Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-Finance | L1 | Accepted-Finance Lowest Bid | |
| 2 | L2₹7.2 L+₹24,276 (3.47%)Rejected-Finance P O DHAP DHAPI MALLICKPUR P S BARUIPUR 24PGS S PIN 743387 | 24 PARAGANAS SOUTH | WEST BENGAL | 743387 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹8.0 L+₹1.0 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Higher Bid | |
| 4 | L4₹8.3 L+₹1.3 L (19.0%)Rejected-Finance 143 C DR RAJENDRA ROAD KOLKATA 700020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | L4 | Rejected-Finance Higher Bid | |
| 5 | L5₹8.8 L+₹1.8 L (25.9%)Rejected-Finance | L5 | Rejected-Finance Higher Bid |
| Sl No | Description | Qty | Unit | PUSPA ELECTRIC L2 | Sanjay Shaw L5 | BIKASH ENTERPRISE L4 | Ms G G TRADERS L1 | BHARAT INFOCOM L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V DP 32A with fuse on L&N. [Make-Havells / Standard / HPL] | 1 | Each | 1,050 ₹1,050 | 1,137 ₹1,137 | 1,375 ₹1,375 | 900 ₹900 | 250 ₹250 Lowest |
| 2.00 | S&F of 250V double door Compound Light Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DP Isolator ('C' curve 10KA), 1 no. 16A SPMCB ('C' curve 10kA), 1 no. Neutral Link, 1 no. Programmable Digital Astro time switch-24 hrs with minimum switching of 15 minutes and 1 no. 25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running/OFF condition with mechanical locking arrangement, as directed by EIC.
[Make-ABB/L&T/Crabtree] | 7 | Nos | 4,700 ₹32,900 | 7,565 ₹52,955 | 10,250 ₹71,750 | 3,200 ₹22,400 Lowest | 10,500 ₹73,500 |
| 3.00 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS.
40A DP (for SPN/DP incomer) [Make-Legrand/ABB/L&T/Siemens] | 5 | Item | 250 ₹1,250 Lowest | 411 ₹2,055 | 650 ₹3,250 | 700 ₹3,500 | 450 ₹2,250 |
| 4.00 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, on wall with iron frame arrangement & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.
2 way. | 5 | Each | 290 ₹1,450 Lowest | 712 ₹3,560 | 350 ₹1,750 | 350 ₹1,750 | 450 ₹2,250 |
| 5.00Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required(make-Polycab/Havells/Finolex/RR kabel) | ||||||||
| 5.01 | 2 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 60 | RM | 85 ₹5,100 | 89 ₹5,340 | 320 ₹19,200 | 20 ₹1,200 | 15 ₹900 Lowest |
| 6.00Supply of 1.1 KV grade 2/4 Core XLPE/PVC Insulated & Sheathed Armoured Aluminium Conductor cables of following sizes [Make : Havells / Gloster/Polycab] | ||||||||
| 6.01 | 2 Core 10 Sqmm | 1,300 | Mtr | 160 ₹2,08,000 | 160 ₹2,08,000 | 125 ₹1,62,500 | 60 ₹78,000 Lowest | 170 ₹2,21,000 |
| 7.00 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed | 300 | RM | 156 ₹46,800 | 220 ₹66,000 | 160 ₹48,000 | 35 ₹10,500 Lowest | 50 ₹15,000 |
| 8.00 | Laying only Cable upto 50 sqmm through existing RCC/ Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core | 50 | RM | 53 ₹2,650 | 40 ₹2,000 | 40 ₹2,000 | 35 ₹1,750 | 20 ₹1,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹19,049
Closing Date
18 Aug 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, South 24 Parganas Electrical Division
Office of the Executive Engineer, PWD South 24 Parganas Electrical Division 57/2 Diamond Harbour Road Kolkata 700 023
Compound lighting arrangement at Diamond Harbour Court complex in the district of South 24 Parganas.
2025_WBPWD_886915_1
WBPWD/EE/S24PED/eNIT30/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
DIAMOND HARBOUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹19,049
South 24 Parganas Electrical Division
16 Sept 2025
4 Aug 2025
20 Aug 2025
4 Aug 2025
18 Aug 2025
12 Aug 2025
11 Aug 2025
Amount
Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V DP 32A with fuse on L&N. [Make-Havells / Standard / HPL]
S&F of 250V double door Compound Light Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DP Isolator ('C' curve 10KA), 1 no. 16A SPMCB ('C' curve 10kA), 1 no. Neutral Link, 1 no. Programmable Digital Astro time switch-24 hrs with minimum switching of 15 minutes and 1 no. 25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running/OFF condition with mechanical locking arrangement, as directed by EIC. [Make-ABB/L&T/Crabtree]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS. 40A DP (for SPN/DP incomer) [Make-Legrand/ABB/L&T/Siemens]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, on wall with iron frame arrangement & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 way.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required(make-Polycab/Havells/Finolex/RR kabel)
2 x 36/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply of 1.1 KV grade 2/4 Core XLPE/PVC Insulated & Sheathed Armoured Aluminium Conductor cables of following sizes [Make : Havells / Gloster/Polycab]
2 Core 10 Sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying only Cable upto 50 sqmm through existing RCC/ Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S&F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required 32 mm dia ISI-M
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/ PVC armoured cables as below as to G S.
2 Core 10 Sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. S&F solderless socket etc as per GS.
2 Core 10 Sqmm
Supply and delivery of LED Street fitting 90 Watt 10800 lumen(Minimum), (230V AC, 50Hz, 3000K IP66, THD<10%, built in 2.5KV SPD) with all accessories [Make-Philips, Crompton, Havelles, Bajaj, or as per EIC]
Supply and delivery of LED Street fitting 70 Watt, 8400 Lumen (Minimum ( 230V AC, 50Hz, 3000K IP66, THD<10%, built in 2.5KV SPD) with all accessories [Make-Philips, Crompton, Havelles, Bajaj, Surya or as per EIC]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
S/F 80 mm dia 1.5Mt long mini GI pole [TATA-M] including painting and S/F 1no 10mm thick GI flange as base plate including necessary holes as required including providing cement concrete(6:3:1) muffing around pole of dimension 450mm X 450mm X 600mm above roof level on the pole with cement mortar plastering and neat cement finish. Including S/F 200mmX150mmX100mm GI loop box with 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable & 25mm dia alkathane pipe for cable entry as per direction of EIC. (86-65 micron dry film thickness) (As per IS 5986: IS 4759/2629, ASTM A123 and BSEN IS 1461 standard.) (Incl S & F of item no 16.01) ( Make - Bansal/ Utkarsh/ subham/Jindal/TATA-M) as per GS
S&f 50 mm 1.5 mtr long detachable type G.I single arm bracket, suitable for polehead . The arm bracket shall be properly weded with 15 mm . Stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the poleby bolts, nuts andwasher as per directionof EIC ( Make - Bansal/ Utkarsh/ subham/Jindal) as per GS
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anti-corrosive paint.
Supply & delivery of swaged type MS tubular pole conforming to IS:2713/1980 (7 mtr long, 410-SP-3) as per direction of EIC.(Bansal/utkarsh/Subham/Jindal)
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x 600x 150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole
(i) One coat of red lead/Zinc chromate priming
(ii) 1st coat of synthetic enamel paint over the primer
(iii) 2nd coat of synthetic enamel paint over the 1st coat
S&f 50 mm 1.5 mtr long detachable type G.I single arm bracket, suitable for polehead . The arm bracket shall be properly weded with 15 mm . Stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the poleby bolts, nuts andwasher as per directionof EIC ( Make - Bansal/ Utkarsh/ subham/Jindal) as per GS
S&F of Double arm header fabricated with 100 mm dia, 3 mm thick & 10" height G.I. pipe (pole cap) welded with 2 nos. 1.5 mtr. long 40 mm dia. 3 mm thick G.I. pipe at an angle of 20 to 25 deg with horizontal axis and 180 deg. angle between two arms by using nuts, bolts washers etc. incl. painting by 2 coat Aluminium paint over 1 coat RO Primer after cleaning the surface by emery paper as per direction of E.I.C..
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run [Arrangement of Scafholding for fixing Outdoor Unit of AC Machine.]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe.
Connecting the equipments to earth busbar including S&F GI (Hot Dip) wire of size 8 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Miscellance
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning.
PUSPA ELECTRIC (BID ID -6849138)
BHARAT INFOCOM (BID ID -6836266)
BIKASH ENTERPRISE (BID ID -6834100)
Sanjay Shaw (BID ID -6850134)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .