Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L -1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L -1 | Accepted-AOC Lowest 1 |
| 2 | L -2₹1.9 Cr+₹6.0 L (3.36%)Rejected-Finance PLOT NO 113 GURUSANGAT DARBAR ROAD SINDHI COLONY KHAMLA NAGPUR 440025 | NAGPUR | MAHARASHTRA | 440025 | ₹1.9 Cr+₹6.0 L (3.36%) | L -2 | Rejected-Finance Lowest 2 |
| 3 | L -3₹1.9 Cr+₹6.1 L (3.42%)Rejected-Finance | ₹1.9 Cr+₹6.1 L (3.42%) | L -3 | Rejected-Finance Lowest 3 |
| 4 | L -4₹1.9 Cr+₹8.9 L (4.97%)Rejected-Finance 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | ₹1.9 Cr+₹8.9 L (4.97%) | L -4 | Rejected-Finance Lowest 4 |
| 5 | L -5₹1.9 Cr+₹9.7 L (5.43%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹1.9 Cr+₹9.7 L (5.43%) | L -5 | Rejected-Finance Lowest 5 |
Tender Value
Refer Docs
EMD Value
₹4.2 L
Closing Date
25 Nov 2020, 6:00 pmClosed
AGM(E-E)-II
O/o of Airports Authority of India, R. B. Airport, Bhopal - 462036
ARMO of E and M Installations of Operational Area, Residential Colony, MSSR and GLF at R. B. Airport, Bhopal for the year 2020-22.
2020_AAI_59142_1
AAI/BPL/ENGG(E)/NIT-06/2020-21
Open Tender
AMC/ Maintenance Contracts
Works
720 days
R.B. Airport
Please refer Tender documents.
19 documents required · 19 mandatory
₹1,120
Yes
₹4.2 L
Yes
8 Feb 2021
9 Nov 2020
27 Nov 2020
10 Nov 2020
25 Nov 2020
10 Nov 2020
10 Nov 2020 - 20 Nov 2020
Amount
Annual Operation of 320 KVA D.G.Set of Old Power House & MSSR and Maintenance of Electrical & Mechanical installations of Old Power House, ATC Building, Fire Station, MT Workshop, Nav-Aids, GLF Installations, Perimeter lighting, Outer Marker, MSSR, Street light, Pump House, Residential colony etc. by deploying adequate manpower as per special conditions of contract.
Provision of additional hour required for operations due to delay in flight, emergency, major maintenance works. Beyond the scope of item no. 1 on daily basis.
Skilled
Un-skilled
Inspection, servicing and testing of 3 Pole, 800A, 11KV, HT Vaccum circuit Breakers (2 Nos. VCB ) (Make: Crompton Greaves) installed at Old power house at Bhopal Airport, including carrying out the following tests & preventive maintenance alongwith submission of the test reports. (a) General inspection (b) Wiring check including control circuit and indications (c) IR test between poles to poles, between poles to earth in closed condition and between pole to pole in open condition. (d) Continuity of power contacts. (e) Continuity of auxiliary contacts (f) Resistance measurement of tripping coil (g) Closing, tripping and inter- locking testing (h) Tripping through relay operation
First Year
Second Year
Calibration of 11 KV HT panel of relays of Crompton Greaves make (01 Over current relay + Earth fault relay, type-CGI 14 N) complete by digital relay testing set of the Airport power house. - 2 Nos.
First Year
Second Year
Dehydration and filtration of transformer oil at AAI site including testing the BDV before and after testing and submission of test reports etc. as required for following Transformers.
500 KVA Transformer (Make: Voltamp)
First Year
Second Year
630 KVA Transformer (Make: Voltamp)
First Year
Second Year
Supply and topping of transformer oil (Tested).
Rewinding of the following Fans & Pumps with copper wire of required size including less for dismantled copper wire, alignment, bearing etc. complete as reqd.
Ceiling Fans 48", 230V
Exhaust Fans/ Air cooler
1 HP - 2 HP Submersible Pump Motor
3 HP - 5 HP Mono block Pump Motor
7.5 HP - 10 HP Mono block Pump Motor
4 HP Submersible Pump Motor
7.5 HP Submersible Pump Motor
Painting of following poles in 2 coats by using Aluminium paint of approved make (Asian / Berger) including pole boxes, cleaning of surface etc., as required including rewriting the identification Sl.No.
50 mm Gl pipe pole of length not exceeding 3 Mt.
75 mm Gl pipe pole of length not exceeding 3 Mt.
Tubular street light poles of length not exceeding 11 Mt.
Annual Servicing of CCR of 4KW to 30 KW capacity of NASU make by OEM.The scope of item includes inspection of all the parts of CCR, servicing, checking of wiring for healthiness etc. and submission of test reports etc, complete as required.
First Year
Second Year
Spray Painting of sheet metal enclosures of electrical panels inside the power house, Pump room & ATC building & terminal building including cleaning the surface and one coats of grey or any other color of make (Asian / Berger) including rewriting the identification the circuit, Protecting and covering the electrical accessories during painting and removing after work is over etc., as reqd.
Painting of sheet metal enclosures of electrical equipments such as feeder pillars, distribution boards, electrical panel, frame etc. including cleaning the surface and one coat of grey or any other color of make (Asian / Berger) including rewriting the identification the circuit, Protecting and covering the electrical accessories during painting and removing after work is over etc., as reqd.
Supply of 200 W, 6.6 Amp Bi pin Halogen Lamp suitable for for AMA Make PAPI fitting (Make: OSRAM/Philips/Youyang or as recommended by OEM)
Supply of 200 W, 6.6 Amp Lamp suitable for CAT 1, Threshold, SAPL & End light fittings (Make: OSRAM/Philips/Youyang or as recommended by OEM)
Supply of 150 W, 6.6 Amp Bi pin Halogen Lamp for Runway Edge light fitting (Make: Phillips /OSRAM/Youyang or as recommended by OEM)
Supply of 105 W, 6.6 Amp Bi pin Halogen Lamp for inset fitting (Make: Osram /Philips/Youyang or as recommended by OEM)
Supply of Lamp Holder for 200 W, 6.6 Amp Bi pin Halogen Lamp suitable for AMA Make PAPI fitting.
Supply of driver for Retro-Fit conversion of existing LED type way light fitting. Each fitting is to be illuminated by a single driver & by using single isolating transformer of suitable size. The Driver should work on runway / taxiway current varying from 2.8 to 6.6 Amp complete etc. as required.
Supply of Neoprene type Inner Gasket for Runway inset fitting of YOUYANG Make
Supply of Neoprene type Outer Gasket for Runway inset fitting of YOUYANG Make
Supply of 200 Watts, 6.6/6.6 Amps 5 kV grade 50 Hz Isolating transformers, series type encapsulated in neoprene tube rubber with primary and secondary leads as specified in particular specifications.
Supply of 100 Watts, 6.6/6.6 Amps 5 kV grade 50 Hz Isolating transformers, series type encapsulated in neoprene tube rubber with primary and secondary leads as specified in particular specifications.
Supply of 6.0 Sq.mm Plug and Receptacle of Type-I Class 'B' connector and suitable for field attachment with 5 kV grade PVC insulated, PVC sheathed single core Runway copper conductor cable complete as required.
Supply of 16.0 Sq.mm Plug and Receptacle of Type-I Class 'B' connector and suitable for field attachment with 5 kV grade PVC insulated, PVC sheathed single core Runway copper conductor cable complete as required.
Supply of driver for Retro-Fit conversion of existing signage board. Each board having length from 800mm up to 3000mm should be illuminated by a single driver & by using single isolating transformer of suitable size. The entire sign board should have inbuilt dual circuit to work on main & Stand by Circuits. The Driver should work on runway current on runway current varying from 2.8 to 6.6 Amp & should have uniform brightness across the entire range of current variation from 2.8 Amp to 6.6 Amp. The Driver should be able to drive LED strips of 0.5 Watts Osram LED's assembled on aluminium PCB of size 700mm X 200mm and having 11 LED's per PCB for boards. From 5 strips to 20 strips
Supply of Red filter for Runway End light fittings of YOUYANG make
Supply of 360° Outer Clear Lens (Dome) for Runway Edge Light Fitting (YOUYANG Make).
Supply of Breakable couplings for Signage Board.
Supply of heat shrinkable jointing kit of 6 sq. mm size, single core copper conductor, 5 KV grade for Airfield lighting cable complete etc. as required.
Supply of 5 KV grade 6 Sq.mm size unarmered single core airfield lighting cable with Stranded Annealed Plain Copper Conductor, Underground, Unscreened, Unarmored, PVC Insulated & PVC Sheathed completed etc. as required.
Supply of PAPI Check Stick Base Plate complete with suitable size of nut bolts and other accessories complete etc. as required.
Supply of 6.0 Sq.mm Plug and Receptacle of Type-I Class 'B' connector and suitable field attachment with 5 KV grade XLP insulated PE Sheathed single core screened copper conductor cable as required.
Supply of 16.0 Sq.mm Plug and Receptacle of Type-I Class 'B' connector and suitable field attachment with 5 KV grade XLP insulated PE Sheathed single core screened copper conductor cable as required.
CPWD Schedule of rates DSR-2018 (Electrical) items of Rs. 1,00,000/- - Chapter 01 to 10 & 14 The rate shall be quoted for this item as per examples given below- • Please refer clause 43 of GTT page No. GTT - 10 before quoting rates for this item. • If bidder wants to quote the rates at par with rates of DSR-2018 (E & M), then bidder has to quote 1.00 in the rate column. • If bidder wants to quote the rates 10% above the rates of DSR- 2018 (E & M), then bidder has to quote 1.10 in the rate column. • If bidder wants to quote the rates 10% below the rates of DSR- 2018 (E & M), then bidder has to quote 0.90 in the rate column.
M/s BHARAT ELECTRIC, NAGPUR
S. N ELECTRICALS
Ascent Electrification Engineers
Manish Electricals
CIS GLOBAL INFRATECH PRIVATE LIMITED
PAN POLAR ENGINEERS PVT. LTD.
NATIONAL SAFETY ENGINEERS
KSHARMAELECTRICALS
EFFECTIVE ENTERPRISES
R. D. ENGINEERS
JAI ENTERPRISES
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .