Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.1 L+₹1.0 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Second Bidder |
Tender Value
Refer Docs
EMD Value
₹13,500
Closing Date
29 Apr 2023, 6:00 pmClosed
Major Sameer Wadekar
Holta Cantt Palampur
SPECIAL REPAIR T O GUARD ROOM IN BLDG NO P-15 AT FLAG STAFF HOUSE AT PALAMPUR MIL STN
2023_MES_575990_4
GEP-42/2022-23
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹13,500
Yes
6 Jul 2023
15 Apr 2023
1 May 2023
15 Apr 2023
29 Apr 2023
15 Apr 2023
Amount
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring,paver block and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm cut to size as required as in skirting/dado over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) 25mm thick as in sub base of flooring, leveling course of flooring or levelling course of roof etc, complete all as specified and directed.
M&L Non-skid, joint free (edge cut) coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and backing coat, and removing unserviceable materials,debris and rubbish to distance not exceeding 100m complete all as specified and directed.
M&L Glazed ceramic coloured tiles in vertical surface 350mm x 250mm x 7mm/450mm x 350mm x 7mm/450x300x7mm/600x300x7mm thick set and jointed in neat cement slurry, pointed in white or coloured cement to match the colour of tiles, over and including 10mm thick backing coat in CM 1:4 to receive tiles, complete all as specified and directed.
Taking down chowkats or frames with shutters (with out taking off shutter from the frames) exc 1.5 sq.m but n. exc 4 sq.m each, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n. exc. 1.5 sq.m each complete all as specified and directed.
S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, supplying and fixing in opening as per specifications and drawing complete all as specified and directed.
Factory made solid PVC moulded door shutters 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F pressed steel frames of size 165mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer,complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood rail and style plain framed, panelled shutter with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part 1) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick, 2nd class hard wood, factory made, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and directed.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS tube factory made with double side shutters wire gauged shutters & glass glazed shutter(wire and glass panes shall be measured and paid separately) with side hung shutters with steel handles and steel peg stay doytailed at welded incl 2 Nos tower bolts 150 mm long for each leaf and 8 mm square bar grills at spacing as shown on drg welded to FI frame work,incl other fittings,hinges,handles tarred hold fast PCC blocks etc. all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 ,complete all as specified.
S&F anodised aluminium frame for doors, windows, ventilators with minimum thickness of powder coating 50 micron with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated anodised aluminium window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. Note: Opening area of window/ventilator will be measured only and no leaf area will be measured.
S&F 100 mm size butt hinges (ISI marked), stainless steel complete all as specified and directed.
S&F 100 mm size (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F300 mm size (length of bolt) aluminium alloy, anodised, sliding door bolt with hasp and staple ,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 4mm thick plain sheet glass, oridinary quality and glazing with oil putty in squares n.exc. 0.50 sq.m in each pane, complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Dismantling of old rested plain or corrugated steel sheeting, any gauge, thickness,including Nainital or similar pattern roof covering etc. complete all as specified and as directed.
S&F 0.63mm Galvanised,corrugated mild steel sheeting with two corrugations side lap,fixed with L-type or J-type or cranked hook bolts and washers in roofs,walls etc. with grade of zinc coating 275 complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and weldling angles, as necessary, gusset plates, riveting et c., n.exc 10 Kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Dismantling of wall & ceiling boards (fiber, pulp, insulation etc) or insulation boards /slabs /blankets any thickness, including cover fillets complete all as specified and directed.
S&F 6mm thick E-board (classic) false ceiling of size 600x600 mm fixed in and including anodised aluminium snap grid frame work 605mm x 605mm for false ceiling including hangers 6mm dia GI(upto1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. flat iron of size 40mm X 3 mm, 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L preparation of new wooden surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two or more coats distempering with first quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre,of approved manufacturer,of required shade and colour complete as per manufacturer's specification over and including 2mm thick plaster of paris putty (JK/Birla Wall Care Putty) to prepare the surface even and smooth complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paints having VOC content less than 50 gms/litre, and UV resistance as per IS 15489-2004,alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additived @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90litre/10 sqm on new surface complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6, complete all as specified and directed.
M&L rendering 15mm thick plaster in cement mortar(1:4) on brick masonry wall surfaces or concrete surfaces finished even and smooth without suing extra cement complete all as specified and directed.
Rendering 10mm thick plaster in cement mortar 1:6 on fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. alslo splays between floors and beams, etc. complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate in footings, columns, plinth beam, roof beam etc complete all as specified and directed .
M&L reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Taking up or down 15mm bore steel water tubing and connections including cleaning for re-fixing, complete all as specified and directed.
S&F GI tubing (ISI marked) 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors (concealed tubing) complete all as specified and directed. Note:- The cost for cutting chases in walls,floors,etc and their making good for concealed pipe work included in this item.
S&F in repairs vitreous china, wash basin flat back, with pedestal white of size 550mm x 400mm including brass Chromium Plated waste coupling 32mm size with long screwed shank and fly nuts, flange end bedded in red lead cement,PVC medium grade 32mm size waste pipe, PVC connection 15mm size, 450mm long with PTMT nuts at both ends complete all as specified and directed.
S&F in repairs pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for 15 mm bore iron pipe complete all as specified & directed.
S&F in repairs, fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F in repairs 15mm bore stop valves/angle cock (two way if required), cast copper alloy fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union complete all as specified and directed.
S&F PVC connection 15mm size, 600 mm long with PTMT nuts complete all as specified and directed.
Dismantling of 110mm PVC (SWR)/cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches or walls or laid in floors complete all as specified and directed.
Dismantling of 75mm PVC (SWR)/cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches or walls or laid in floors complete all as specified and directed.
S&F 110mm bore of pipe PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to wall with clamps, floors, ceiling etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction (single T) equal or unequal complete all as specified and directed.
M&L 75 mm size cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 complete including taking down old unserviceable floor trap complete all as specified & directed.
S&F 75mm bore of pipe PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to wall with clamps, floors, ceiling etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) bends complete all as specified and directed.
Taking down roof trusses,coupled rafters or trussed beams clear span above 4.00m and upto 8m complete all as specified and directed.
M&L 50 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even & fair & filling the joints (6 mm wide) with mastic filling i.e one part of bitumen 85/25 or VG-30 and 3 parts of sand by weight complete all as specified & directed.
Supply, laying or passing through pipe XLPE cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sqmm, 4 core complete all as specified.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in any type of soil complete all as specified.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified.
Sand cushioning to underground cable as per clause No 19.75 of SSR Part-I laid with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 23 cm) complete all as specified.
Sub class “B” brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal, to length of the brick, complete all as specified and directed.
Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing as protection pipe for cable or as fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down of sub main wiring of any type and capacity with PVC casing caping / PVC surface or concealed conduit including earth wire and making good disturbed surfaces to match the existing surface, complete all as specified and directed.
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS-H cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including PVC surface casing & caping with accessories fixed wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for One light/ fan/ Exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and directed.
-Ditto- all as per serial item No. 72 above but one 5 pin socket outlet, 6 Amp on the same board complete all as specified and directed.
-Ditto- all as per serial item No. 72 above but one 5 pin socket outlet, 6 Amp on independent board complete all as specified and directed.
All as per Item No. 72 above but for 16 Amps socket point on independent board with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor as earth wire,complete all as specified and directed by Engineer-in-charge.
S&F switch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F socket outlets 2-in-1, 3 pin 6 Amp flush type, complete all as specified and directed.
S&F socket outlets 6 and 16 Amps 2-in-1, 5 pin flush type, complete all as specified and directed.
S&F switch piano 16 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F Ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and directed.
S&F Lamp holder with LED bulb 9W, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed.
Supply and fixing LED lights fitting 1x18 Watt, 240V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in repairs LED bulk head fittings IP-65 protection class with LED lamp 10 watt complete all as specified and directed.
S&F Factory made DB SPN 8 way double door with 200 Amps rated copper bus bar concealed in wall IP 42/43 protection,240V for fixing MCB complete all as specified and directed.
S&F MCB SP ‘B’ curve, 10KA 6 to 32 amps including necessary connection complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA 40 to 63 amps including necessary connection complete all as specified and directed.
S&F Factory made DB TPN 4 way double door with suitable size of copper bus bar concealed in wall IP 43 protection,415 V,3 phase 50 Hz for fixing MCB complete all as specified and directed.
S&F MCB TPN ‘B’ curve, 415V, 10KA 63 amps including necessary connection complete all as specified and directed.
M&L Wiring for circuit / sub-main wiring with approved colour coding in PVC concealed conduit alongwith 6 Sqmm earth wire with 2 x 6.0 Sqmm FRLS-H PVC insulated multi-stranded copper conductor, single core cable complete all as specified and directed by engineer in charge. Note:- 2 run of 6 sqmm wire and 1 run of 6 Sqmm of earth wire and PVC conduit shall be measured as one run.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
S&F PVC connection for hot and cold water, 15mm size, 450 mm long with PTMT nuts complete all as specified and directed.
S&F 15mm bore stop valves/angle cock, cast copper alloy fancy type chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union complete all as specified and directed.
S&F fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
M&L for cutting existing 20mm steel tubing for alterations or additions to connect 15mm bore GI tubing (Each cut measured) complete all as specified and directed. Note: Cost of connection and threading in 20mm bore GI tubing included in this item.
Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to galvanised iron earth lead wire 4mm (8 SWG) dia by means GI nuts, bolts & washers including PCC pit (1:2:4) type B 1 pre cast RCC cover slab of size 550 x 550 x 75mm thick using reinforcement with XPM weighting not less than 1.8 Kgs / sqmm with suitable handle, made of 12 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with case iton funnel and wire mesh, 15mm bore light grade galvanised steel tubing upto 5 M length for drawing earth lead wire protection, common salt, charcoal etc complete all as shown in EP No 3 of SSR Part I and testing on completion.
Disconnecting/taking down ceiling fan of size 1200mm/1400mm sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting oiling and greasing of bearing including refixing and making the connection and testing complete all as specified.
M/s Sai Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .