Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC PARUTHIYEZHATHU HOUSE MULAVUKAD P O NORTH ERNAKULAM 682 504 | ERNAKULAM | KERALA | 682504 | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹11.0 L+₹51,456 (4.92%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹11.3 L+₹82,726 (7.91%)Rejected-Finance 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L3 | Rejected-Finance Other than Lowest Tenderer | |
| 4 | L4₹11.3 L+₹87,981 (8.41%)Rejected-Finance ITTIKUNNATH X 386 KOREPARAMBIL ROAD NJARACKAL ERNAKULAM 682505 | ERNAKULAM | ERNAKULAM | KERALA | 682505 | L4 | Rejected-Finance Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | St George Engineering Works L3 | AB CONSTRUCTIONS L2 | HIGH TECH ENGINEERS AND CO L4 | GOLDEN EYE BUILDERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking up carefully defective switch /socket / regulator/ bell/ bell push/ holder/ ceiling rose/ MCB/ light fittings etc. any size/ make complete all as specified and as directed. | 3,138 | Each Job | 10 ₹31,380 | 20 ₹62,760 | 10 ₹31,380 | 3 ₹9,414 Lowest |
| 2.00 | Supply and fix switch piano, flush type, single pole, one way, 6 Amps, complete all as specified and as directed. | 1,000 | Each | 40 ₹40,000 | 30 ₹30,000 Lowest | 50 ₹50,000 | 75 ₹75,000 |
| 3.00 | Supply and fix switch piano, flush type, single pole, two way, 10 Amps, complete all as specified and as directed. | 40 | Each | 45 ₹1,800 | 35 ₹1,400 | 30 ₹1,200 Lowest | 40 ₹1,600 |
| 4.00 | Supply and fix switch socket combination outlet multipurpose 2 in 1, 5 pin, 6 Amps and 2 pin 6 Amps flush type complete all as specified and as directed. | 250 | Each | 70 ₹17,500 Lowest | 190 ₹47,500 | 150 ₹37,500 | 195 ₹48,750 |
| 5.00 | Supply and fix switch socket combination outlet multipurpose , 6 Amps and 16 Amps flush type complete all as specified and as directed. | 220 | Each | 90 ₹19,800 Lowest | 280 ₹61,600 | 245 ₹53,900 | 205 ₹45,100 |
| 6.00 | Supply and fix socket outlet multipurpose 2 in 1, 5 pin, 5 Amps and 2 pin 6 Amps complete all as specified and as directed. | 100 | Each | 190 ₹19,000 | 80 ₹8,000 | 65 ₹6,500 Lowest | 90 ₹9,000 |
| 7.00 | Supply and fix socket outlet multipurpose 6 Amps and 16 Amps complete all as specified and as directed. | 110 | Each | 220 ₹24,200 | 120 ₹13,200 Lowest | 190 ₹20,900 | 150 ₹16,500 |
| 8.00 | Supply and fix switch piano, flush type, single pole, one way, 16 Amps, complete all as specified and as directed. | 110 | Each | 160 ₹17,600 | 140 ₹15,400 | 70 ₹7,700 Lowest | 155 ₹17,050 |
| 9.00 | Supply and fix ceiling rose PVC poly carbonate, isolated body with two to three terminals including connection, all as specified and as directed. | 55 | Each | 60 ₹3,300 | 30 ₹1,650 Lowest | 80 ₹4,400 | 55 ₹3,025 |
| 10.00 | Supply and fix lamp holder, PVC / Poly carbonate type, with cord grip cap suitable for pendent/ batten/ angle fittings complete all as specified and as directed. | 160 | Each | 55 ₹8,800 | 35 ₹5,600 Lowest | 45 ₹7,200 | 95 ₹15,200 |
Tender Value
₹14.3 L
EMD Value
₹28,500
Closing Date
12 Aug 2025, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
REPAIR/ MAINT AND REPLACEMENT OF UNSERVICEABLE LIGHT FITTINGS, WIRING, BLDG SECURITY LIGHTS, SWITCHES, DBs, MCBs, AND CONNECTED ITEMS AT SECTOR III, IV IN SMA RAMESWARAM, PAMPA VIHAR I AND II, DAD RESIDENATIAL COMPLEX PALLURUTHY UNDER GE FORT KOCHI
2025_MES_720554_1
8242/E8_GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹28,500
Yes
29 Sept 2025
15 Jul 2025
19 Aug 2025
15 Jul 2025
12 Aug 2025
29 Jul 2025
Amount
Taking up carefully defective switch /socket / regulator/ bell/ bell push/ holder/ ceiling rose/ MCB/ light fittings etc. any size/ make complete all as specified and as directed.
Supply and fix switch piano, flush type, single pole, one way, 6 Amps, complete all as specified and as directed.
Supply and fix switch piano, flush type, single pole, two way, 10 Amps, complete all as specified and as directed.
Supply and fix switch socket combination outlet multipurpose 2 in 1, 5 pin, 6 Amps and 2 pin 6 Amps flush type complete all as specified and as directed.
Supply and fix switch socket combination outlet multipurpose , 6 Amps and 16 Amps flush type complete all as specified and as directed.
Supply and fix socket outlet multipurpose 2 in 1, 5 pin, 5 Amps and 2 pin 6 Amps complete all as specified and as directed.
Supply and fix socket outlet multipurpose 6 Amps and 16 Amps complete all as specified and as directed.
Supply and fix switch piano, flush type, single pole, one way, 16 Amps, complete all as specified and as directed.
Supply and fix ceiling rose PVC poly carbonate, isolated body with two to three terminals including connection, all as specified and as directed.
Supply and fix lamp holder, PVC / Poly carbonate type, with cord grip cap suitable for pendent/ batten/ angle fittings complete all as specified and as directed.
Supply and fix Bell push, flush type, 5 Amps complete all as specified and as directed.
Supply and fix bell Ding Dong AC. 230 volts, single pole complete all as specified and as directed.
Supply and fix Modular switch 1 way 6A,1 module complete all as specified and as directed.
Supply and fix Modular switch 1 way 16A, 1 module complete all as specified and as directed.
Supply and fix Modular Bell push 6A 1 module complete all as specified and as directed.
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module,, complete all as specified and as directed.
Supply and fix MCB SP 6 to 32 Amps, 240 Volt, having breaking capacity 10 KA, B curve with visual indication complete all as specified and as directed.
Supply and fix MCB SPN, 32 Amps, 240 Volt, having breaking capacity 10 KA, C curve complete all as specified and as directed.
Supply and fix MCB TPN, 40 to 100 Amps, 415 Volt, having breaking capacity 10 KA, B curve complete all as specified and as directed.
Supply and fixing round shape 12 Watt, 220 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fix surface mounted LED integrated batten four feet long, 22/20 Watt comprises of polycarbonate housing, integrated electronic driver, diffuser etc. and all accessories pre-wired including connecting up complete all as specified and as directed.
Supply and fix surface mounted LED fitting 2 feet, 9/10 Watt comprises of polycarbonate housing, integrated electronic driver, diffuser etc. and all accessories pre-wired including connecting up complete all as specified and as directed.
Supply and fix 2 pin type LED lamp B22 10 watts suitable for existing angle/ batten holder comprising of high pressure die cast aluminium housing, polycarbonate cover, etc. complete all specified and as directed.
Supply and fix Decorative wall light fixture made up of Polycarbonate 9 watts comprises of polycarbonate housing, high efficiency diffuser polycarbonate cover, Lamp 9 watts warm white, etc. and all accessories pre-wired including connecting up complete all as specified and as directed.
Supply and fix LED building security light fitting 30 watts protection comprises of a pressure die, cast aluminium housing, polycarbonate cover, high power LED with lenses, 10KV built-in-surge protection, electronic driver, etc. and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 25 mm bore light grade GI tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means flat iron clamps, nuts, bolts and washers etc. complete all as specified and as directed.
Supply and fixing in repairs 1.6mm thick Hylum sheet, cut to suitable size, cutting holes for fixing switches, regulators, sockets etc. complete all as specified and as directed.
Supply and fixing of MCB DB double door made of sheet steel phosphates, powder coated painted with bus bar, neutral link, earth bar and rail double door type SPN 240 volts 8 way fixed concealed/ recessed having IP-43 protection including cement mortar 1:3 for making good to disturbed surface match with existing surface including colouring complete, all as specified and as directed.
`-Ditto- all as per item No 28 above but 240 Volts SPN 12 way
`-Ditto- all as per item No 28 above but 240 Volts SPN 4 way
`-Ditto- all as per item No 28 above but 415 Volts TPN 4 way
Supply and fixing in repairs sheet metal enclosure with two pin and earth plug and socket complete with one MCB 20 Amps single pole having breaking capacity 10 kA complete all as specified and as directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3mm thick, buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr normal ground level, connected to GI strip 32x6mm size as earth lead by means of bolts, nuts , check nuts and washers of GI or steel as shown in electrical plate No 3 connected to earthing test point, testing, (Earthing shall be interconnected) including necessary excavation, 50mm thick RCC 1:2:4 cover reinforced with 8mm TMT bars 100 mm c/c in both ways at, salt, charcoal, removal of surplus soil etc. including taking out old earth plate complete all as specified and as directed.
Material and Labour for inspecting all ceiling fans including down rod, S or D hook, tightening of screws/pins, capacitor, any other loose parts, renewing burnt wires, wrapping all joints with insulation tape complete, and DBs including tightening of screws, MCBs, any other loose parts, replacing burnt wires, wrapping all joints with insulation tape and registering details all as specified and as directed. Notes: (i) Two/ three ceiling fans will be in a dwelling unit. (ii) Common DB/individual DB of each Qtrs shall shall be included in the quoted rate. (iii) Meter boards/connections also deemed to be included in the quoted rate.
Material and Labour for pouring of salted water in to each earth pit through water pipe, minimum of 100 Litres dissolved with 5 Kgs of common salt to each earth pits / electrodes at various sub stations / buildings for improving the earth conditions, all as specified and as directed. Note: - The contractor has to arrange water and transport to various sub stations / installations for the above purpose and Testing of Earth resistance of Electrical earthings of various types, at various Buildings/Sub stations by using digital type Electrical earth Tester instruments, registering the test results in the prescribed Performa including cleaning the earth chamber, identifying the earth lead wire, testing and writing by paint the test results, date of testing etc. on the chambers all as specified and as directed. (The job/test will be carried out in the presence of department staff and details registered)
Taking down copper/aluminium point wiring (light, fan, socket etc) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, lamp holder etc. re-fixing removed fittings and making good the disturbed surface of wall to match with existing surface complete all as specified and as directed.
Taking down sub-main wiring of any type complete all as specified and as directed.
Taking down DB of any size complete all as specified and as directed.
Material and Labour for point wiring in and including rigid non-metallic PVC conduit medium grade ISI marked of suitable dia on surface of wall/ceiling, with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper conductor of 1.5 Sqmm as continuous earth wire complete for one light point/ point controlled by one switch.
`-Ditto- all as per item No 39 above but one exhaust fan controlled by one switch
`-Ditto- all as per item No 39 above but one fan point by one switch and regulator
`-Ditto- all as per item No 39 above but one 5 Amps socket outlet point on same board along with other switch.
`-Ditto- all as per item No 39 above but one 5 Amps socket outlet point on independent board controlled by one switch.
Material and Labour for point wiring in and including rigid casing and capping, ISI marked of suitable dia, on surface of wall/ ceiling with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper conductor of 1.5 Sqmm as continuous earth wire complete for one light point/ point controlled by one switch.
`-Ditto- all as per item No 40 above but one exhaust fan controlled by one switch
`-Ditto- all as per item No 40 above but one fan point by one switch and regulator
`-Ditto- all as per item No 40 above but one 5 Amps socket outlet point on same board along with other switch.
`-Ditto- all as per item No 40 above but one 5 Amps socket outlet point on independent board controlled by one switch.
Material and Labour for point wiring non-metallic PVC conduit medium grade ISI marked of suitable dia on surface of walls/ceiling, with 2.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded copper conductor of 2.5 Sqmm as continuous earth wire complete all as specified and as directed.
Material and Labour for point wiring casing and capping, ISI marked of suitable dia on surface of wall/ceiling, with 2.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inside & outside for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover with brass screw , cup washer & including PVC insulated & unsheathed stranded copper conductor of 2.5 Sqmm as continuous earth wire complete all as specified and as directed.
Material and Labour for point wiring in existing PVC conduit medium grade/casing and capping of concealed/open, ISI marked of suitable dia, with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inside & outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper conductor of 1.5 Sqmm as continuous earth wire complete for one light point/ point controlled by one switch.
`-Ditto- all as per item No 43 above but one exhaust fan controlled by one switch
`-Ditto- all as per item No 43 above but one fan point by one switch and regulator
`-Ditto- all as per item No 43 above but one 5 Amps socket outlet point on same board along with other switch.
`-Ditto- all as per item No 43 above but one 5 Amps socket outlet point on independent board controlled by one switch.
Material and Labour for point wiring in existing PVC conduit medium grade/casing and capping of concealed/open, ISI marked of suitable dia, with 2.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes & 1.6mm thick duly painted inner & outside for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover with brass screw, cup washer & including PVC insulated & unsheathed stranded copper conductor of 2.5 Sqmm as continuous earth wire complete all as specified and as directed.
Material and Labour sub main wiring with 2 runs of 2.5 sqmm PVC insulated unsheathed 1100-volt grade multistranded copper conductor including PVC conduit and provision of one run 2.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and as directed. Note : 3 runs of 2.5 sqmm copper conductor, & one run of PVC conduit shall be measured as one unit length.
Material and Labour sub main wiring with 2 runs of 2.5 sqmm PVC insulated unsheathed 1100-volt grade multistranded copper conductor casing & capping of suitable size and provision of one run 2.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and as directed. Note : 3 runs of 2.5 sqmm copper conductor, & one run of PVC conduit shall be measured as one unit length.
Material and Labour sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed 1100-volt grade multistranded copper conductor including PVC conduit and provision of one run 4 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and as directed. Note : 3 runs of 4 sqmm copper conductor, & one run of PVC conduit shall be measured as one unit length.
Material and Labour sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed 1100-volt grade multistranded copper conductor casing & capping of suitable size and provision of one run 4 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and as directed. Note : 3 runs of 4 sqmm copper conductor, & one run of PVC conduit shall be measured as one unit length.
Material and Labour sub main wiring with 2 runs of 2.5 sqmm PVC insulated unsheathed 1100-volt grade multistranded copper conductor in existing PVC conduit /casing & capping of suitable size and provision of one run 2.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and as directed. Note : 3 runs of 2.5 sqmm copper conductor, & one run of PVC conduit shall be measured as one unit length.
Material and Labour sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed 1100-volt grade multistranded copper conductor in existing PVC conduit /casing & capping of suitable size and provision of one run 4 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified. Note : 3 runs of 4 sqmm copper conductor, & one run of PVC conduit shall be measured as one-unit length.
Supply and laying or fixing or passing through pipe or cable duct from meter room to the various floors of multi-storey building, up to 10th floor,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor with an inner sheathing of PVC tape armoured with galvanized steel or tape and over all PVC sheathed 16 sqmm 4core wire including taking up/down old cable complete all as specified and as directed.
Supply only electronic Fan regulator stepped type flush type suitable for existing ceiling fans fixed on phenolic laminated sheet etc. as reqd and as directed.
Notes: - (i)Wiring shall be carried out in multi storeyed building up to 12th floor and rate for transportation of materials and tools are deemed to be included in the quoted rate. (ii) The quoted rate shall deemed to be included for the cost of minor items like insulation tape, screws, etc. (iii) The materials required for replacement shall be measured and paid separately under respective item. (iv) Complaints lodged by Users shall be attended on all days including Sundays/holidays. (v) Minimum one electrician and one mate shall be detailed for one set of complaints, with all required tools in neat tool bag. (vi) The tradesmen shall wear uniforms with safety shoes including all necessary safety gear. (vii) Complaints/job cards shall be collected from complaint cell and trade man shall submit the feedback of complaints within two days, if fails to attend the complaint in prescribed time, penalty of Rs. 500 per complaint per day will be recovered for any non-attended /incomplete assigned complaints.
AB CONSTRUCTIONS (BID ID -3383950)
St George Engineering Works (BID ID -3390838)
HIGH TECH ENGINEERS AND CO (BID ID -3383794)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .