Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.8 L+₹1.8 L (15.5%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹17.9 L+₹6.0 L (50.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹19.0 L+₹7.1 L (59.2%)Rejected-Finance 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹24.8 L+₹12.9 L (108.6%)Rejected-Finance 216 BHARAT NAGAR INDRAPURI BHOPAL MADHYA PRADESH 462021 | BHOPAL | MADHYA PRADESH | 462021 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
20 Sept 2021, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-27/2021-22 REPAIRS / MAINTENANCE OF FIRE ALARM / DETECTION SYSTEM IN OTM ACCOMMODATIONS AT AF STATION AMBALA
2021_MES_459058_2
GE AF/AMB-27/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DODCUMENTS
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹40,000
Yes
23 Nov 2021
28 Aug 2021
22 Sept 2021
28 Aug 2021
20 Sept 2021
7 Sept 2021
Amount
M&L for checking serviceability of addressable type fire alarm system with control panel, wiring and detectors of any type and locating fault therein and repairing and rectifying the fault by replacing faulty parts / accessories and reconnecting the entire system and testing on completion complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Defective parts replaced will be measured and paid separately under respective item (iii) System diagram in AutoCAD, of the entire system duly marked with detectors, hooters, fire extinguishers, etc. in A3 size shall be submitted in quadruplicate to the Engineer-in-charge (iv) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor. Test certificates shall be duly vetted by all concerned and shall be submitted alongwith RAR (v) One display chart duly framed (of size as directed) showing the complete system diagram of each building in AutoCAD shall be fixed on each floor. Cost of same shall be included in the quoted rate
M&L for checking serviceability of conventional type fire alarm system with control panel, wiring and detectors of any type and locating fault therein and repairing and rectifying the fault by replacing faulty parts / accessories and reconnecting the entire system and testing on completion complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Defective parts replaced will be measured and paid separately under respective item (iii) System diagram in AutoCAD, of the entire system duly marked with detectors, hooters, fire extinguishers, etc. in A3 size shall be submitted in quadruplicate to the Engineer-in-charge (iv) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor. Test certificates shall be duly vetted by all concerned and shall be submitted alongwith RAR (v) One display chart duly framed (of size as directed) showing the complete system diagram of each building in AutoCAD shall be fixed on each floor. Cost of same shall be included in the quoted rate.
M&L for checking serviceability state of control panel of addressable type fire alarm any tupe, detecting the faults and rectifying by replacing defective / unserviceable items/parts through competent technician / Engineer of the manufacturer and testing for functionality, etc. complete all as specified and as directed Notes: (i) Job shall be done under supervision of qualified technician / Engineer of OEM / manufacturer (ii) Cost of all defective parts / spares, etc. whatsoever replaced to make the system functional to the entire satisfaction of the Engineer-in-charge shall be included in the quoted rate (iii) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor
S&F in repairs control panel of conventional type fire alarm system and reconnecting the entire system and testing on completion complete all as specified and as directed Notes: (i) Job shall be done under supervision of qualified technician / Engineer of OEM (ii) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor
Supplying, installing, testing and commissioning of analog addressable fire alarm control panel (FACP) 1 loop (NFS3030D) expandable upto 10 loops, with battery charger and battery back up for 8hrs, normal operation and 1hr alarm operation, with full featured operator interface control and annunciation panel including backlit 640 characters LCD, QWERTY style alphanumeric keypad for field programming and control of fire alarm system supporting upto 99 detectors and 99 modules in one loop including requisite licensed system software and hardware complete all as specified and as directed Notes: (i) The panel shall be UL listed, FM approved and complying to UL-864, 9th edition (ii) The enclosure shall be UL listed (iii) The requisite software and hardware for panel programming shall be as approved. The same shall be licensed version, activated for a minimum period of 3yrs from date of installation (iv) The quoted rate shall include all the above
Supplying, installing, testing and commissioning of analog addressable multi sensor smoke cum heat detector with hard addressing feature, with visible bi-colour LEDs for 360o viewing, duly fixed with standard base and junction boxes where required on false ceiling / soffits, etc. including taking down old sensors from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of analog conventional multi sensor smoke cum heat detector with hard addressing feature, with visible bi-colour LEDs for 360o viewing, duly fixed with standard base and junction boxes where required on false ceiling / soffits, etc. including taking down old sensors from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of addressable manual call point including taking down old call points from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of control module for manual call point including taking down old modules from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of hooter / strobe rated at 82dBA @3m for audible annunciation and 75cd flashings at 1Hz with visual indication for addressable type fire system including taking down old hooters from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of response indicator for fire system including taking down old indicators from any location / position and disposing off complete all as specified and as directed
Supplying, installing, testing and commissioning of hooter / strobe rated at 82dBA @3m for audible annunciation and 75cd flashings at 1Hz with visual indication for conventional type fire system including taking down old hooters from any location / position and disposing off complete all as specified and as directed
S&F in repairs 2 core 1.5sqmm PVC insulated FRLS armoured copper cable, dark red (in SRC loop and power supply) conforming to relevant IS complete all as specified and as directed
S&F in position dry type battery 12V, 7Ah/20hrs (CE ISO-9001) including taking down and disposing off old battery complete all as specified and as directed
S&F in repairs battery charger 240V 50Hz for charging batteries upto 12V 6Ah to 180Ah with trickle / boost charging mode complete all as specified and as directed
S&F in repairs DOL starter 3 phase 440V suitable for 3/5/7.5HP motors complete all as specified and as directed
M&L for checking serviceability of sprinkler pump, diesel engine, hydrant pump, jockey pump, etc. in 440V 3 phase 50Hz system of existing fire fighting of any type with 30m head, 2280LPM discharge and locating fault therein and repairing and rectifying the fault by replacing faulty parts / accessories and reconnecting the entire system and testing on completion complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Cost of defective parts replaced shall be included in the quoted rate (iii) Testing shall be done in presence of the Users, Engineer-in-charge, Contractor and rep of the GE
S&F wall mounting swinging type first aid fire hose reel with drum, conforming to IS-444 including hanging bracket, 20mm dia pressure hose reel (conforming to IS-884-1985) 30m long, gunmetal nozzle 5mm dia of orifice and 25mm dia MS pipe complete all as specified and as directed Notes: (i) Cost of 25mm dia MS pipe of requiste length for connecting to valve shall be included in the quoted rate (ii) Drum shall be fixed on adjoining wall with anchor fasteners and duly grouted
M&L for checking serviceability of star delta control panel and locating fault therein and repairing and rectifying the fault by replacing faulty parts / accessories and reconnecting the entire panel and testing on completion complete all as specified and as directed Notes: (i) Job shall be done by qualified technician / Engineer of OEM (ii) Cost of defective parts replaced shall be included in the quoted rate (iii) Testing shall be done in presence of the Users, Engineer-in-charge and the Contractor (iv) System diagram in AutoCAD, of the entire system duly marked with detectors, hooters, fire extinguishers, pump, etc. in A3 size shall be submitted in quadruplicate to the Engineer-in-charge (v) One display chart duly framed (of size as directed) showing the complete system diagram of each building in AutoCAD shall be fixed on each floor. Cost of same shall be included in the quoted rate
S&F in position 63mm dia 15m long controlled percolating rubberised fabric hose conforming to IS-8423 (type-A) including gun metal male and female sockets / nozzles complete all as specified and as directed
S&F pressure gauges with controlling cocks of bourdon material 100mm dia (minimum) including isolation valves on discharge pipe as per existing type and size complete all as specified and as directed
S&F pressure switch as per existing type and size complete all as specified and as directed
S&F in position cast iron wafer type butterfly valves, PN-1.6 pressure as per IS-210 GR FG 200 with flanges on both sides and operating lever complete all as specified and as directed of the following diameters:
80mm dia
100mm dia
150mm dia
S&F CO2 gas type portable fire extinguishers of capacity 4.5litres conforming to IS-15683-2006, ISI marked, consisting of seamless MS cylindrical body, squeeze lever discharge valve, internal discharge tube, 300mm high pressure discharge hose, discharge nozzle duly placed on walls, etc. with and including dash fasteners, brackets, etc. as required complete all as specified and as directed
S&F mechanical foam type fire extinguishers of capacity 9.0litres conforming to IS-15683-2006, ISI marked, consisting of seamless MS cylindrical body, trolley mounted, squeeze lever discharge valve, internal discharge tube, high pressure discharge hose/mouth, discharge nozzle duly placed on walls, etc. with and including dash fasteners, brackets, etc. as required complete all as specified and as directed
S&F dry chemical powder type (mono ammonium phosphate) fire extinguishers of capacity 4.5litres conforming to IS-15683-2006, ISI marked, consisting of seamless MS cylindrical body, trolley mounted, squeeze lever discharge valve, internal discharge tube, high pressure discharge hose/mouth, discharge nozzle duly placed on walls, etc. with and including dash fasteners, brackets, etc. as required complete all as specified and as directed
Supplying, fixing, testing and commissioning wall mounting swinging type first aid fire hose reel with drum, hanging bracket, with 30m long 20mm bore high pressure hose reel (as per IS:884-1985 updated upto date), gunmetal shut off nozzle, having 5mm dia orifice conforming to IS-444 (updated upto date) complete all as specified and as directed Note: Rate quoted shall be inclusive of the following: (i) 25mm bore MS pipe connection from valve of required length (ii) Drum shall be fixed on adjoining wall with anchor fastener / PCC block / MS stands (as required at site)
Esha Engineers
Continental Engineers and contractors
ALPHA ENGINEERS AND BUILDERS
FIRE PROTECTION SYSTEM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .