| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.6 LAccepted-AOC | 1 | Accepted-AOC first lowest | |
| 2 | 2₹6.0 L+₹42,476.60 (7.59%)Rejected-AOC | 2 | Rejected-AOC second lowest | |
| 3 | 3₹6.5 L+₹91,801.24 (16.4%)Rejected-AOC | 3 | Rejected-AOC third lowest |
Tender Value
₹7.7 L
EMD Value
₹19,277
Closing Date
19 Oct 2023, 2:30 pmClosed
Assistant Executive Engineer
Water Supply Sub Division, Kanjiramkulam
DEPOSIT Tvm corporation Janakeeyasoothranam No S00548 20 Line extension at Venganoor ward near Girls HSS to Mudippura LPS and Neelakeshi auditorium to Chavadinada road under Kanjiramkulam section
2023_KWA_611134_1
10/2023-24/KJM
Open Tender
Civil Works - Water Works
Item Rate
180 days
Kanjiramkulam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,700
₹19,277
Yes
21 Dec 2023
11 Oct 2023
21 Oct 2023
11 Oct 2023
19 Oct 2023
11 Oct 2023
Amount
Labour Charges
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD51936/2023-2024:Taking connection from the existing main /Double boring /supplying and fitting 25 mm saddle piece, boring the main supplying and fitting 25 mm brass ferrule 2no,25 mm GM full way valve 2no,bend2 nos, union 2no, 32mm pvc adapter 2no , 90x32 reducer 2 no etc and connecting the line,testing,jointing etc complete
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
100.98.1008:Engaging Coolie.
Construction of Valve Chamber
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD51872/2023-2024::Conveying CI MH cover with frame from depatmental store to site
Supply of materials
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
OD51642/2023-2024:Supplying solvent cement
OD51817/2023-2024::Supplying,conveying and fixing 80 mm GM valve
OD51830/2023-2024::Supplying 90 mm PVC Bend
OD51833/2023-2024::Supplying 90 mm PVC End cap
PRADEEP KUMAR K R
SUDHARMAN V
Bidder Name
SUDHARMAN V
Renjith M
PRADEEP KUMAR K R
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_913286.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .