900mmx W50mmx H 1000 mm, Finish antique brass, material metal + acrylic, warm light Brand changi/ equivalent
OD0044/2025-2026 Supply, Installation, testing and commissioning of profile light - profile 20mmx10mm- light led, colour warm, strip 24w, driver 2A etc as requir
OD0045/2025-2026 Supply, Installation, testing and commissioning of Decorative wall washers for glass partition
EXCLUSIVE OF GST
Note: All of the market item rates should be submitted by orginal bill during execution
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
9.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
10.DELUXE MULTI SURFACE PAINT SYSTEM: Make: JOTUN, Asian, Berger, Nerolas or eq. in the order of pref.
14.VITRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
saaj constructions (BID ID -2304892)
RAJESH N D (BID ID -2302821)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .