| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹16.6 LAccepted-AOC | L 1 | Accepted-AOC L1 after Negotiation | |
| 2 | L 2₹20.0 L+₹1.0 L (5.38%)Rejected-AOC | L 2 | Rejected-AOC L2 bidder | |
| 3 | L 3₹20.6 L+₹1.6 L (8.35%)Rejected-AOC | L 3 | Rejected-AOC L3 bidder | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹16.6 L
EMD Value
₹17,000
Closing Date
8 May 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Lucknow
work
2023_UPTCL_797411_1
e-tender 04/2023-24
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹17,000
7 Nov 2023
15 Apr 2023
10 May 2023
15 Apr 2023
8 May 2023
15 Apr 2023
Amount
(A) 220 KV BUS BAR REPLACEMENT WORK
1) Opening/cutting of R, Y &B phase of ACSR zebra jumper from 220KV existing Main Bus made of Tarantulla conductor between bus sections below gantries step by step during bus bar replacement work . also includes dismantling by all associated clamps/fitting .(1 job includes all 3 phases)
2) Dismantling of existing jumper of ACSR Zebra conductor of 200MVAT/F-I, II , B/C BAY, 220 KV Kursi road ,220 kv sarojini nagar, Jehta-I &II ckt feeder bay from Main bus bar by opening of all associated clamps step by step during Bus replacement. (1 job includes all 1 phase)
3) Dismantling of 220KV old main bus bar R,Y&B phase bus section of Tarantulla conductor and lowering down of conductor from substation gantry to complete dismantling works including dismantling all associated tension clamps &fitting to complete job satisfactorily. (1 job includes 1 phase)
4) Fixing/Erection of quadruple Moose suspension fitting under bus section of Main bus below gantries with suitable hardware such as hoisting disc insulators etc. to complete job satisfactorily. (1 job includes all 3 phases)
5) Stringing and proper sagging of New 220kv Main Bus bar (R, Y& B) by Twin Moose conductor the work includes fitting of tension clamps, hoisting of 120KN disc insulator tension fitting, spacers, ,P-G clamp, and cutting conductor as per requirements etc. to complete job satisfactorily. (1 job includes 1 phase)
6) Reconnecting of R, Y &B Phase of 220KV main bus bar of Twin Moose conductor between bus sections below gantries step by step during bus replacement including jointing of Zebra condctor below gantries with help of suitable PG clamps through quadruple suspension fitting &spacers etc, conductor cutting as per requirement.(1 job includes all 3 phases)
7) Reconnecting new jumper of ACSR Twin zebra conductor of 200MVAT/F-I, II , B/C BAY, 220 KV Kursi road ,220 kv sarojini nagar, Jehta-I &II ckt feeder bay of R, Y &B Phase of 220KV main bus bar of Twin Moose conductor between bus sections below gantries step by step during bus replacement including jointing of Zebra condctor below gantries with help of suitable PG clamps through quadruple suspension fitting &spacers etc, conductor cutting as per requirement.
8) Replacement of damaged jumper of ACSR zebra of different bays in 220kv switchyard after opening of damaged jumper & re-fixing of fresh jumper with help of fresh jumper with help of suitable PG clamps etc. and conductor cutting as per requirement.
9) Dismantling &lowering down of damaged 220KV Jack bus of ACSR zebra running over 6m Road connecting 245KV CB & Line isolator on either side for various bay namely- 200MVA T/F-I, II, Kursi Road bay, Sarojini nagar bay, Jehta-I, II feeder Bays using ACSR Zebra conductor including fitting of tension clamp, hoisting of Disc Insulator, cutting of conductor and also shifting of all materials from store to site.(1 JOB= 18 Mtr section of one Phase.)
10) Re-fixing/Stringing of fresh 220 KV Jack Bus of ACSR zebra running overhead of 6m Road connecting 245KV CB &Line isolator on either side of bay namely as- 200MVA T/F-I, II, Kursi Road bay, Sarojini nagar bay, Jehta-I, II feeder Bays using ACSR Zebra conductor including fitting of tension clamp, hoisting of Disc Insulator, cutting of conductor and also shifting of all materials from store site.(1 Section= 18 Mtr of one phases.)
11) Safe Carriage of 800 no. disc insulators from Various s/s to 220kv s/s Hardoi road, distance- 120km (Approx) using private truck including loading at 220kv Mohan road s/s and unloading at 220kv Hardoi road s/s using Hydra with required Manpower ,T&p in scope of contractor.
(B) Following Supply items are required for 220KV Bus Bar Replacement at 220 KV Sub station Hardoi Road, Lucknow
1) Supply of 220kv Bolted type single tension fitting suitable for Twin Moose conductor 1x16no. Disc insulator with Turn buckle ,D-socket, Ball hook ,yoke,plate, d-clip, tension clamp etc with duly made of LM6 aluminium alloy complete with GI nuts and bolt and spring/plain washer. As per technical specification
2) Supply of 220kv Bolted type single tension fitting suitable for Twin Moose conductor 1x16no. Disc insulator without Turn buckle ,D-socket, Ball hook ,yoke,plate, d-clip, tension clamp etc with duly made of LM6 aluminium alloy complete with GI nuts and bolt and spring/plain washer. As per technical specification
3) Supply of 132kv bolted type tension fitting for single zebra conductor 1x16no. Disc insulator complete with hardware fitting .as per technical specification.
4) Supply of 132kv bolted type suspension fitting for single zebra conductor 1x16no. Disc insulator complete with hardware fitting .as per technical specification.
5) Supply of 220kv bolted type suspension fitting for single zebra conductor 1x16no. Disc insulator complete with hardware fitting .as per technical specification.
6) supply of Spacers for Twin Moose conductor 250mm spacing as per technical specification.
7) Supply of Spacers for Twin Moose conductor 100mm spacing as per technical specification.
8) Supply of 4 bolted PG clamp duly made of LM6 aluminium alloy suitable for zebra-zebra complete with HDG GI nuts and bolt and spring/plain washer as per technical specification..
9) Supply of 4 bolted PG clamp duly made of LM6 aluminium alloy suitable for Moose to Moose complete with HDG GI nuts and bolt and spring/plain washer as per technical specification..
10) Supply of 4 bolted PG clamp duly made of LM6 aluminium alloy suitable for zebra- Moose complete with HDG GI nuts and bolt and spring/plain washer as per technical specification..
11) Supply of PG clamp duly made of LM6 aluminium alloy suitable for moose-panther complete with 4 no. 16x90mm size GI nuts and bolt and spring/plain washer. As per sample.
12) Bimettalic terminal connector for 160MVA HV side 220KV Bushing rod 60mm dia duly made of LM6 aluminium alloy suitable for zebra complete with HDG GI nuts and bolt and spring/plain washer as per technical specification & sample.
13) Bimettalic terminal connector for 160MVA LV side 132KV Bushing rod 60mm dia duly made of LM6 aluminium alloy suitable for moose complete with HDG GI nuts and bolt and spring/plain washer as per technical specification.. & sample.
14) Bimettalic 220KV Breaker clamp duly made of LM6 aluminium alloy suitable for zebra complete with HDG GI nuts and bolt and spring/plain washer as per technical specification.
15) Supply of Post insulator clamp for moose duly made of LM6 aluminium alloy with GI nuts and bolt and spring/plain washer. As per sample.
16) Supply of Post insulator clamp for zebra duly made of LM6 aluminium alloy with GI nuts and bolt and spring/plain washer. As per sample.
17) Supply of 220KV bushing palm clamp made of brass length 4inch hollow type with slots of dia as per dimension of bushing rod and other side plate with 4 no. holes for connecting clamp . As per sample.
18) Supply of 132KV bushing palm clamp made of brass length 4inch hollow type with slots of dia as per dimension of bushing rod and other side plate having 4 no. holes for connecting clamp.. As per sample.
19) Supply of 132KV bushing clamp made of LM6 aluminium alloy for zebra conductor with GI nuts and bolt and spring/plain washer. As per sample.
20) Supply of 3 Phase 3 pole 16 Amps. MCB of any Standered make
21) Supply of Auxiliary contactor relay 3 phase ,415volt,3NO+2NC any standard make
22) Supply of ON/OFF main 3 phase, MCB for fan rating -63 Amps,any standard make
23) Supply of NS type HRC fuse set rating-10 Amps
25) Supply of new generation energy saving environment friendly long life versatile pressure die casting aluminium outdoor high beam flood light with high power of LED street light luminaries 120 watt of havells/CGL /any standard make. Transportation upto site, insurance etc. and any other job requested to properly execute the complete work.
26) Supply of junction box on gantry structure of size 200mmx200x150mm made of MS sheet of 16 gauge duly powder coated in side fixing 1no. 6amp MCB ,1no. TB of 1no. terminal, and 1no. 16amp fuse fixed on MICA sheet and back side MS clampalong with PVC pipe fixing on junction box.half round GI PIPE OD 50mm for mounting the 120watt LED light upon gantry mounting of 02no. Bracket upon gantry and fixing GI pipe complete with Nut & bolts and washer.
27) Supply of half round GI PIPE OD 50mm for mounting the 120watt LED light upon gantry mounting of 02no. Bracket upon gantry and fixing GI pipe complete with Nut & bolts and washer.
Perfect Power Transformer Associates
M/S JAI SHREE ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .