Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69,293.54Admitted-Fee/PreQual/Technical/Finance CHAKKALAKUNNAN H KURUMBALANGODE VILLAGE CHUNGATHARA MALAPPURAM DISTRICT | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹79,326.21+₹10,032.67 (14.5%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | ABDUL KAREEM L1 | BIJU C U L2 |
|---|---|---|---|---|---|
| 1.00Plumbing | |||||
| 1.00 | 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall | 15 | metre | 300.3 ₹4,504.5 Lowest | 343.84 ₹5,157.6 |
| 1.00 | 50.18.9.15.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall | 30 | metre | 383.12 ₹11,493.6 Lowest | 438.71 ₹13,161.3 |
| 1.00 | 50.18.9.5.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 | 40 | metre | 255.68 ₹10,227.2 Lowest | 292.78 ₹11,711.2 |
| 1.00 | 50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall | 11 | metre | 252.84 ₹2,781.24 Lowest | 289.53 ₹3,184.83 |
| 1.00 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | 4,000 | Litre | 9.96 ₹39,840 Lowest | 11.4 ₹45,600 |
| 1.01 | 18.49.1:Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore | 1 | each | 447 ₹447 Lowest | 511.28 ₹511.28 |
Tender Value
₹84,518
EMD Value
₹2,113
Closing Date
29 Sept 2026, 11:00 amClosed
AE Lsgd Panjal
Office of Assistant Engineer panjal gp
Annual Plan-Panjal GP 2026-27 Electrification and Plumping Works at Thozhuppadam GLP School
2026_LSGD_870943_6
02/26-27/AE/LIDEW/PJL
Open Tender
Civil Works - Buildings
Item Rate
Panjal
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹2,113
Yes
1 Oct 2026
22 Sept 2026
1 Oct 2026
22 Sept 2026
29 Sept 2026
22 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Plumbing | |||||
| 1.001 | 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall | 15 | metre | - | - |
| 1.002 | 50.18.9.15.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 10Kgf/cm2- External work- Exposed on wall | 30 | metre | - | - |
| 1.003 | 50.18.9.5.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2 | 40 | metre | - | - |
| 1.004 | 50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall | 11 | metre | - | - |
| 1.005 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | 4,000 | Litre | - | - |
| 1.006 | 18.49.1:Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore | 1 | each | - | - |
stage.html
html • 0.02 MB
finance_1476289.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.57 MB
affi.pdf
Tender Documents • 0.23 MB
epay.pdf
Tender Documents • 0.23 MB
fee.pdf
Tender Documents • 0.26 MB
fot.pdf
Tender Documents • 0.25 MB
ip.pdf
Tender Documents • 0.23 MB
prilims.pdf
Tender Documents • 0.25 MB
BOQ_1476289.xls
BOQ • 0.30 MB
sbd.pdf
Tender Documents • 1.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .