Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹15.3 L+₹11,405 (0.75%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹18.6 L+₹3.4 L (22.6%)Rejected-AOC BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC ok | |
| 4 | Rejected-Technical WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | - | Rejected-Technical NO in WLR in QE Mar 2021 of HQ CEBZ |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
27 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
PETTY REPAIRS TO INTERNAL ELECTRIC SYSTEM AT NEW AND OLD MH, PERSONNEL LINE MH AND CONNECTED SINGLE ACCN OF MH BAREILLY CANTT UNDER GE(WEST) BAREILLY
2021_MES_455037_1
8961/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORY SCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRMSCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹50,000
Yes
24 Aug 2021
26 Jun 2021
2 Aug 2021
26 Jun 2021
27 Jul 2021
12 Jul 2021
26 Jun 2021 - 10 Jul 2021
60 days
Amount
Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed.
M&L for concealed point wiring for one light/ fan/ bell point controlled by one switch with 1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable FRLS (1100Volts grade) drawn in and including PVC conduits of 20 mm dia with all fittings and accessories alongwith PVC insulated cable with copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with screws,cap and washers incl. making good the disturbed surfaces complete.
All as per item no.2 here in before but for socket outlet 3/5 pin 5 amp. on the same board.
All as per per item No 02 here-in-before but for one light point controlled by two Nos of 2 way switches complete all as specified and directed.
All as per item No 02 here-in-before but for 5 Amps 3/5 Pin point on independent board
M&L for concealed point wiring using approved colour coding as per IS (Red , black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI marked with valid CML No. including PVC conduit with mild steel/pressed steel sunken box (with earth dolly) with modular white cover plate with frame for mounting modular switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed by Engr-in-charge for the following :-
(a) One light/fan point controlled by one switch 5/6 Amp one way
(b) -Ditto- all as per item no.6 but socket outlet 3 pin 5/6 amps same board
(c) -Ditto- all as sper item No. 6 above but for one socket outlet of 5/6 Amps on independent board .
M&L for concealed point wiring with 2.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with solid copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20mm sunk pressed steel terminal box suitably flushed to wall with 3mm thick Hylum sheet cover fixed with screws & cup washers incl. making good complete.
M&L for concealed point wiring using approved colour coding as per IS (Red , black and Green for single phase circuits),with multistranded copper conductor 2.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI marked with valid CML No. including PVC conduit with mild steel/pressed steel sunken box (with earth dolly) with modular white cover plate with frame for mounting modular switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed by Engr-in-charge.
Supply and Fixing in repairs P/switch flush type 5/6 Amp SP one way.
Supply and Fixing in repairs P/switch flush type 5/6 Amp SP two way.
Supply and Fixing in repairs P/switch flush type 15/16 Amp SP one way.
Supply and Fixing in repairs ceiling rose 2/3 terminals
Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite.
Supply and Fixing in repairs Switch socket combination 5 amp flush type
Supply and Fixing in repairs Switch socket combination 2 in one 5 and 15 Amp flush type
Supply and Fixing in repairs buzzer, capton ding dong, AC, 230V, sigle pole.
Supply and fixing bell push switch flush type .
Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type
Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type
Supply and Fixing in repairs Modular switches 1 way, 6 A, 1 module
Supply and Fixing in repairs Modular switches 1 way, 16 A, 1 module
Supply and Fixing in repairs Modular sockets 6 A,-2/3 pin combined 2 module
Supply and Fixing in repairs Modular sockets 6 A/ 16 A,-2/3 pin combined 2 module
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' X 11'' including cutting of sheet for fixing switch / socket.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' x 5'' including cutting of sheet for fixing switch / socket.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 5'' x 5'' including cutting of sheet for fixing switch / socket.
Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA
Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA.
Supply and Fixing in repairs MCB TPN 63 Amps,415V,10kA
S &F in repair MCCB 16 kA,125Amp thermal magnetic and electronic earth leakage module complete all as specified and directed.
Taking down unserviceable existing sub main wiring with aluminium conductor stranded cable upto 6 Sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed. .
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 2.5 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 12 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways complete all as specified and directed.
Supply and Fixing in repairs 4 Pin CFL lamp 36Watt complete all as specified and directed.
S & F in repairs 2 Pin CFL 18 W lamp/LED bulb thread type complete all as specified and directed.
S&F in replacement LED fitting with PVC extruded battern 20watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
S & F retrofit LED tube rod 18/20 W, 4 feet for fixing in existing LED/FTL light fitting complete all as specified and directed.
S & F Side holder suitable for existing LED/FTL fittings as per site requirement complete all as specified and directed.
Supply and Fixing in repairs LED bulk head light fittings with all accessories with lamp, cover plate, 9W bulb, metal box etc complete as required as per standard make complete all as specified and directed.
S&F in repairs building security light led type 25 W complete all as specified and directed.
S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in repairs 4mm thick E-board tiles for insulation and acoustic purpose including aluminium snap grid with 25x25x1.5 mm thick tee section and 38x52x2 mm thick angle with hanging/suppoting arrangements as in false ceiling at bottom at spacing 60cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fasteners cmplete and making good disturbed surfaces including taking down old ceiling any type complete all as specified and directed.
S&F Surface mounted square shaped LED downlighter with durable housing with with diffuser with removable driver upto 12 watt complete all as specified and directed by Engr-in-charge.
S&F in replacement of PVC non metallic casing caping of 25 mm size with accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbed surface complete all as specified and directed
S&F LED mirror light fixture 9W LED 6000K complete all as specified and directed.
Supply and Fixing in repairs in replacement PVC insulated Flexible twin core,copper cable multistranded 24/.0020sqmm, 1100 V grade.
Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
M & L Re-winding of burnt fan motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size, make (ATLAS) or equivalent and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed.
Re-winding of exhaust fan motor of 450/300 mm sweep with appropriate size of super enameled copper wire, including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as directed.
Supply and Fixing in repairs Modular fan regulators step type, 120 W, 2 module
Supply and Fixing in repairs fan regulator resistance/electronic step piano type single phase 230 volt.
Supply and Fixing in repairs Condenser 2.5 Mfd make universal/Usha /Bajaj/Epcos.
Supply and Fixing in repairs Condenser 3.5 Mfd make universal/Usha /Bajaj/Epcos.
Supply and Fixing in repairs bush of fans of any size complete all as directed.
Supply and Fixing in repairs insulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
Supply and Fixing in repairs shaft of fans (as per sample) of suitable size complete all as specified and directed
Supply and Fixing in repairs of fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed.
Supply and Fixing in repairs fan down rod made out of 15 mm dia medium grade GI pipe, Med grade including threading on both end of pipe, drilling holes etc. as required including primer complete all as specified and directed.
Supply and Fixing in repairs fan conopy, suitable for various type ceiling fan all as per sample and directed.
M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge.
Taking down of unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directed by Engr in Charge.
S&F in repairs heating element 2.0 KW as triangular type/ circular type as per sample all as directed by the Engr in Charge.
S&F only new inner shell of geyser capacity 25/35 liters of suitable size made of copper sheet of 22 SWG complete with all suitable accessories complete all as specified and directed.
M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity/size complete all as specified and directed.
Supply only new safety pressure valve with vent to geysers as per latest ISI specification and directed.
M&L for Painting the outer surface of geyser capacity 25/35 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed.
M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed.
S&F assemblly of geyser 25/35/50 ltr.capacity as specified and directed by Engg. In charge.
Supply and Fixing in repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230Volt
Supply and Fixing in repairs PVC connection flexible heavy grade 45 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed.
Supply and Fixing in repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser
Supply and Fixing in repairs Plug top 15 Amps Make Anchor or equivalent complete all as specified.
Dismantling,inspection,repairing and re assembling after making emergency light fitting completely function including testing after repair and replacement of unsv parts complete all as specified and directed. NOTE:- The cost of battery and transformer will paid separately under item No 80 and 81 and light bulb and the cost of other spares deemed to be included in the quoted rate.
S & F in repair emergency light battery 12 volts 26 AH complete all as specified and directed.
S &F in repair transformer for emergency light charging of battery 12 volts 26 AH complete all as specified and directed.
Dismantling,inspection,repairing and re assembling after making shadowless light fitting completely function including testing after repair and replacement of unsv parts complete all as specified and directed. NOTE:- The cost of OT bulb will be paid under item No 83 and the cost of other spares deemed to be included in the quoted rate.
Supply only bulb 12 volt 50 watt suitable for OT shadow less light fitting Make philips/Havells/Surya or equivalent.
Dis assembling ,inspection,cleaning and servicing of 1.0 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors, trransformer, batteries etc complete all as specified and directed.NOTE:- The cost of batteries will be paid under item No 87 . The cost of other spares deemed to be included in the quoted rate.
Dis assembling ,inspection,cleaning and servicing of 2.5 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors,transformer, batteries etc complete all as specified and directed.NOTE:- The cost of batteries will be paid under item No 87 . The cost of other spares deemed to be included in the quoted rate.
Dis assembling ,inspection,cleaning and servicing of 5 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors, transformer, batteries etc complete all as specified and directed.NOTE:- The cost of batteries will be paid under item No 87 . The cost of other spares deemed to be included in the quoted rate.
Supply only UPS batteries 12 V 150 AH Make Exide/Amron/or equivalent complete all as specified and directed.
Supply olny rechargable LED lamp 12 watt, 230 V, AC integrated circuit complete all as specified and directed.
Supply and fixing adjustable surface mounted LED spot wall light with stand of 6 watt to 9 watt of make Surya/Havells/C&S or equivalent.
Supply and fixing name plate light smart decorative light of min. 6W of make C&S, Surya, Crompton or equivalent complete all as specified all as directedby Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified including testing after completion.
Notes :- (i) For Serial No 01 to 50, 57, 58, 79 to 91: The Contractor has to complete the work assigned for above items with in 36 hours failing in which recovery at the rate 25 Rs. per day per complaint. (ii) For Serial No 51 to 56, 59 to 78: The Contractor has to complete the work assigned for above items with in 60 hours failing in which recovery at the rate 25 Rs. per day per complaint. (iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell and get them signed from user after completing the job and submit to E/M complaint cell.
Shri Siddhi Vinayak Constructions
prabhave traders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .