STAFF OFFICER (ENM) OFFICE DUDHICHUA PROJECT NCL
STAFF OFFICER (ENM) OFFICE DUDHICHUA PROJECT NCL
Shifting of Existing East Substation and Installation and commissioning of 1 X10 MVA Power Transformer with Associated Electrical Equipment at the New Location near East Receiving Pit, East Section, Dudhichua Project
2026_NCL_369010_1
DCH/EnM/Tender/33KV/26-27/016 dated 14.11.26
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
STAFF OFFICER (ENM) OFFICE DUDHICHUA PROJECT NCL
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,400
16 Nov 2026
16 Nov 2026
28 Nov 2026
16 Nov 2026
27 Nov 2026
17 Nov 2026
16 Nov 2026 - 19 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | complete overhauling of 6.6KV, 1250Amp., VCB ( out door type) with control relay panel ( CT -03 Nos) Ratio 1000-500/1-1-1A, 60VA,class 0.2S, with Digital IDMT relay 3 over current and earth fault, shost circuit protection( current rating -1A/5A) Aux.Supply- 50 V- 300V AC and DC and earth leakage relay current range- 0.5A to 8A Time range-0-15 Sec, Aux. supply- 50V to 300 V AC and DC and PT -500VA, 6.6KV/110V 5 Limb , with required copper patti, bushing and studs | 1 | set | - | - |
| 2 | complete overhauling of 6.6KV, 1250Amp., VCB ( out door type) with control relay panel ( CT -03 Nos) Ratio 400-200/1-1-1A, 60VA,class 0.2S, with Digital IDMT relay 3 over current and earth fault, shost circuit protection( current rating -1A/5A) Aux.Supply- 50 V- 300V AC and DC and earth leakage relay current range- 0.5A to 8A Time range-0-15 Sec, Aux. supply- 50V to 300 V AC and DC and PT -500VA, 6.6KV/110V 5 Limb with required copper patti, bushing and studs | 2 | set | - | - |
| 3 | supply auxiliary switch 4NO-4NC for isolators interlocking | 6 | Nos | - | - |
| 4 | supply of CRCA sheet -1mm thick for making enclosures of AC, DC, lighting distribution Panels and isolators interlocking system | 21 | Kg. | - | - |
| 5 | Laying, erection, testing and commissioning of earthing arrangement/earth grid with bentonite earthing maintenance free arrangement with min.-30Kg MFC-20( Bentonite powder) and earthing electrodes with GI pipe 40mm dia and 3 mtrs. In length as secondary secondary electrode and 02 nos hot dipped GI strip size-25x6mm length 3 mtr as primary electrode and GI strip of suitable size for inter connection to form earth mesh, as per site connection for each earth pit | 16 | Nos | - | - |
| 6 | supply of GI earth wire 7/14SWG | 50 | Kg. | - | - |
| 7 | supply of GI earth wire 7/10SWG | 60 | Kg. | - | - |
| 8 | Supply of Aluminium Strip 60mmx6mm | 50 | Kg. | - | - |
| 9 | Panther ACSR conductor 200Sqmm | 200 | Mtr. | - | - |
| 10 | Post Insulator Porcelain 22KV | 24 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 1.68 MB
BOQ_382001.xls
BOQ • 0.29 MB
LOB.pdf
Tender Documents • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .