Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Vendor | |
| 2 | L2₹18.4 L+₹32,140 (1.78%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹20.8 L+₹2.7 L (15.2%)Rejected-Finance DOOR NO 14 6 21 5 OPP MARVAL SCHOOL BC ROAD NEW GAJUWAKA VISAKHAPATNAM 530026 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530026 | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹24.1 L+₹6.1 L (33.7%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L4 | Rejected-Finance Being Not L1 | |
| 5 | Rejected-Technical 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | - | Rejected-Technical Not recommended since not enlisted with appropriate category |
| Sl No | Description | Qty | Unit | bhavani constructions L1 | REAL ENGINEERING WORKS L3 | SRI SIDDHI VINAYAKA ENTERPRISES L2 | ANAND ENTERPRISES AND ENGINEERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix acryllic LED name board as designed with radium glow lettering along with frame, base and structure support and internally wired for lighting waterproof for fixing at outdoor including plug in the remote receiver and power adaptor and as per site complete all as specified and directed.
Note :- The letters/design to be displayed will be approved by Engineer-in-Charge and prior approval to be taken. | 6 | Each | 20,000 ₹1,20,000 | 8,000 ₹48,000 Lowest | 11,000 ₹66,000 | 9,500 ₹57,000 |
| 2.00 | Supply and fix distribution diagrams of AC plant along with frame, base and structure support and as per site complete all as specified and directed.
Note :- The letters/design to be displayed will be approved by Engineer-in-Charge and prior approval to be taken. | 4 | Each | 20,000 ₹80,000 | 8,000 ₹32,000 Lowest | 9,200 ₹36,800 | 9,300 ₹37,200 |
| 3.00 | Preventive maintenance of central type AC plant by carrying out routine check of the Plant complete for smooth functioning all as per manufacturer's instructions and as directed for 39.0Tr *03 Nos. installed at SMU bldg including attending to under mentioned jobs to ensure its satisfactory performance:-
Note: Quoted Rates are deemed to be for carrying out checks as under.
(a)Contractor has to deploy manpower at the worksite to attend the breakdown calls received from representatives during two shifts throughout the week including sundays & holidays and on emergencies in third shift shall be attended ,preventive maintenance for the entire duration of contract.It is the contractors responsibility to make the unit functional and sufficient stock of spares shall be maintained to rectify the breakdown within scheduled period. | 11 | Per Month | 5,000 ₹55,000 Lowest | 11,500 ₹1,26,500 | 10,000 ₹1,10,000 | 8,500 ₹93,500 |
| 3.01Cleaning, stacking, sorting, handling and upkeeping of maintenance shall be carried out by contractor. (b)checking the system for visual leaks at all flare fittings and arresting (c)carrying out leak test with soap solution in case reports indicate frequent loss/recharging of refrigerant into the system whenever required (d)checking operation ,suction& discharge pressures.In case of any abnormality identifying and correcting the same (e)checking and setting of safety controls such as HP/LP cutouts,overload protections and thermostats etc. (f)cleaning of pre air filters and replacing the same if necessary (g)checking lubricating oil level at the sight glass if found below the normal level the problem shall be analyzed and rectified. | |||||||
| 3.02(h)Running of standby unit and observe for satisfactory performance. (i)checking the incoming voltage and running currents and take appropriate measures (j)checking for any abnormal noise/vibration from moving parts such as compressors,motors,fans etc in case of any abnormality,investigating and correcting the same (k)checking and rectifying any water leaks and arresting them (l)checking the operation of controls and making them functional (m)checking and cleaning of fan,runner blades and replace if required (n)cleaning cooling coils by cleaning agent (CFC free) (o)checking the cooling tower water level (p)checking the water level in the makeup water tank | |||||||
| 3.03(q)starting and checking the running condition of cooling tower fan (r)starting the pump and checking the running condition including checking the NRVs (s)cleaning condensate drain tray (t)checking the cooling tower nozzles for proper spray and replacing the same if necessary u)Descaling the condenser and replacing the condenser end shield gaskets Record of these shall be maintained and submitted monthly to engineer in charge The above quoted rate is inclusive of all spare parts apart from below mentioned spare parts which will be paid seperately to make the unit completely functional, T&P manpower required in the site | |||||||
| 4.00 | All as per item No. 3.00 above, but for 39 Tr x 3 Nos. at MI room | 11 | Per Month | 5,000 ₹55,000 Lowest | 11,500 ₹1,26,500 | 10,000 ₹1,10,000 | 8,500 ₹93,500 |
| 5.00 | All as per item No. 3.00 above, but for 39 Tr x 3 Nos. at Auditorium room | 11 | Per Month | 5,000 ₹55,000 Lowest | 11,500 ₹1,26,500 | 9,000 ₹99,000 | 8,500 ₹93,500 |
| 6.00 | All as per item No. 3.00 above, but for 50 Tr x 3 Nos. at Electrical dept | 11 | Per Month | 10,000 ₹1,10,000 Lowest | 16,000 ₹1,76,000 | 10,200 ₹1,12,200 | 11,500 ₹1,26,500 |
| 7.00 | All as per item No. 3.00 above, but for 50 Tr x 2 Nos. at Periscope bay | 11 | Per Month | 10,000 ₹1,10,000 Lowest | 16,000 ₹1,76,000 | 10,200 ₹1,12,200 | 11,500 ₹1,26,500 |
Tender Value
₹35.0 L
EMD Value
₹69,980
Closing Date
29 Apr 2026, 6:30 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
PERIODICAL MAINTENANCE/IMPROVEMENT OF AC PLANTS AND REPLACEMENT OF SAFETY RELATED WORKS INCLUDING SAFETY DISPLAY BOARDS DISTRIBUTION DIAGRAMS AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2026_MES_759369_1
8513/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹69,980
Yes
18 Jul 2026
8 Apr 2026
1 May 2026
8 Apr 2026
29 Apr 2026
22 Apr 2026
9 Apr 2026 - 20 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supply and fix acryllic LED name board as designed with radium glow lettering along with frame, base and structure support and internally wired for lighting waterproof for fixing at outdoor including plug in the remote receiver and power adaptor and as per site complete all as specified and directed.
Note :- The letters/design to be displayed will be approved by Engineer-in-Charge and prior approval to be taken. | - | Each | - | - |
| - | Supply and fix distribution diagrams of AC plant along with frame, base and structure support and as per site complete all as specified and directed.
Note :- The letters/design to be displayed will be approved by Engineer-in-Charge and prior approval to be taken. | - | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_850563.xls
BOQ • 0.31 MB
8513Tender.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .