| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹34.3 L+₹3.6 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹37.3 L+₹6.6 L (21.6%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹38.3 L+₹7.6 L (24.7%)Rejected-Finance 17 NO TIKIA MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PGS KOLKATA 700120 WB | KOLKATA | 24 PGS | WB | 700120 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹40.6 L+₹9.9 L (32.3%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹30.2 L
EMD Value
₹60,400
Closing Date
7 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
CLEANING OF OHT AND UG SUMPS INLCUDING SOME ALLIED WORKS AND REPAIR/REPLACEMENT OF INTERNAL WIRING WITH CONNECTED ITEMS FOR ZONE B AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_473652_1
8544/E8
Open Tender
Civil Works
Item Rate
210 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹60,400
Yes
9 Nov 2021
8 Sept 2021
8 Oct 2021
8 Sept 2021
7 Oct 2021
30 Sept 2021
60 days
Amount
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for surface point wiring complete with two single core 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing and caping of size 20mm, ISI marked (medium grade) as required at site with all accessories such as Tee, corner, over laping, connector etc on walls / roofs / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for casing & caping entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of bakelite laminated top cover 3mm thick, blanking plate, numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed , single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces and applying white/ colour wash/distemper over applying putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches .
All as per Item No.2.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches .
All as per Item No.4.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
All as per Item No.4.00 here-in-before but point wiring with 4sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 10 Amps, 2way, single pole,1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular bell push, 10Amps, 1 module, single pole, 1 way, 240V, ISI Marked complete all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F for ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked as in repair complete all as specified and directed.
S&F for modular switch 10 Amps, 2way, single pole,1 module, 240V, AC, ISI Marked as in repair complete all as specified and directed.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked as in repair complete all as specified and directed.
S&F for modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular bell push, 10Amps, 1 module, single pole, 1 way, 240V, ISI Marked as in repair complete in repairs all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked as in repair complete all as specified and directed.
S&F for modular red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked as in repair complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC as in repair complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for switch socket combination, 6Amps, 5 pin, flush type, 2 in 1, 240 volts, ISI marked complete all as specified and directed.
S&F for switch socket combination, 6/16Amps, 6 pin, 240 volts, 2 in 1, ISI marked complete all as specified and directed.
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing as in repair complete all as specified and directed.
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed.
S&F for call bell ding-dong sound type, 230 Volts, 50 Hz, AC, ISI marked as in repair complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, buzzer type ISI marked complete as in repair all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F for switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked as in repair complete all as specified and directed.
S&F for switch socket combination, 6Amps, 5 pin, flush type, 2 in 1, 240 volts, ISI marked as in repair complete all as specified and directed.
S&F for switch socket combination, 6/16Amps, 6 pin, 240 volts, 2 in 1, ISI marked as in repair complete all as specified and directed.
S&F for switch socket combination, 6/16Amps, 6 pin, neon indicator type, 240 volts, ISI marked complete as in repair all as specified and directed.
S&F for batten holder /angle lamp holder, PVC/polycarbonate type, ISI marked as in repair complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Crompton as approved)
S&F for recess mounting 2'x2' LED 34/36 Watt light fittings with LED lamp and required driver, slim in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout modular ceiling grid and also can be suspended with provided kit and necessary electric connection with and including required size three coat sheathed flexible copper conductor cable from looping box to light fitting and testing complete all as specified and directed. (Make: Bajaj Cat No. BCTBLR 36W LED FP CW/Crompton Cat No.LCTLSNE-36-F0-CDL/ Havells Cat No.PLUTOSURFACE4X1PLS34WLED857S as approved)
S&F for decorative type surface mounted 1X6 watts LED light fitting with LED lamps including fixing arrangements at any height with nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of required size complete all as specified and directed. (Make: Crompton cat No.LCDEP-06-CDL / Havells cat No EDGEPRORDDLR6WLED857S as approved)
S&F for 70/72 watt LED secruity light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG as approved)
S&F for powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 8 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make: Legrand cat No.5077 32, 8 way / Hager Cat No.VYVO8DM-P / L&T Cat No.DBVTH008DD as approved)
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 8 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat as iafter and including taking down existing unserviceable DB complete all as specified and directed . (Make:- Legrand cat No. 5076 82 8 way / Hager Cat No.VYT08DH/ L&T Cat No. DBTPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make:- Legrand cat No. 5076 80 4 way / Hager Cat No.VYT04DH/ L&T Cat No. DBTPN004GD as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat after and including taking down existing unserviceable DB complete all as specified and directed . (Make:- Legrand cat No. 5076 20 4 way / Hager cat No.VYS04D / L&T Cat No. DBSPN004GD as approved).
S&F for suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts after and including taking down of unserviceable one complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed (Make: L&T /Havells/Legrand as approved)
S&F for MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCB, four pole, 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCCB, 100 Amps, 4 pole, 25KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz after and including taking down existing unserviceable MCCB complete all as specified and directed . (Make - L&T Cat No. CM91712OOKOOG /Legrand Cat No. 4200-55 /Hager Cat no. HHA101U as approved)
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of existing unserviceable submain wiring complete all as specified and directed. (Note : Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of existing unserviceable submain wiring complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down of existing unserviceable submain wiring complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
M&L for cleaning of existing RCC/PS/SMC over head tank (height of stagging upto 20 mtr from normal ground level) of capacity 150000 Gallon at Pump House No.3 complete having using the following steps during course of tank cleaning complete all as specified and directed:- (a) Dewatering of water by operating valves of any type and complete drain out of water from tank with the help of buckets and dewatering by pumps (if required) complete. (b) Cleaning of entire inside portion of Over Head Tank and removal of algae formation (if any) and iron sludge/slurry removal complete. (c) Scrubbing of the walls and floors and removal of all scaling algae and other formed particles on internal surfaces of the tanke completely. (d) Removal of all sludge/muddy water from the tank and complete cleaning of loose particles of any nature (second time cleaning). (e) Complete cleaning of inner surface of tank with fresh water and refilling with water to the tank after complete satisfaction of Engr-in-Charge. (f) Arresting/making good to the any minor repair (if any required) by applying cement mortar or chemical and to ensure no leakage from over head tank . NOTE: (i) Rates deemed to be included for writing date of cleaning with synthetic enamel paint having height of letters not less than 100mm with CA No. and Name of contractor. (ii) All safety equipments required and necessary insurance for safety working labour to execute the work is responsible of the contractor without any extra cost.
All as per item No 62.00 here-in-before but overhead tank (RCC) of capacity 100000 gallon at Pump House No.01, 02, 04 complete all as specified and directed.
All as per item No 62.00 here-in-before but overhead tank (RCC) of capacity 50000 gallon at Pump House No.05 & 06 complete all as specified and directed.
All as per item No 62.00 here-in-before but overhead tank (RCC) of capacity 10000 gallon at Jafarpur Range Pump House complete all as specified and directed.
All as per item No 62.00 here-in-before but inside semi-underground sump of any depth of capacity 300000 gallon at any height and locations complete all as specified and directed.
All as per item No 62.00 here-in-before but inside semi-underground sump of any depth of capacity 200000 gallon at any height and locations complete all as specified and directed.
All as per item No 62.00 here-in-before but inside semi-underground sump of any depth of capacity 5000 gallon at any height and locations complete all as specified and directed.
Cleaning and complete removal of all scales and dirts, silts etc, from tank and from mouth of circulating pipes etc for capacity of tank exceeding 500 litre & not exceeding 1000 litre including written as "Tank clean on DD-MM-YYYY" on the body of the tank with white paint complete all as directed by the Engineer-in-Charge.
S&F for ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed after and including taking out old unserviceable valve complete all as specified and directed for followings:-
Ball valve of size 20mm (minimum weight 210 gm)
Ball valve of size 25mm (minimum weight 455 gm)
S&F for sluice valve of size 150 mm , both end flanged with CI operating wheel, brass spindle etc as per latest IS specification, Class PN - 1.6 including necessary jointing and jointing materials such as gasket, nuts, bolts, washer etc complete after taking out old unserviceable sluice valve all as specified and directed.
S&F for sluice valve of size 100 mm , both end flanged with CI operating wheel, brass spindle etc as per latest IS specification, Class PN - 1.6 including necessary jointing and jointing materials such as gasket, nuts, bolts, washer etc complete after taking out old unserviceable sluice valve all as specified and directed.
Construction of valve pit chamber with brick masonary with sub class 'B' bricks (one brick thick) in cement mortar (1:6) and necessary PCC (75mm thick) type D2 (1:4:8) as in foundation and 15mm thick plastering on brick work in cement mortar (1:4) including necessary earthwork etc work having internal dimension 90cm x 90cm x 90cm and providing of 3mm thick MS sheet cover duly hinged on 40mm x 40mm x 6mm angle iron frame and embedded on top of chamber by minimum 4 Nos MS hold fast. Necessary locking arrangement shall be provided to the sheet cover for safety. The steel surfaces shall be painted with two coats black bituminous paint over a coat of anti corrosive red oxide primer complete after demolition of old valve pit chamber all as specified and directed.
M&L for CI specials any type spigot and socket ends or flanged pipe as required at site (such as bend, taper, Tee, socket etc) Socket end/ flanged as ordered of size up to 150mm after taking down old unserviceable CI specials (as per requirement of site to rectify the leakage)
Collecting the sample of water of required quantity in bottle/kit from different point submitted duly levelled the source through Engineer-in-Charge for forwarding to the test house and carrying out chemical testing of water for iron, PH value, hardness, turbidity, chloride, fluoride, arsenic test and submitting the test report in triplicate done from NABL & ISO 17025 accredited laboratory/ National Test House/Govt. approved laboratory complete all as specified and as directed. NOTE: Sample of water shall be collected and tested quarterly.
Collecting the sample of water of required quantity in bottle/kit from different point submitted duly levelled the source through Engineer-in-Charge for forwarding to the test house and carrying out bacteriological test for water sample quarterly and submitting the test report in triplicate done from NABL & ISO17025 accredited laboratory / National test house/Govt. approved laboratory complete all as specified and as directed. NOTE: Sample of water shall be collected and tested quarterly.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc and getting out in soft/loose soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
S&F for 50 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions pipes and fixed after taking down old unserviceable one complete all as specified and directed.
S&F for 40 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions pipes and fixed after taking down old unserviceable one complete all as specified and directed.
S&F for 25 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions pipes and fixed after taking down old unserviceable one complete all as specified and directed.
S&F for 20 mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions pipes and fixed after taking down old unserviceable one complete all as specified and directed.
S&F for 25mm dia GI tubings (medium grade) with all fittings laid in trenches after taking down old steel tubing and connection complete all as specified and as directed.
S&F for 20mm dia GI tubings (medium grade) with all fittings laid in trenches after taking down old steel tubing and connection complete all as specified and as directed.
Refixing old GI tubings (medium grade) with all fittings laid in trenches of 40 mm dia in old or new existing position after taking down old steel tubing and connection complete all as specified and as directed.
Refixing old GI tubings (medium grade) with all fittings laid in trenches of 50 mm dia in old or new existing position after taking down old steel tubing and connection complete all as specified and as directed.
Supply and charging of new life MnO₂ compound as per site requirement complete in all respect after taking out (unloading) the old catalyst (MnO2) from oxidation chamber with proper care complete and cleaning of pipes, Butterfly valve etc, of any capacity, flow, height by opening the manhole cover disconnection and including removing the waste material up to 50 mtr away from site spreading and leveling complete all as specified and directed by Eng-in-charge.
Supply, cleaning and filling the pressure filter sand (source: Barakar River) inside the pressure filter (type of sand 16/30 mesh) after removing of old unusable pressure filter sand complete all as specified and directed by the Engineer-in-Charge.
Supply, cleaning and filling the pressure filter gravel/filter media (source: Barakar River) of size upto 25mm after removing of old unusable filter media/gravel complete all as specified and directed by the Engineer-in-Charge.
S&F for LDPE double nut type strainers of iron removal plant as per site requirement complete including taking down old unserviceable strainers complete all as specified and directed .
S&F for mild steel nuts, bolts with washer as per site requirement including taking down old nuts, bolts etc complete all as specified and directed
S&F for gasket as per site requirements including taking down old gasket complete all as specified and directed.
M&L for preparing of outer surface (old) of iron removal filter plant of pressure feed filtration plant comprising of oxidation plant, iron removal plant, brine solution, softening plant of 20000 gallon capacity including all frontal pipes etc located at Pump House and applying one coat of synthetic enamel paint (as per existing color) with spray painting machine including arrow marking on inlet and outlet pipe line complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of inner surface (old) of iron removal filter plant of pressure feed filtration plant comprising of oxidation plant, iron removal plant, brine solution, softening plant of 20000 gallon capacity located at Pump house and applying one coat of anti-corrosive black bituminous paint suitable for drinking water complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of outer surface (old) of iron removal filter plant of pressure feed filtration plant comprising of oxidation plant, iron removal plant, brine solution, softening plant of 10000 gallon capacity including all frontal pipes etc located at Pump House and applying one coat of synthetic enamel paint (as per existing color) with spray painting machine including arrow marking on inlet and outlet pipe line complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of inner surface (old) of iron removal filter plant of pressure feed filtration plant comprising of oxidation plant, iron removal plant, brine solution, softening plant of 10000 gallon capacity located at Pump house and applying one coat of anti-corrosive black bituminous paint suitable for drinking water complete all as specified and directed by Engineer-in-Charge.
S&F for pressure gauge with fittings as per site requirement including taking down old gauge complete all as specified and directed.
S&F non-return (Reflux) valve size 100 mm with gun metal working parts, as per IS-5312, including jointing with rubber gasket, bolts, nuts, washer etc of following sizes complete as in repair all as specified and directed.
KOLAY CONSTRUCTION
M/S. ARUP KUMAR DEY
B N ENTERPRISE
M/S PAUL CONSTRUCTION
TAMALIKA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .