| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 37 B SAHEB KRUPA SOC JIVAN CHETAN SCHOOL SAMA ROAD VADODARA GUJARAT PIN 390 008 | VADODARA | GUJARAT | 390008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.2 L+₹25,145 (5.07%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹6.1 L+₹1.2 L (23.9%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹9,680
Closing Date
13 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2024_MES_654018_1
8797
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BARODA
As per tender documents
5 documents required · 5 mandatory
₹300
Yes
GE ARMY BARODA
₹9,680
Yes
2 Sept 2024
15 May 2024
18 Jun 2024
15 May 2024
13 Jun 2024
31 May 2024
15 May 2024 - 30 May 2024
Amount
Taking down cement plaster on brick/concrete surface including raking out joints hacking for key scrubbing down with water etc.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each
Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sq m but n.exc 4.00 Sq m each
S&F of Powder coated aluminium frame (minimum thickness of powder coating 50 micron)for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
S&F 4.00mm thick sheet glass, ordinary quality and glazing with rubber beading or with glazing clips exc 0.5 sq. m in each pane including solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework (caging) of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed
M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6, finished even and smooth (without using extra cement)
M & L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed.
M & L for 40 mm thick cement concrete in flooring type B0, 1:2:4 (12.5mm graded aggregate) for laying floor finished even and smooth using extra cement.
M & L for 3 mm thick EPU floor coating system including surface preparation by clearing from dust, muck,moisture & all foreign material and cleaned by mechanical scrubber/ grinder, chemical treatment for oil if required followed by application of primer Cipoxy 11 which shall be a two component, solvent free, epoxy polyamido amine system having a volumetric ratio of mixing of 1: 1 to yield a thickness of 100 microns then providing and applying the screed layer with Cipoxy 18 of minimum thickness of 2000 microns. The self levelling screed shall consist of a low viscous epoxy-amine cured system and graded aggregates (Special Silica). The epoxy system shall have a volumetric ratio of mixing of resin in 1: 1 ratio. The aggregates shall be added in the ratio of 1: 3.5 to 4 over that Epoxy Polyurethane (EPU) top coat of Cipy Cipothane SL which is a pre-weighed pack ready to mix and use which will consists of resin, hardner, EPI (Colour concentrate) formulated aggregates. All these 4 parts to be added to agitate the mixture by an electrically driven motor and lay the mixture to the thickness of 1000 microns and demarcation with PU material i.e. FK 666 which will be 2 component 1:1 ratio on top coat complete all as specified and directed,including M & L for construction/ Dummy/ Expansion joint filling including joint treatment by surface preparation by clearing from dust, muck moisture & all foreign material, application of primer of Duraprime 100, installation of back-up rod and filling of PU based coloured sealant complete all as specified and directed.
Taking down carefully existing unserviceable copper/aluminium point wiring (light, fan, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, etc (except tube light fittings), and making good disturbed surface of wall, floors, etc complete all as directed by Eng-in-Charge.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC Conduit and all accessories Concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following:-
One light point controlled by one switch.
One ceiling fan point controlled by one switch
One 3 pin socket outlet 5 Amps independent board.
One 3 pin socket outlet 5 Amps on the same board with other switch.
All as per item No.14 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket.
S & F switch piano flush type SP one way 6 Amp.
S & F switch socket combination 2 in 1, 3 pin, 6 and 16 amp flush type universal.
S & F switch socket combination 2 in in 1, 5 A flush type.
S & F Socket outlet 2 in 1 , 3 pin, 6 Amps flush type.
S & F ceiling rose surface polycarbonate body three terminal.
S & F stepped type electronic fan regulator flush type on the laminated sheet complete.
S & F of ceiling fan complete with blades, down rod from existing roof / trus to fall ceiling and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, star rated with motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed. Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard
Supply and fix of LED light fitting 1X20Watt, 220 Volt AC decorative box type with drivers, holders and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable existing light fitting complete all as specified and directed.
Sub main wiring with FRLS four run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 10.0 Sqmm size drawn through and including not less than 32 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 10.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. Note : Four runs of single core 10.0 sqmm and one run of 10.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Sub main wiring with FRLS four run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 32 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. Note : Four runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Sub main wiring with FRLS two run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 32 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. Note : two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
Supply and fix CRCA sheet metal enclosures distribution board double door,TPN vertical DB 4 way suitable for fixing of Four pole MCCB as in commer & MCBs SP as out going and duly fitted with Bus bar, neutral link, blanking plates, conforms IS 8623-1 & 3, IEC 61439-1 & 3, IK 09 etc complete.The DB shall be included with one No MCCB, 4 pole, 415/430 Volt, 50 Hz, Ics=100% of Icu, having rupturing capacity 16 kA on 415 V icu of capacity 125 Amps complete all as specified and directed. Encloser & MCCB shall preferably of same make. ( MCB s required for out going shall be measured and paid seperately) Make :- Legrand / Schiender / Siemens / Havells
S & F MCCBs in VTPN DB of capaxity 100 Amp 415 V, 16 KA, 4 Pole complete all as specifed and directed
S & F MCB DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rated bus bar 240/430V complete all as directed by Engr-incharge.
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 12 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed
S & F MCB Single pole (SP), having rupturing 10KA, 6 Amp to 32 Amp as ordered.
S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered.
S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240 V 32 amps as ordered.
S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240 V 63 amps as ordered.
S & F MCB Triple pole (TP), having rupturing 10KA, 240 V 63 amps as ordered.
S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete complete all as specified and directed
Taking down existing earthing and M & L Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including necessary earth work and excavation all as specified or indicated including testing on completion
P K SHETH
Badri Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .